ISO-CART-85 Mobile Analysis System

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

ISO-CART-85 Mobile Analysis System image

ISO-CART-85 Mobile Analysis System

Product model:

Brief description:Complete in situ NDA gamma ray analysis solution

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

ISO-CART-85 Mobile Assay System IDM-200-V
Complete in situ NDA gamma ray analysis solution for a variety of samples, including decommissioned decommissioning waste
  • Measure all common geometries: pipes, cylinders, floors, ceilings, walls, barrels, bins and soil
  • Easy-to-operate cart for pushing on any surface
  • A wide range of collimators and shields are available to suit different measurement situations
  • Continuous height adjustment and variable angle adjustment
  • ISOTOPIC software whose results have been validated on thousands of real samples
  • Pre-calibrated at the factory or can be calibrated with an inexpensive mixed isotope point source
  • Flexible reporting: measurement results can be displayed in grams or activity (Bq or Ci)
  • information +

    • Download link ISO-CART-85 brochure
    • Download link ISO-CART-85 brochure (A4)
    • Download link ISO-CART-II Mobile Analysis System Assembly Guide
  • More information +


    ISO-CART-85 is a new mobile measurement system for radioactive waste analysis through high-resolution gamma spectroscopy. By using a single ultra-large area high-purity germanium (HPGe) detector and a modular collimation system, the ISO-CART-85 can achieve reasonable counting times at solution emission levels in many cases, making it suitable for field measurements.

    The HPGe detector is available as the ORTEC IDM-200-V, a revolutionary all-in-one integrated gamma spectrometer that does not require liquid nitrogen to cool to operating temperature. A micro Stirling cooler is used here. The built-in battery powers the cooler and highly stable digital signal processing electronics for up to 3 hours, and an external battery option or hot-swappable battery capability allows for extended battery life.

    The new system ISO-CART-II for mobile measurement is ORTEC's first generation of ISO-CART, which has been further enhanced based on operational experience and is also equipped with new options, such as a practical shield option for bottle containers, enabling the system to be used as a "field counting laboratory" for on-site measurement of large numbers of test samples. The ISOPLUS software has been tested in practice and its version is now compatible with 64-bit Windows operating systems.

    The ISO-CART-85 system is available "out of the box" and is traceably calibrated at our factory. Standard configuration includes:
    • ISO-CART-II。
    • IDM-200-V large-area, integrated HPGe spectrometer.
    • ISO-2-IDM-SHD modular collimator kit. Includes three field of view collimators (2", 4" and 6") and three 2" FOV collimator shields.
    • Install hardware
    • ISOPLUS waste analysis software.
    • Laptop with software installed
    • Factory calibrated.
    • All necessary cables and interfaces.

    For those who wish to use their own laptop, a "User Installed and Calibrated" version is available. If calibration is required but a laptop is not required, calibration files are available for users to install on their own computers. ISOPLUS software allows systems to be calibrated or recalibrated at any time using traceable point sources. Therefore, there is no need to return to the factory for recalibration.

    ISO-CART-85 Modular Collimator: The Lightest Weight Alignment Method
    System weight is a major consideration for mobile metrology systems, which by definition must be able to move. The operation of the ISOPLUS software is based on the assumption that the detector "observes" representative material of the measured object through a defined "field of view" and then determines the total material on this basis. This requires the detector to be equipped with a collimator to limit and define a suitable field of view that is representative of the sample. Another consideration is that the detector itself may be exposed to external radiation from sources other than the object being measured (such as from other nearby waste samples). This may require the use of thicker collimators. For this reason and to ensure minimum weight, a modular collimator system was designed that improves upon a thinner, low-Z material-lined field collimator with additional detector shielding and thicker collimation required for background radiation.

    The ISO-2-IDM-SHD kit includes three 15 mm thick, thin-walled steel, Sn/Cu-lined field of view collimators in 2", 4", and 6" lengths to provide different fields of view, and three 2" deep, 1" wall, lead cross-section shields for the FOV collimators (ISO-2-IDM-SHD-2). Selecting the appropriate field collimator and then adding additional shielding as appropriate ensures minimum weight.

    ISO-CART-85 Bottle Sample Shield Extension Option: "On-Site Counting Lab" No Return to Base Required
    In mobile analytical applications it may sometimes be necessary to collect a small sample of contaminated material (e.g. soil) and then analyze it in the "usual" measurement geometry (i.e. inside a lead shield), e.g. for screening purposes, to determine if the material is contaminated below the detection limit of collimated detection. The ISO-CART-85 shield extension can be mounted on an upward-facing 6-inch modular collimator and three 2-inch lead shields to form a small counting shield, allowing measurements of 1-liter bottle containers directly on the detector end cap, in an efficient measurement geometry.

    ISO-2-IDM-SHD-EXT option includes shield extension for ISO-2-IDM-SHD, and six 1-liter bottles. Pre-calibrated ISO-CART-85 systems can be used directly with this option.
  • Ordering information +


    Model

    Description

    ISO-CART-85-PC

    completeISO-CART-85System, factory calibrated. includeISO-CART-II, used forIDM-200-VofIDM-200-V-ISO-2-DCCdetector-Collimator bracket,ISO-2-IDM-SHDModular collimator,IDM-200-VIntegrateHPGespectrometer,ISOPLUS(ISOTOPIC) software,ISO-CALPoint source factory calibration and laptop with software installed (printer not included).

    ISO-CART-85-NOPC

    Not includedPCor factory calibratedISO-CART-85system. includeISO-CART-II, used forIDM-200-VofIDM-200-V-ISO-2-DCCdetector-Collimator bracket,ISO-2-IDM-SHDModular collimator,IDM-200-VIntegrateHPGespectrometer andISOPLUS(ISOTOPIC) software.

    ISO-2-IDM-SHD-EXT

    used forISO-2-IDM-SHDExpansion options. include6a1Liter bottles.

    individual components

    ISO-2-IDM-SHD

    used forIDM-200-Vmodular collimator kit including
    1
    aISO-2-IDM-FOV-2 2inch steel field collimator
    1
    aISO-2-IDM-FOV-4 4inch steel field collimator
    1
    aISO-2-IDM-FOV-6 6inch steel field collimator
    3
    used forFOVcollimatorISO-2-IDM-SHD-2 2inch deep lead section shield.

    ISO-CAL

    Factory point source calibration (if not orderedPC, documents will be provided separately)

    ISO-CART-II

    Cart only. (Detector/Collimator Carrier (DCC) not included)

    IDM-200-V-ISO-2-DCC

    used forIDM-200-Vdetector-Collimator bracket

    ISO-2-IDM-FOV-2

    2inch steel field collimator forIDM-200-V,Sn/CuLining

    ISO-2-IDM-FOV-4

    4inch steel field collimator forIDM-200-V,Sn/CuLining

    ISO-2-IDM-FOV-6

    6inch steel field collimator forIDM-200-V,Sn/CuLining

    ISO-2-IDM-SHD-2

    used forFOVcollimator2inch deep lead section shield.1inches wall thickness

    IDM-200-V

    integratedHPGespectrometer

    ISOPLUS-BW

    ISOTOPICWaste Measurement Analysis Software