583B Constant Fractional Differential Discriminator/Single Channel Analyzer
Product model:
Brief description:Constant fractional timing with fast SCA pulse height selection Excellent time resolution over a wide range of pulse amplitudes with scintillation and semiconductor detectors Differential, integral, constant fractional and slow rise time rejection modes High and low level thresholds adjustable from -30mV to -5V Within 100:1 dynamic range

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- Solid water phantoms are available in a variety of standard sheet thicknesses
- Application of radiotherapy three-dimensional water tank in radiotherapy
- Do you know how to use nuclear radiation detectors?
- Radiation meters protect environmental safety: Popular science on the application of practical equipment for radiation monitoring
- Application scenarios for low-contrast detail detection phantoms
- Important equipment for radiation environment monitoring: A brief analysis of the application of KARRAY neutron dose rate meter
- Thermoluminescent personal dosimeters can be used in areas such as environmental dose monitoring
- Low-contrast detection phantom to protect health
- Surface contamination detector: Analysis on the application of important auxiliary equipment in radiation environment monitoring
- Personal dose alarm brand analysis: Garry’s technical strength and market performance
Detailed introduction

- Constant fractional timing with fast SCA pulse height selection
- Excellent temporal resolution over a wide range of pulse amplitudes in conjunction with scintillation and semiconductor detectors
- Differential, integral, constant fractional and slow rise time rejection modes
- High and low thresholds adjustable from -30 mV to -5 V
- Time walk ≤±75 ps over 100:1 dynamic range
- Adjustable output pulse width
The ORTEC Model 583B Constant Fractional Differential Discriminator is a versatile, high-performance device suitable for applications in the field of timing spectroscopy.