KARRAY / PRODUCT DETAILS

ASPEC-927 Dual Input MCB

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

ASPEC-927 Dual Input MCB image

ASPEC-927 Dual Input MCB

Product model:

Brief description:Dual fast (1.25s) ADCs and memory dual 16kADCs in single-wide NIM

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

ASPEC-927 Dual Multichannel Buffer
  • Dual fast (1.25 μs) ADC and memory in single-width NIM
  • Dual 16k ADC, compatible with MAESTRO MCA emulator for Windows
  • Live time corrections, including ZDT
  • PUR, BUSY (busy) and GATE (gate) input terminals
  • USB-2.0 interface
  • True real-time data display
  • This device can be synchronized with an autosampler or process control
  • Onboard memory can be quickly downloaded to your PC
  • Two inputs on single-width NIM

ORTEC ASPEC-927 model is connected to a personal computer via USB-2.0 interface and comes with MAESTRO simulation software. Each ASPEC-927 is housed in a single-wide NIM chassis with two independent 16k ADCs and 512 kb of memory. The successive-approximation 16,384-channel ADC with 1.25 μs conversion time offers a choice of conversion gain settings of 8,192, 4,096, 2048, 1024, or 512. Dead time correction can be accomplished using the Gedcke-Hale extended live time method or the ZDT method.

A single computer subject to the USB-2.0 data transfer speed can control multiple devices using a USB-2.0 hub.
  • information +

    • Download link ASPEC-927 Brochure
    • Download link ASPEC-927 Brochure (A4)
    • Download link ASPEC-927 Manual
  • Specifications +


    Performance

    ADC

    Successive approximation type with sliding scale linearization.

    resolution

    16k: 16,384channels, software selectable16,384、8,192、4,096、2048、1024and512。

    Dead time for each event

    2 μsIncludes memory transfer.

    integral nonlinearity

    before the dynamic range99%,<+0.025%。

    differential nonlinearity

    before the dynamic range99%,<±1%。

    gain instability

    <+50 ppm/°C。

    Dead time correction

    The software can be based onGedcke-Halemethod orZDTLive Time Correction Performs an extended live time correction that monitors the count rate and adjusts for dead time for count rate fluctuations.

    data memory

    512 kb。

    USBinterface

    PassUSB 2.0Connect toPC. The data transfer speed is480 Mbps。

















    input and output

    Input

    Accepts positive unipolar, positive gated integrator, or0to+10 VBipolar analog pulses that are predominantly positive within the dynamic range;+12 V;0.25Arrive30 μsThe semi-Gaussian time constant of3Arrive30 μsthe time constant of the gated integrator shape, or the delay line shape, where the width>0.25 μs。Zin =1kΩ, DC coupled. No internal delays,BNCconnector.

    ADCdoor

    OptionalTTLEnter. The computer can choose conform mode, anti-conform mode, or off. The signal must occur before and exceed the pulse peak0.5-μs;BNCconnector.Zin= 1kΩ。

    PUR

    Stack rejection input; acceptTTLSignal; the signal must occur before peak detection.Zin= 1kΩ。BNCconnector.

    busy

    Busy input used by the live time correction circuit. acceptTTLSignal; the signal must occur before peak detection.Zin= 1kΩ。BNCconnector.

    Changer input

    9needle"D" type connector.Zin= 1kΩ。ADC 1The input is the pin1。ADC 2The input is the pin5. Ground is the pin9。

    Sample conversion output

    9needle"D" type connector.Zout= 1 kΩ。ADC 1The output is a pin3。ADC 2The output is a pin7. Ground is the pin9。

    USB-2.0

    StandardUSBConnection is via the included10ft. of cable implemented.


    indicator

    ADC1

    instructionsADC-1activity.

    ADC2

    instructionsADC-2activity.





    Software control
    (Use the includedMAESTROperform operations - See datasheet for details. )

    ADC LLD

    The computer can be accessed from0Arrive100% of full scale for control.

    ADC ULD

    The computer can be accessed from0Arrive100% of full scale for control.





    Default

    real time/living time

    20Multiple of milliseconds.

    area of interest

    Peak count/Points counting.

    Data overflow

    When any channel exceeds231-1Data collection will be terminated.

    peak uncertainty

    Acquisition stops when the statistical or counting uncertainty of the user-selected net peak reaches a specified value.

    nuclideMDA

    When the user specifiesMDAThe minimum detectable activity (MDA) value reaches the specified value, data collection will stop.

    live time correction

    Gedcke-Hale,ZDT。

    door

    Conform, anti-conform, close.















    electrical and mechanical

    Required power supply

    +6 V, 250 mA; +12 V, 165 mA; -12 V, 165 mA。

    weight

    Net weight 0.9Kilogram (2pounds).Shipping weight 2.25Kilogram (5pounds).

    Size

    NIMStandard single width3.43 x 22.13cm (1.35 x 8.714inches) front panel, conforming toDOE/ER0457Trequirements.








  • Ordering information +


    Model

    Description

    ASPEC-927

    single widthNIMmiddle pair16k ADC. includeMAESTROand10feetUSBinterface cable.

    927-OPT1

    for sample changerI/Ofemale headBNCAdapter cable. This option provides cable connections to the input and output of the sample converter.

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7