EASY-MCS multi-channel scaler

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

EASY-MCS multi-channel scaler image

EASY-MCS multi-channel scaler

Product model:

Brief description:Well-suited for: Time-resolved single-photon counting phosphorescence lifetime spectroscopy measurements Atmospheric and satellite LIDAR Laser-induced chemical reactions Scanning mass spectrometers Time-of-flight spectroscopy systems Scanning X-ray diffractometers Mössbauer experiments EASY-MCS is a compact instrument

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

ORTEC EASY-MCS Multichannel ScalerGreat for:
  • Time-resolved single photon counting
  • Phosphorescence lifetime spectrum measurement
  • Atmospheric and satellite LIDAR
  • Laser-induced chemical reactions
  • scanning mass spectrometer
  • time of flight spectrum system
  • Scanning X-ray Diffractometer
  • Mössbauer experiment

EASY-MCS is a compact instrument that comes with software that converts the instrument into a powerful and flexible multi-channel scaler (MCS) or multi-stop time spectrometer when connected to a personal computer via USB 2.0 interface. Advanced software running under Windows enables all controls and spectral operations from the screen. Resident memory provides access to spectral data for display purposes without interrupting EASY-MCS data acquisition. With dwell times from 100 ns to 1300 s, memory length of 65,536 channels, and input count rates up to 150 MHz, EASY-MCS can flexibly handle a variety of counting and time measurement applications.
  • information +

    • Download link EASY-MCS brochure
    • Download link EASY-MCS Brochure (A4)
    • Download link EASY-MCS Manual
  • More information +


    Main features

    Hardware

    • The time width of each channel is selectable from 100 ns to 1,300 seconds
    • Number of channels per scan selectable between 4 and 65,536
    • Fast analog input accepts count rates up to 150 MHz
    • 1 MHz single-channel analyzer input with computer-controlled high and low level discriminators, independently adjustable from 0 to +10 V
    • Computer-adjustable discriminator thresholds for fast analog input and external channel advance input
    • Zero dead time between lanes: no counts are lost and no counts are repeated at lane boundaries
    • No "pass through" dead time
    • Sum mode for signal averaging; replace mode for single scan data; replace first then sum mode to avoid reset dead time between acquisitions
    • Up to 1,073,741,823 counts per channel in single or multiple channels
    • Automatically terminate data collection after a preset number of passes (up to 4 billion)
    • A scan start can trigger an experiment, or an experiment can trigger a scan start.
    • Includes ramp output with computer-adjustable sawtooth and triangle waveforms

    Software

    • Equipped with operating, display and analysis software
    • All functions can be controlled by computer
    • SCA scan mode for recording pulse height spectra and selecting accurate SCA windows
    • Spectra and instrument settings can be saved to disk and recalled later for further processing
    • Software features include smoothing, summing, stripping, comparing and normalizing spectra; peak searches, reporting and user-defined workflows
    • Calibrate results to user-defined units via least squares fit
    • A11 Programmer's Toolkit for ActiveX™ programming under LabVIEW®, Visual Basic or Visual C++

    Rich time range selection
    EASY-MCS uses a crystal-controlled clock with 100 ppm accuracy and high-speed digital electronics to achieve a wide range of precise operating parameters. Since the time width of each channel can be selected from 100 ns to 1300 seconds and the scan length can be varied from 4 to 65,536 channels, the time scan can be selected from 400 ns to 2.7 years.

    No dead time between lanes, and zero "pass through" dead time
    EASY-MCS uses sophisticated digital circuitry to eliminate inter-channel dead time typically encountered in low-performance multichannel scalers. There are no lost counts and no double counting as the multichannel scaler advances from one time channel to the next. Fast digital processing also ensures there is no dead time passing through before starting a new scan.

    Multi-function counting input terminal
    Two different types of counting inputs make the EASY-MCS suitable for almost any signal source. The fast analog signal input (IN) accommodates analog and digital signals with pulse widths >3.5 ns and count rates up to 150 MHz. The input discriminator threshold is computer adjustable from -⁠1.6 V to +3 V in 1.5 mV steps (pulse amplitude must be >30 mV). This facilitates prioritizing larger pulses for counting and noise suppression. Positive slope or negative slope triggering can be selected to match pulses of either polarity.

    For positive analog signals with count rates up to 1 MHz, EASY-MCS provides pulse amplitude selection on the SCA input. This "single-channel analyzer" has two computer-controlled discriminators at the input, with thresholds programmable between 0 and +10 V and a resolution of 12 bits. EASY-MCS only counts analog pulses that are above the low threshold but not above the high threshold. This input is ideal for analog signals whose amplitude is proportional to a measured parameter, such as the number of photons in the pulse. Pulse widths from 0.5 to 100 μs can be easily accommodated.

    Features* SCA scan mode
    SCA scan mode sets SCA thresholds quickly, easily, and accurately. In this mode, the width of the window between the lower and upper SCA thresholds remains constant (1/512 of 10 V), while the computer repeatedly scans the position of the window from 0 to +10 V in 512 equal steps. When synchronized, the multichannel scaler repeatedly scans channels 0 through 511 while counting the SCA outputs. The result will show the pulse amplitude spectrum at the SCA input. The mouse can be used to mark the lower and upper limits of spectral features on the screen for selective counting in subsequent multichannel scaler mode. After marking these limits, clicking the Set SCA button on the display locks SCA's lower and upper thresholds into the precise settings that support that feature.

    Improve accuracy through signal averaging
    For any selected dwell time and storage length, the data collected in each scan can replace, or be added to, the data stored in memory. The latter mode can be used to reduce statistical scatter. It effectively improves the signal-to-noise ratio through signal averaging. For random noise (noise not correlated with the start trigger or dwell time clock), the signal-to-noise ratio improves proportionally to the square root of the number of scans added together. Select Preset Pass Count to set up the instrument to collect data for the desired number of scans (or passes) and then automatically stop data collection. After data collection begins, the computer is free to run other software programs. To allow repeated addition of data with high accuracy, the preset number of passes can be set to any value between 1 and 4,294,967,295, with a memory capacity of 1,073,741,823 counts per channel.

    Multifunctional scan synchronization
    EASY-MCS provides two methods for synchronizing scans at the start of an event for a desired count. The start of a scan in EASY-MCS can trigger an event (internal trigger mode), or an external trigger of an event can start a scan (external trigger mode).

    internal trigger mode
    The start output is a 160 ns wide positive TTL signal generated synchronously with the start of the scan. This output can be used to trigger external events. For example, this signal can trigger a laser, whose output light pulses can be used to excite phosphorescence in the sample. After each laser pulse, the decay count rate of photons emitted by the sample is counted by EASY-MCS.

    For measurements that require analog control parameters (e.g., Mössbauer experiments), EASY-MCS provides a ramp output voltage proportional to the number of channels in the scan. The ramp can be operated with a zigzag pattern or a triangular waveform. In sawtooth mode, the ramp voltage changes linearly from the start voltage to the end voltage as the scan progresses. At the end of the sweep, the voltage quickly changes back to the starting voltage. For the triangular pattern, the ramp voltage changes linearly from the starting voltage to the midpoint voltage during the first half of the scan. During the second half of the sweep, it makes another linear transition from the midpoint voltage to the end voltage. All three voltages (start, middle and end) are computer adjustable from 0 to +10 V (65,536 steps). To achieve precise repeatability, the ramp curves are stored as digital images in half of the memory. This limits the storage length available for counting events to 32,768 channels when ramping is active.

    External trigger mode
    In external trigger mode, a positive TTL logic pulse sent to the start input will start a scan in EASY-MCS. Scanning can be based on the internal dwell time clock in EASY-MCS, or channel advancement can be achieved by providing pulses to the channel inputs.

    When using the internal dwell time, scanning begins on the edge of the internal 50 MHz clock after the rising edge of the start input pulse. When using external channel advance, scanning begins after the rising edge of the enable input and when the rising edge of the channel advance input pulse exceeds its discriminator threshold. The external channel advance input includes a computer-controlled discriminator threshold selectable from -1.6 V to +3 V in 1.5 mV steps (pulse amplitude must be >30 mV). This discriminator can accommodate a variety of signal sources at the forward input of the external channel. The minimum interval between external channel advance pulses is 100 ns.

    Instrument control with a single mouse click
    EASY-MCS software running under Windows provides a comprehensive graphical user interface for spectral data display and instrument control. All controls can be activated instantly on the computer display via the mouse. The control is always displayed next to the spectrum. Less commonly used setup parameters are easily accessible from drop-down menus. In addition to quick operations using the mouse, most controls can also be activated via keystrokes. To protect against power outages, all control settings are automatically stored on the hard drive when the scan begins. In addition, settings can be saved in a file so that specific operating conditions can be recalled later.

    Quick access to multiple spectra
    On-screen controls allow the operator to view spectra acquired in the EASY-MCS dual-port memory, or previously transferred to the computer's buffer memory. All functions related to display and operation can be applied to any of these stored spectra. Spectra can also be saved as disk files for later recall and inspection, or further processing.

    Full and extended display of quantitative details
    Two views of the selected spectrum are displayed. The box in the upper right corner always shows the complete spectrum. Areas selected and marked on this small screen will expand in the larger screen, allowing for better resolution of details. By using the mouse pointer, markers can be moved across the spectrum to features of interest. At the same time, the computer displays the horizontal coordinates of the channel specified by the marker location, as well as the number of counts recorded in that channel. By default, horizontal coordinates are displayed as channel numbers in external dwell time mode. In internal dwell time mode, the default horizontal coordinate corresponds to the selected dwell time. Horizontal scales can be easily calibrated to user-defined units by least squares fitting to linear, quadratic, or cubic functions. In this case, the mark position will be read in calibrated units. Once calibration is complete, operators can quickly switch between default and calibrated units.

    This marker is also used to draw "regions of interest" (ROIs) on the spectrum. Typically, this is a colored area that marks the entire area under the peak of the spectrum. Single or multiple ROIs can be marked in the spectrum. By using the Data Info command under the Calculate menu, markers can be positioned within the ROI to trigger the computer to display the center tract of the ROI, the total counts in the ROI, and the net counts in the peak above background.

    More analysis options
    Further software features allow the operator to compare two spectra, subtract or add two spectra, normalize the vertical scale, subtract a flat background or smooth statistics. Additionally, a routine is provided that automatically finds each peak in the spectrum and labels it with an ROI. Center lanes, total counts, and net counts can be printed for all ROIs in the spectrum with or without library matching. If the computer is asked to match a user-defined library of peak locations, the library information will be printed along with the matching ROI data. In addition to the standard .MCS file format, spectra can be imported and exported as ASCII text.

    Programmed data collection
    Some measurements require changes in data acquisition conditions due to the acquisition of different spectra. The Start Job command under the Services menu provides operators with an easy way to define a flow of job commands that change instrument settings and control multiple spectral acquisitions. Job flows can be simple or complex. Once a job flow is defined and implemented, data collection occurs automatically under job control.

    Other software programs can activate EASY-MCS to perform specific operations by calling the EASY-MCS software using the job file name specified on the command line. Alternatively, the A11 CONNECTIONS Program Development Kit can be purchased for programming EASY-MCS at the command level. Programming with LabVIEW®, Visual Basic, or Visual C++ becomes even easier with ActiveX™ controls in A11.

  • Specifications +


    Performance

    Count rate

    INThe connector is150 MHz;SCA INThe connector is1 MHz。

    Discriminator Threshold (INandCHN ADV IN)

    Software control and variation range is-1.6 Vto+3 V, the step size is1.5 mV(The pulse amplitude must>30 mV). Trigger on selectable fast analog signalsINPositive or negative slope on the connector. The external channel advance input triggers on positive slope only.

    SCA IN

    The upper and lower thresholds can be obtained from the computer0Arrive+10 V(12bit resolution) are selected independently.

    residence time

    internal clock The dwell time of each channel can be selected by computer
    • 100 nsto1.3 ms, the step size is20 ns,
    • 1.3 msto1.3 s, the step size is20 μs,
    • 1.3 sto1300 s, the step size is20 ms。

    Accuracy: ± over operating temperature range100 ppmWithin.

    External clock input External channel advance input (CHN ADV IN) determines the stay time. The minimum external dwell time for each channel is100 ns。

    Channel width uniformity

    For the worst case scenario100 nsDwell time, system dwell time variation over the entire pass length<0.1%。

    through length

    The number of time channels in a single pass is computer selectable, with ramps on the range is4Arrive32,768, the range when the slope is closed is4Arrive65,536。

    by preset

    The instrument can be programmed to stop data acquisition after a preset number of scans. By default, you can1Arrive4,294,967,295Choose between or be turned off.

    Memory capacity

    per channel1,073,741,823count (30bit).

    Acquisition mode

    SumThe data set from each pass is added to the sum of the data sets from the previous passes.
    replaceThe currently passed data set replaces the last passed data set.
    replace/SumData acquisition runs in substitution mode on the first pass and then switches to summation mode for subsequent passes. This eliminates the need to clear memory between acquisitions and reduces the need forEASY-MCSDead time when collecting data alternately between two devices.

    Count in single pass/channel

    1,073,741,823

    dead time between channels

    There is no dead time between lanes, i.e. no counts are lost as the lane advances. Events are always counted in only one of the adjacent channels.

    by ending dead time

    During acquisition, there is no dead time between passes.

    Ramp output

    Linear ramp whose "start", "middle" and "end through" voltages can be programmed by computer at0to+10 VSelect within the range, with a resolution of16bit, the establishment time is2 μs。


    Computer controls and indicators
    The following controls and indicators consist of drop-down menus on a software-generated control panel or computer display. These functions are conveniently selected and activated using the mouse, but can also be accessed via keystrokes.

    Collect

    start

    A button is displayed that initiates data acquisition synchronized to the next internal clock pulse.

    stop

    Click the displayed button to stop data collection at the end of the current pass. Clicking again will immediately stop data collection

    Clear

    The Display button clears the spectrum data and pass counts (buffer orMCSmemory).

    Pass

    Displays the current pass or scan number (1Arrive4,294,967,295)

    Default

    Displays the preset pass number that will terminate data collection.

    channel

    Displays the channel number into which the current count is accumulated, starting from the channel0Start.

    through length

    Displays the number of channels selected for length.

    stay

    Displays the selected dwell time for each channel.
















    View

    MCS#

    During or after acquisition, select theMCSnumber. The software supports up to8TaiwanEASY-MCSequipment. To be on onePCView multiple channels at the same timeEASY-MCSdevice, the software must be opened multiple times.

    buffer

    WhenMCSWhen the next spectrum is collected, a button appears to select buffer memory in the computer to view previous spectra.

    Horiz

    Indicates the number of channels to view in the larger extended spectrum, and the width of the window in the small full-size spectrum screen. The arrow buttons shown are used to expand or contract.

    Vert

    Indicates the number of counts in the vertical scale currently selected for large extended spectra. The arrow buttons shown are used to change the scale.

    Log

    Buttons appear to select a logarithmic vertical scale for large extended spectra.

    Lin

    Buttons are shown to select a linear vertical scale for large extended spectra.

    automatic

    Buttons appear to automatically adjust the vertical scale and center the window around markers on the large screen for easier viewing of the spectrum.

    mark

    A vertical line can be dragged left or right across the screen with the mouse. The vertical coordinate of the data (counts) at the marker location is shown to the right of center under the large spectrum. Horizontal coordinates are shown left of center below the spectrum. The horizontal scale is based on time and channel number (Chan) or any unit representation selected during horizontal scale calibration. Markers can be used to mark regions of interest and read out the peak centroid and total or net peak area within each region of interest.

















    input control

    UseSCAInput

    Show button enablesSCAInput usage. seeSCAandSCA IN。

    UseDiscInput

    The Show button enables use of the quick discriminator input. See discriminator andIN。

    SCA: low, high

    The two displayed sliders can be0Arrive+10 V(4096Independent selection between steps)SCALow and high thresholds. seeSCA IN。

    discriminator

    The slider displayed can beINconnector in-1.6 Vto+3 VSelect the discriminator threshold between1.5 mV(The pulse amplitude must>30 mV). Two displayed buttons select discriminator cross counting on rising edges (positive slope) or falling edges (negative slope). Two displayed buttons select the input impedance:50Ω or1kΩ. seeIN。













    SCA
    Scan control

    This control provides an optionSCAEfficient way to set up without using an oscilloscope. WhenMCSscan512When the passage length of a channel isSCAwindow (having between high and low levels19.5 mVwidth) from0Scan to+10 V. The resulting histogram will showSCAPulse height spectrum at the input.

    By using the cursor to mark the area above the feature of interest in the spectrum and clicking SetSCA” button,SCAThe levels will automatically be set to the upper and lower limits of the selected zone. This is for regularMCSScan settingsSCAA fast and accurate method. A single pulse height scan usually lasts5Arrive20seconds, depending on the speed of your computer. To improve count statistics in histograms, scan when acquisition is stopped or setSCAThe level will automatically repeat before.








    via controls

    Collection mode: sum, replace, replace/Sum

    Different modes of data collection are available via3Select one of the displayed buttons. See Acquisition Mode under Performance.

    Trigger: internal, external

    Two displayed buttons are used to controlMCSWhether the start output of the external instrument will trigger the start of each scan (internal trigger), or whether the start input of the external instrument will start each scan (external trigger).

    through length

    Data entry box with upper part for adjustment/down arrow, available at4Arrive32,768between (when ramp output is active) or between4Arrive65,536Select the number of channels in a single pass (sweep) between (when ramp output is disabled).

    Preset by count

    Data entry box with upper part for adjustment/Down arrow to select the number of passes to be performed before data collection automatically stops. Available at1Arrive4,294,967,295Choose between passes, or turn off to disable.

    stay

    Two displayed buttons select internal dwell time clock or external channel advance input. The Width data entry box provides a range of internal dwell time choices. See Dwell Time under Performance. Data input boxes can1.5 mVThe step size advances the external channel input threshold from-1.6adjust to+3 V(The pulse amplitude must>30 mV)。














    ramp control

    style:start - end, start - midpoint - end

    Two buttons are displayed to select a single or two-stage ramp. The single-segment ramp moves linearly from a specified starting voltage at the beginning of each pass to a specified end voltage at the completion of each pass. The two-segment ramp linearly transitions from a specified starting voltage at the beginning of the pass to a specified midpoint voltage at the midpoint of the pass. It then transitions linearly from the midpoint voltage to the specified end voltage at the completion of the pass.

    start, midpoint and end

    The three displayed sliders can be accessed from0Arrive+10 VSelect the starting point, midpoint and endpoint ramp voltage with a resolution of16Bit.







    drop down menu

    Clicking the menu title at the top of the display generates a drop-down menu that provides access to other screens and additional functions. Many of these functions can also be accessed from the toolbar, status sidebar, or directly on the display using the mouse.

    File

    Allows spectral data files to be saved to and recalled from computer disk. Allows comparing a spectrum on disk with a spectrum in buffer memory. Allows saving and recalling instrument settings. Select a spectrum area to print. Create a description of the acquisition conditions and allROIA report of the contents for printing or archiving on disk. includingASCIIThe ability to export or import data in a format.

    Collect

    Provides menu options for Start, Stop, and Clear controls, real-time adjustment of thresholds, andMCSor buffer memory selection. Provide forSCAScan mode and display panel access via control, input control and ramp control.

    Calculate

    Includes automatic peak search and provides calculation of peak centroid, gross area, and net area within boundaries selected by markers. Provides operations for summing, smoothing, stripping, and normalizing spectra. Achieve linear, quadratic, or cubic calibration of horizontal scales to user-defined units via least squares fitting. Allows flat background subtraction to extract small peaks from high background.

    service

    Provides menu access to user-defined job programs, libraries for peak identification, and sample descriptions.

    ROI

    Provides recall, save, mark and unmark areas of interest (ROI) menu access.

    show

    Provides menu options for all functions listed under View. YesROIarea and/Or color the entire spectrum. Provides color selection for various functions in the screen. Select between uncalibrated and calibrated marker readings. Shows or hides gridlines in the expanded screen.
















    input

    All inputs except fast analog inputs are25needleDtype connector is provided.MCS-PCI-OPT2Options provide connection toDThe convenience of type connectorBNCconnector.

    IN

    Fast analog inputs are available on the rear panelBNCThe connector accepts amplitudes up to ±5 Vof analog or digital pulses. Pulses are counted when they exceed the discriminator threshold. The computer selects to trigger on positive or negative slope. The threshold can be determined by computer at-1.6 Vto+3 VAdjust within the range, with a step length of1.5 mV(The pulse amplitude must>30 mV). Computer optional50Ω or1000Ω input impedance, DC coupled. At the discriminator threshold, the minimum input pulse width is3.5 ns. The count rate is150 MHz。

    SCA IN

    1 MHzWindow discriminator (single channel analyzer) acceptable0to+12 VLinear signals are counted.SCAThe input is DC coupled, and the input impedance is1000 Ω. The minimum input pulse width is500 ns. The upper and lower thresholds can be accessed via computer from0Arrive+10 V(4096step) to adjust independently. Signals that rise above the lower threshold but do not exceed the upper threshold are counted when they fall below the lower threshold.

    start input

    Detected at start input0Arrive+2.5 Vagain0After the falling edge of the conversion, it will acceptTTLThe signal starts scanning on the next clock edge. In internal dwell mode, the next clock edge starts from50 MHzInternal time base is obtained. For external dwell mode, the next clock edge is obtained from the external channel advance input. Start input edges are ignored during scanning or when disabled by the Start enable input. The input impedance is1000 Ω is grounded. The minimum pulse width is10 ns。

    stop input

    accept from0Arrive+2.5 VexternalTTLEnter to stop scanning when the current scan ends. The minimum pulse width is10 ns. The input impedance is5000 Ω is grounded.

    CHN ADV IN(Channel advance input)

    When the signal crosses the threshold with a positive slope (external dwell selected), an analog or digital pulse is accepted to advance the channel. The threshold can be determined by computer at-1.6to+3 VWithin the range of1.5 mVstep size (pulse amplitude must be>30 mV) to adjust. The minimum stay time is100 ns. The minimum pulse width is10 ns. The input impedance is1000 Ω is grounded.

    gate input

    acceptTTLEnter to preventINandSCA INSignals in the connector are counted. When gate input<0.8 V, counting will be disabled. When the gate input level>2 VOr counting is enabled when the gate input is not connected to a signal source. The input impedance is1000 Ωto+5 V。

    TTL(Start enabling input)

    acceptTTLEnter to enable/Disables response to start input trigger. When booting enable input<0.8 V, triggering will be disabled. When starting enable input level>2 VOr triggering is enabled when the enable input is not connected to a source. The input impedance is5000 Ωto+5 V. The Start Enable input must be at the required level when the rising edge of the Start input arrives.
























    Output

    All outputs are in25needleDtype connector is provided.MCS-PCI-OPT2Options provide connection toDThe convenience of type connectorBNCconnector.

    start output

    When scanning starts, thisTTLOutput from<+0.4 Vrise to>+2.4 V, and then in160 nsreturn after<+0.4 V. Used to synchronize external instruments at the beginning of a scan. The output terminal has short circuit protection function and can drive ≥50 Ω impedance.

    CHN ADV OUT(Channel advance output)

    WhenEASY-MCSWhen advancing from one channel to the next, theTTLOutput from<+0.4 Vrise to>+2.4 V. The pulse width is approximately20 ns. The output terminal has short circuit protection function and can drive ≥50 Ω impedance.

    SCA OUT

    eachSCAinput signalTTLOutput pulses that occur between the upper and lower discriminator thresholds. WhenSCAThe input signal passes the discriminator threshold, and the output goes from<+0.4 Vrise to>+2.4 V. The nominal pulse width is250 ns. The output terminal has short circuit protection function and can drive ≥50 Ω impedance.

    Zhongtong output

    After scanning half of the channels in a pass, thisTTLOutput from<+0.4 Vrise to>+2.4 V. It returns at the end of passing<+0.4 V. The mid-pass output remains low if there is an odd number of channels in the pass, and high if there is one more channel. The output terminal has short circuit protection function and can drive ≥50 Ω impedance.

    Ramp output

    Provides an analog voltage ramp from a digital-to-analog converter to drive external devices. See the Ramp Control section for detailed instructions. The output voltage range can be determined by computer at0to+10 VAdjust within the range, the resolution is16Bit. For any range, the minimum voltage step size is approximately0.15 mV. The establishment time is2 μs. The output impedance is100 Ω, protected against short circuit.

















    electrical and mechanical

    Power requirements

    EASY-MCSPowered by the included power supply.

    voltage, current, power

    +12 V、250 mA、2.5 W。

    operating environment

    Temperature:0to50°C。Humidity:0Arrive80%, no condensation.

    Size

    Width:134 mm (5.25inches)
    Depth:205 mm (8.1inches). include28.6 mm (1.13inches) ofBNCconnector.
    Height:34.9 mm (1.38inches)

    weight

    Net weight 0.6Kilogram (1.3pounds).Shipping weight 2.3Kilogram (5pounds).












    Optional and related equipment

    MCS-PCI-OPT2

    cable.This cable canEASY-MCSon25needleDtype connector converts each input and output signal to a separateBNCCable connector. This option is highly recommended.

    A11-BW

    bringActiveX™ controlCONNECTIONSProgram development kitYou can write your own special software toLabVIEW®、Visual C++orVisual BasiccontrolEASY-MCS。








  • Ordering information +


    Model

    Description

    EASY-MCS

    EASY-MCSIncludes software and documentation