Detailed introduction

ORTEC 996 CCNIM Timer and Counter
  • 100 MHz, 8-bit decade counter and blind timer
  • Field-installable output options to meet a variety of measurement needs
  • Can be used as a non-printing counter and timer
  • RS-232-C plug-in option provides CCNIM™ functionality for computer control and data reading
  • Can directly drive printers with RS-232-C ports

The ORTEC Model 996 Timer and Counter contains a 100 MHz, 8-bit decade counter and a blind preset timer. The basic model displays readings via an 8-digit LED display. Readout and control capabilities can be expanded at any time by plugging in field-installable options.
  • information +

    • Download link 996 brochure
    • Download link 996 Brochure (A4)
    • Download link 996 manual
  • More information +


    The full functionality of CCNIM (Computer Controlled NIM) can be obtained by adding the RS-232-C option. This plug-in board allows computer control of all functions normally selectable from the front panel, including starting and stopping counting, reading, resetting, setting presets, displaying presets, displaying counter contents, and selecting the desired time base. To eliminate unintended operational interference, the computer can be in remote mode with all front panel controls disabled. With the CCNIM option, the computer can read the counter contents, preset values ​​and current display mode. The CCNIM option can directly drive printers with RS-232-C ports.

    The MN X 10P option provides maximum flexibility in setting presets. The M and N values ​​provide two-digit precision, while P has the option of decimal. Preset values ​​can be selected from 0.01 to 990,000 seconds, 0.01 to 990,000 minutes, or 1 to 99,000,000 counts. In external (EXT) time base mode, 996 becomes the displayed preset counter. The 996 can be used as a preset timer for the display by changing the position of the circuit board jumpers and using the 0.01-SEC or 0.01-MIN time base.

    The front panel provides the counter's positive and negative sensing inputs. The negative input is designed to accept NIM-standard fast negative logic pulses with a fixed threshold of -250 mV over a 50Ω input impedance. The negative input can handle count rates up to 100 MHz. The positive input can accept count rates up to 25 MHz on a 1000 Ω input impedance. To increase the flexibility of the positive input, a precision discriminator is integrated. The discriminator threshold can be adjusted from +100 mV to +9.5 V using the front-panel, 25-turn trimpot. The threshold can be adjusted to suit the amplitude of a specific logic pulse source or used as a precision integrating discriminator on analog pulses. For the latter application, the discriminator's TTL logic output serves as a front-panel test point. This output can be used to trigger the oscilloscope when viewing an analog signal at the oscilloscope's counter input. The oscilloscope trace will show the signal counted by the 996, allowing the threshold to be adjusted accordingly.

    All frequently used functions are conveniently accessible via the front panel. Count, stop and reset functions can be manually controlled via three buttons. When counting is enabled on the 996 model, the door LED will illuminate. Use the time base button to select 0.01 second, 0.01 minute or external time base. In external mode, a preset counter counts events at the positive or negative front panel input.

    The DISPLAY button switches the display to show the contents of the counter or a preset stop value. To change a preset, you must first select a preset mode using the DISPLAY button. The Preset Select button can then be used to select M, N or P for adjustments. Use the "Preset Advanced" button to change the value of M, N or P. There are LED indicators on the display to indicate whether M, N, or P has been selected, to warn when an overflow occurs in the counter, and to indicate when the computer in remote mode should disable front panel controls.

    When using the Model 996 without the plug-in option, a jumper on the circuit board selects automatic recirculation of counting intervals, with a display dwell time of 1 or 10 seconds at the end of each counting interval. The plug-in option disables the dwell/auto-recirculate function when enabled by an external controller.

    The counting function of the entire module can be disabled by holding the Gate input below +1.5 V using an external signal source. The door LED will then turn off. If counting mode is activated, an open circuit at the Gate input or greater than +3 V allows the instrument to start counting. The interval output of another ORTEC timer can perform this function to synchronize the Model 996's count with another timer. The interval outputs of all ORTEC timers provide nominal +5 V when counting and less than +0.5 V when counting is disabled.

    The interface connector for the plug-in RS-232-C option is located on the rear panel. The counter's overflow output is also located on the rear panel. Counting these overflows on another counter effectively extends the counting capacity of the Model 996.

    The Model 996 is powered by ±12 V and +6 V supplies from the standard NIM power box.

  • Specifications +


    Performance

    Counting capacity

    8bit decimal, the counting range is0Arrive99,999,999。

    Count rate

    Negative input is100 MHz, the positive input is25 MHz。

    time base

    10 MHzClock, minimum preset or display interval is0.01seconds or0.01minutes. The nominal value of synchronization error is100 ns. when choosingEXT(External) mode also accepts external input from the counter input.

    Time base accuracy

    in0to-50°Coperating temperature range, within ±0.0025Within %.

    Default time/count

    When the preset value is reached on the blind preset registerMN X 10P, the module will stop counting.MandNYes0Arrive9numbers between.PYes0Arrive6numbers between. Use0.01seconds time base, you can use0.01to990,000Preset time in seconds range. Use0.01Minute time base can be used0.01to990,000Preset time in minutes. inEXTIn time base mode, you can use1Arrive99,000,000Preset count within range.

    positive input discriminator

    25The circle trimmer potentiometer is available at+100 mVto+9.5 VAdjust the threshold within the range.

    Pulse pair resolution

    Negative input<10 ns;positive input<40 ns。


    indicator

    Counter display

    8Bit7segmentLEDDisplay with leading zero suppression function. When displaying time, include the2number of digits.

    Overflow indicator light

    When the counter exceeds its8digit decimal capacity, marked withOVFofLEDThe indicator light will light up. The indicator light remains on until reset.

    M、NandPindicator light

    threeLEDIndicators help select presets. WhenPRESET(Default) When the display function is activated,SEL(Select) button to choose which of these to light upLEDindicator light. when one ofLEDCan be used when litADV(Advanced) button to increment the preset value numerically.

    show

    Two are labeled count and presetLEDThe information shown in the counter display will be indicated. by repeatedly pressingDisplay(display) button until desiredLEDThe indicator light lights up to display the counter value or preset value.

    time base

    threeLEDThe selected time base source will be indicated. By pressing the time base button repeatedly, you can select0.01seconds,0.01minute or external mode

    door

    singleLEDUsed to indicate that counting is enabled for the entire instrument. to open the doorLEDilluminates, the module must be placed in counting mode (manually or via the interface option) and the "Gate" input must be above+3 VOr it is an open circuit, and the preset stopping conditions must not be reached.

    remote

    marked withREMof singleLEDused to indicate996The model is under computer control, with all front panel controls disabled. This mode consists ofENABLE_REMOTECommand settings.


    control

    show

    The button can be selected in8The digit decimal display shows the contents of the counter or the preset value. Press the button repeatedly to switch between count and presetLEDChoose between the two options indicated.

    SEL(select)

    Buttons display selections for preset valuesM、NorPNumbers. Press the button to light upLEDChoose between the three options indicated. Only when "Preset" mode is selected for the "Show" buttonSELButton is only valid.

    ADV(Advanced)

    Each time you pressADVbutton, the button will be added with aSELThe preset number selected by the button.MandNThe range of numbers is0Arrive9。PThe range of numbers is0Arrive6. Only when "Preset" mode is selected for the "Show" buttonADVButton is only valid.

    time base

    Press this button repeatedly to toggle between the three time base options (0.01seconds,0.01minutes andExt) to determine the time base source for the preset register.

    stop

    This button stops counting in all parts of the instrument.

    reset

    Pressing this button resets the counter to zero count and turns off the overflow indicator light. It also clears any counts accumulated in the blind preset register but does not change the selected preset value. When the module is powered on, it will be reset automatically.

    count

    Pressing this button enables counting conditions for the entire instrument, but only if the Gate input is not lower than+1.5 Vand has not reached the preset value.

    Thresh ADJ

    mounted on the front panel25A circle trimmer potentiometer that can be used to adjust the positive input threshold of the counter. The range is+100 mVto+9.5 V. Adjacent test points provide the discriminator outputTTLLogic signal for adjustment using an oscilloscope.

    Automatic recirculation and display dwell

    Usually,996The type will stop counting at the end of the counting interval and display the contents of the counter until theRESET(reset) button. You can use jumpers on the printed circuit boardW1Enable automatic recirculation counting mode. When automatic recirculation mode is selected, the display will pause at the end of the counting interval1or10seconds. At the end of the display dwell period, the model996reset, next count/Display dwell period begins. Use jumpers on the PCBW2, you can choose1or10Seconds show dwell time. When996When the model is under printing loop control or computer control, the display stays/Automatic recirculation mode will automatically be disabled.

    counter/timer jumper

    A two-position jumper located on the printed circuit board (W3) determines the information accumulated and displayed by the counter. WhenW3When in the counter position, the counter always counts and displays the value connected to the front panel input (POS IN、NEG IN) event. WhenW3When set to the timer position, if you select0.01seconds or0.01minute time base, the counter will count and display the time. If you chooseEXTtime base, the counter will count and display the input from the front panel (POS INorNEG In) event.

    1cycle/Recycle

    can passRS-232-Con the interface board8needleDIPswitch selection1Sub-circulation or recirculation mode. When996Recirculation mode can be used if the computer is able to respond with data transfer when the preset value is reached. After reaching the preset value,996The type latches its data into the buffer, resets the counter, and begins the next counting interval. This process takes approximately50 μs. The computer reads the data in the buffer before the end of the next counting interval. in1In secondary cycle mode,996The type simply stops counting when a preset value is reached and waits for further commands.


    Input

    POS IN
    (positive input)

    Front panel of counter inputBNCConnector accepts positive unipolar signal,Its minimum width is above the threshold,50%The duty cycle is20 ns. Thresholds are available via the front panel25circle trimmer potentiometer in+100 mVto+9.5 VAdjust within the range.Zin =1000 Ω to ground; DC coupled.

    NEG IN
    (Negative input)

    Counter front panelBNCConnector accepts-600to-1800 mVwithin rangeNIMStandard fast negative logic signal,The fixed discriminator threshold is-250 mV。Zin =50Ω; DC coupled. The minimum pulse width above threshold is4 ns。

    door

    front panelBNCInput connector acceptsNIMStandard slow logic pulses to control counting conditions across the module. If the instrument is in counting mode and the preset value has not been reached, then>+3 Vlevel or open circuit will allow counting. level<+1.5 VCounting will be disabled. The driving source must be able to absorb the5 mAof positive current. The inputs are protected to+25 V。


    Output

    interval

    front panel outputBNCThe connector provides a positive level during the count interval. When counting is enabled, the level is nominally+5 V;When counting is disabled, the level<+0.5 V。Zo~30 Ω。

    OVFL

    When the counter overflows its8When the capacity is decimal, the rear panel outputBNCConnector providedNIMStandard slow positive logic signal. The nominal amplitude of this signal is+5 V;The width is approx.20 μs。


    interface

    serial

    when insertingRS-232-Coption board, it will provide a rear panel25Pin GongDtype connector, included for standardRS-232-CAll signals for communication. It also contains for20 mAInterface for current loop communication. Field installableRS-232-COptions allow computer control of the following functions: count, stop, reset, remote, set presets, select display mode, and select desired time base. In remote mode, the computer can disable all front panel controls. Computer readable: count, preset value and display mode.


    electrical and mechanical

    Required power supply

    996Type and plug-in options are available from the ±12 Vand+6 Vpower supplyNIMGet power from the power box. The power required depends on the installed options shown in the power requirements table.

    +12 V

    -12 V

    +6 V

    Basic model996

    25 mA

    50 mA

    475 mA

    Model996addRS-232-COptions

    45 mA

    70 mA

    1000 mA

    weight

    Net weight 0.908Kilogram (2.0lbs) shipping weight 1.4Kilogram (3.1pounds)

    Size

    NIMStandard single width module,3.43 x 22.13cm (1.35 x 8.714inches) front panel, conforming toDOE/ER-0457Trequirements.


  • Ordering information +


    Model

    Description

    996

    Basic module without optional plugins.

    99X-1

    RS-232-CInterface options (cable not included)

    C-75

    mother to motherRS-232-CNull modem cable (3meters long).

    C-80

    male to femaleRS-232-Cextension cable (3meters long).