DigiDART-LF Portable Digital Multichannel Analyzer (MCA)
  • High performance and ruggedized 2k channels.
  • Complete packages including integrated probe available.
  • Digital Stability: Provides consistent results for long-term counting, changing count rates and changing temperatures.
  • No need to connect to PC to run.
  • Built-in backlit LCD display and control keypad - displays acquired data in real time.
  • Nuclide ID and activity calculation for nine regions of interest (ROI).
  • Fits in hand or on belt.
  • The memory can store >150 2k music scores.
  • Battery life > 9 hours.
  • Only 860g, battery not included.
  • information +

    • Download link DigiDART-LF brochure
    • Download link DigiDART-LF brochure (A4)
    • Download link DigiDart-LF Manual
  • More information +


    ORTEC digiDART-LF is a high performance multi-channel analyzer for use with NaI(Tl) radiation detectors and modern scintillators such as lanthanum halides. It is engineered for use in real-world portable gamma-ray spectroscopy measurement applications. The all-digital design adopted by digiDART-LF includes three ORTEC technologies.

    digiDART-LF... strong yet lightweight
    Weighing less than 860 grams, digiDART-LF is an attractive, lightweight instrument; easy to use and rugged. The outer shell is made of molded ABS - the same strong plastic widely used in cars. Like other tools, the exterior is coated with a shock-absorbing, non-slip, stain-resistant coating. The display and keyboard are recessed to protect them from damage if the instrument is dropped. The connectors are all on one side and are recessed for protection. The battery is inside - extra protected and covered by a splash-proof battery cover. Even when digiDART-LF is running, its battery can be charged in situ. The battery is truly integrated into the rugged digiDART-LF, rather than simply clipped onto the back panel; leaving it exposed and prone to breakage. Replacing the battery is easy: just open the battery cover to replace it.

    digiDART-LF display and keyboard
    Although digiDART-LF is computer controlled; it also comes with a built-in display and numeric keypad, a huge improvement over contemporary portable MCAs. The high-quality display and easy-to-use keyboard mean it can perform a variety of tasks without being connected to a computer.

    For field applications, a PC is difficult to carry and operate, but without a monitor, you won't be able to see the spectrum or results. digiDART-LF's built-in backlit LCD display panel and keypad provide you with the necessary data display and control. It has a clear spectrum display and enables start/stop control operations via simple keyboard input.

    digiDART-LF's spectral display is modeled after ORTEC's highly successful MAESTRO MCA emulator, which is used in thousands of systems. The 240 x 160 pixel LCD display enables users to monitor the acquisition process and instrument setup status without connecting to a PC. It has real-time spectrum display, peak information display and online activity calculation functions of the area of ​​interest. ROI is shown as a bar graph below the spectrum.

    Real-time activity calculation...no PC required!
    At the push of a button, DigiDART-LF performs nuclide ID and activity calculations based on internally stored calibration information without the need for a connected PC. Everything is user controllable: libraries used for analysis, peak labels displayed, unit labels and calibration parameters. They are all easily downloadable to digiDART-LF via MAESTRO and they can be changed in the field to suit your changing needs. Activities can be calculated for lists of up to 9 nuclides. Spectral data can be saved and then re-analyzed in more detail with more sophisticated computer analysis packages such as the A66SV-BW GammaVision Gamma Spectroscopy Measurement Software for scintillation radiation detectors.

    Operation menu
    All digiDART-LF screens and operations can be set up using the keypad and display. Operation is simple - press the number and Enter key to select what you want from the displayed list. The main contents include: view status, input ID, nuclide ROI content, peak information, select ROI, select status content, adjust controls, general settings and view memory content. The complete list of all features has been given in the specifications section.

    Using the keyboard and display, MCA settings can be verified or changed in the field without a host computer.

    protect
    Protecting your data is important, so the menus are password protected. Actions can be divided into two categories: users and administrators. The user password protects the instrument from unauthorized use. That is, you can protect the data stored in memory. ADMIN or Setup functions are protected by different administrator passwords. ADMIN functions can only be changed by administrators to ensure results are based on the correct parameters.

  • Specifications +


    show

    240 x 160Pixel backlightLCDProvides real-time spectrum display, status information and analysis results.

    Full screen display and zoom mode

    Show multipleROI。

    status line

    User configurable parameter display. You can choose from two options: cursor energy, position, live time, remaining live time, remaining real time, remaining power, count rate,ROICount rate, count.
    Spectrum display can be disabled from the connected computer using the Administrator function.

    energy calibration

    channel andFWHMTwo-point energy calibration.

    Online activity calculation

    Can be up to9Activity and uncertainty are calculated online for a user-defined area and displayed on the screen. Activity is obtained by dividing the net count rate by a user-supplied efficiency factor.

    Default

    Live time, real time, integrated peak count, peak count, uncertainty and multinuclidesMDA. Can specify up to20nuclideROI. when all are satisfiedMDACollection will stop when requested. real time/living time for1Multiples of seconds.

    keyboard

    20numbers and function keys. manyDigiDARTFunction keys are multi-function keys. The specific function depends on the state of the key when it is pressed. When the device passesUSBThe keyboard is locked when connected to the computer.














    Menu function

    Pressing the Menu button while the spectrum is displayed displays the main menu.

    View status

    Show all majorMCASettings, including: live time, real time, dead time, battery voltage, bias voltage, fine gain, coarse gain, rise time, flat top, baseline recovery[BLR]settings.

    inputID

    Used to enter the numbers contained in the spectrumIDinput dialog box.

    nuclideROI

    View the nuclide report and the settings menu for the nuclide report. for all9aROIEnter the following: Activate/Disable, label (text), unit (text), starting channel, number of channels, area multiple, clear thisROI, displays these settings.

    status line

    Set the status line at the top of the spectrum display to display any two of the following parameters: cursor position (energy), cursor position (channel), live time, real time, remaining live time, remaining real time, remaining battery, count rate,ROICount rate, marker channel count.

    Peak information

    Displays the centroid of the area determined by the marker location,FWHM, net count and gross count. Access is denied when the spectrum display is locked.

    Adjust controls

    A dialog box showing the following content:

    • High voltage setting:Review and set the following:enableHV, set bias voltage, set shutdown mode, view currentHVvalue, viewSOH。
    • Amplifier settings:Review and set the following:Coarse gain, fine gain, rise time, flat top, pole and zero, baseline recovery, optimization, preamp type, input polarity.
    • Default settings:Review and set the following:Live time preset, real time preset,ROIPoints default,ROIPeak preset, uncertainty preset,MDADefault.
    • ADCSettings:Set conversion gain,LLD、ULDand gate.
    • Stable settings:Enable, view and set gain and zero stabilizers.

    General settings

    Change user password
    Change administrator password
    Enter password
    Lock spectrum display
    Auto compare: enable or disable
    Calibration: Enter or view calibration
    show
    Adjust the vertical scale to automatic,Logor normal
    Set mode toPHA
    View settings

    spectral memory

    Retrieve, list or erase stored spectra.

































    Multi-channel analyzer (
    MCA)

    System throughput

    >100,000 cps

    System gain settings

    •Coarse gain adjustment:1、2、4、8、16or32
    •Fine-tune the gain:0.45Arrive1

    preamplifier

    The input terminal can accept positive or negative pulses with a rise time of10to650 ns, the decay time is40 μsto ∞;Zin>1000Ω DC coupling; linear value10 V;value20 V。

    System conversion gain

    from512Arrive2kSoftware control of channels.

    Digital filter shaping time constant

    •Rise time:0.8 μsto20 μs, the step size is0.2 μs。
    •Flat top:0.5to2.0, the step size is0.1 μs。

    Dead time correction

    According toGedcke-HaleMethod for extended live time correction.

    Linear

    •Integral nonlinearity:UseORTEC 448Pulse generator measurement, in front of the spectrum99.5%<±0.025%。
    •Differential nonlinearity:<±1%。
    •Digital Spectrum Stabilizer: Stabilizes gain and gain through computer control.

    temperature coefficient

    •Gain:<35 ppm/°C。[Usually30 ppm/°C。]
    •Offset:<3 ppm/°C, the rise and fall times are12 μs, the flat top is1 μs. (similar to simulation6 μsplastic surgery. )

    Pulse accumulation rejector

    Automatically set thresholds. Pulse pair resolution is typically500 ns。

    Automatic digital zero adjustment

    Computer controlled (U.S.5,872,363). Can be set automatically or manually.

    Digital gated baseline restorer

    Computer controlled recovery rate adjustment (high, low and automatic)

    LLD

    Set a digital low level discriminator on the channel.LLDSets the following hard truncation of data in the channel.

    ULD

    Set a digital high level discriminator on the channel.ULDSet up hard truncation of data in the channel above.

    counting rate meter

    MCAand/orPCThe count rate is displayed on the screen.

    battery

    The individual cells are inserted into the housing through the battery cover. The battery compartment is semi-sealed and dust-proof and moisture-proof. The battery can be replaced without losing data or recharged on site without tools.
    •Battery life:Use a fully charged SonyNP-F960and standardsORTECResistive feedback preamplifier up to12hours.
    •Battery type:Lithium-ion camera batteries. sonyNP-F960(7.2 V 38.8 Whours).































    input and output

    detector

    Multi-pin connector with the following functions:
    •Preamp power:1 W(+12 V,-12 V,+24 V,-24 V,2 GND)
    •Amp In:Normal amplifier input.
    •TRPsignal
    •Battery power:(5-12 V), used forHVmodule.

    USB

    used forPCUniversal Serial Bus for communication.

    power supply

    DC power supply. (+12 V DC <1.25 A)(digiDART-LFInternal charging circuit and battery management circuit).











    electrical and mechanical

    Size

    8inches x 5inches x 3inches (20.32 x 12.7 x 7.62 cm)

    weight

    <900grams (1.9pounds), batteries not included

    Operating temperature range

    -10to60°C, includingLCDdisplay.

    Radiation detector high voltage power supply

    DIM-POSNAI

    For use with preamplifiers that already havePMTpedestalNaIandLaBrdetector.
    •Preamp power: 9needleDfemale head,1 W(+12 V,12 V,+24 V,24 V,2 GND)。
    •Analog input:BNCMale head.
    •Bias output:SHV(HV) female head.0 +1800 V,600μA, lower than1000 V;300μA, higher than1000 V, positive polarity.
    •MCACoincidence gate input:BNCMale head. Includes leads with mating connectors for connecting to existing detector cables.

    DIM-296

    Applies to include10levelPMTdetectors, thesePMTNeed to have standards14Needle base.












  • Ordering information +


    Model

    Description

    DIGIDART-LF

    DigiDART-LF、2cable, battery and charger,MAESTRO MCASoftware, operating manual and instruction card. No detector interface module (DIM). if not withDIM-296orDIM-POSNAIused together, you needDIGIDART-OPT6。

    DD-LF-POSNAI

    DigiDART-LFbringDIM-POSNAIDetector interface module for positive biasNaIRadiation detector.

    DD-LF-296

    DigiDART-LFbringDIM-296Detector interface module forNaIorLaBrRadiation detector.

    DD-LF-2BY2

    DigiDART-LFwith rugged integrated2inches x 2inchesNaIradiation detector/DIM-296Components and carrying case.

    DD-LF-3BY3

    DigiDART-LFwith rugged integrated3inches x 3inchesNaIradiation detector/DIM-296Components and carrying case.

    DIGIDART-OPT1

    Backup high capacity battery

    DIGIDART-OPT2

    battery charger110-240 V 50/60 Hz

    DIGIDART-OPT2E

    battery charger110-240 V 50/60 Hz,CECertification applies to Europe

    DIGIDART-OPT3

    On-site kit:suspenders/Belt, automatic adapter, universal power adapter; spare battery

    DIGIDART-OPT6

    fan-out cable for use not includedDIMdetector. Provides analog sum gate inputs. (Requires conventional preamp output pulses.)

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7