EASY-MCA 2k or 8k channel multi-channel analyzer
Product model:
Brief description:Compact stand-alone MCA Two versions available with 2k or 8k resolution Fast (includes dead-time corrected logic inputs (BUSY and PUR) Gate signal input support With easy-to-use and feature-rich MAESTRO software Fast and convenient USB2 connectivity Advanced analysis software option EASY-MCA connects to PC via USB2 cable

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- How to use the American CIRS ATL040 ultrasound phantom for ultrasound equipment calibration?
- The core of the thermoluminescent dose box is the thermoluminescent detector
- Thermoluminescent dose tablets are a proven dose measurement tool
- Low contrast detail detection phantom丨Product Encyclopedia
- Quality control of imaging diagnosis and treatment: the application value of dose area product instrument
- When using the long pole radiation measuring instrument, the operating procedures must be strictly followed.
- Thermoluminescence dosimeter: an important tool for accurate radiation dose measurement
- Analysis of core parameters for purchasing radiation detectors: technical guide from sensitivity to anti-interference ability
- Online radiation alarm is the key equipment for modern radiation protection
- How to use and precautions for thermoluminescence personal dosimeter
Detailed introduction

- Compact freestanding MCA
- Two versions available, with resolutions of 2k or 8k
- Fast (<2 μs) conversion time
- Includes dead time correction logic inputs (BUSY and PUR)
- Gate signal input support
- MAESTRO software with ease of use and functionality*
- Fast and convenient USB2 connection
- Advanced analysis software options
information +
-
EASY-MCA brochure
-
EASY-MCA brochure (A4)
-
EASY-MCA Manual
-
More information +
EASY-MCA will accept input from the amplifier for pulse height analysis (PHA). In addition to input signals, EASY-MCA also accepts ADC gate signal input, stacking reject input (PUR) and busy signal input used by the live time correction circuit. A single computer, subject to USB-2.0 data transfer speeds, can control multiple devices using USB ports or powered USB hubs.Specifications +
Performance
ADC
ADCIncludes sliding scale linearization and<2 μsDead time (including memory transfers).
integral nonlinearity
before the dynamic range99Within %, ≤±0.025%。
differential nonlinearity
before the dynamic range99%,<±1%。
Gain stability
≤±50 ppm/°C。
Dead time correction
According toGedcke-HaleMethod for extended live time correction.
USBinterface
USB 2.0ArrivePCData transfer speeds up to480 Mbps。
input and outputInput
Accepts unipolar positive signals, positive gated integrators, or0to+10 VBipolar analog pulses that are predominantly positive within the dynamic range;+12 V;0.25Arrive30 μsThe semi-Gaussian time constant of3Arrive30 μsthe time constant of the gated integrator shape, or the delay line shape, where the width>0.25 μs。Zin =1kΩ, DC coupled. No internal delays,BNCconnector.
ADCdoor
OptionalTTLInput with computer-selectable coincidence mode, anti-match mode, or off. The signal must occur before and exceed the pulse peak0.5-μs;Zin =1kΩ。BNCconnector.
PUR
Stack rejection input; acceptTTLSignal; the signal must occur before peak detection.Zin= 1kΩ。BNCconnector.
busy
Busy signal input used by the live time correction circuit. acceptTTLSignal; the signal must occur before peak detection.Zin= 1kΩ。BNCconnector.
power supply
Right12 V, power capacity up to8 W。EASY-MCAComes with power supply and cable.
indicator lightADC
instructionsADCstatus
Software control
(With accompanyingMAESTROused together - For more information, seeMAESTRODatasheet. )ADC LLD
The computer can be accessed from0Arrive100% of full scale for control.
ADC ULD
The computer can be accessed from0Arrive100% of full scale for control.
Default
real time/living time
20Multiple of milliseconds.
area of interest
Peak count/Points counting.
Data overflow
When any channel exceeds231-1Data collection will be terminated.
peak uncertainty
Acquisition stops when the statistical or counting uncertainty of the user-selected net peak reaches a specified value.
nuclideMDA
When the user specifiesMCAMinimum detectable activity (MDA) value reaches the specified value, data collection will stop.
live time correction
Gedcke-Halemethod.
gate input
Conform, anti-conform, close.
electrical and mechanicalRequired power supply
Via the power cable and the DC power supply (mains voltage110-230 V/50-60 Hz) provided0.4Ampere+12 Vvoltage.
weight
Net weight:0.6Kilogram (1.3pounds)Shipping weight:2.3Kilogram (5pounds)
Size
34.9mm(1.38inches) high x 134mm(5.25inches) wide x 205mm(8.1inches) deep [include28.6mm(1.13inches)BNCconnector]
operating environment
0to50°C, relative humidity0to80%, no condensation.
Ordering information +
Model
Description
EASY-MCA-2K
compactstand-alone2kchannelMCA. includeMAESTRO、10feetUSBinterface cable,6ft. power cord and mains power.
EASY-MCA-8K
compactstand-alone8kchannelMCA. includeMAESTRO、10feetUSBinterface cable,6ft. power cord and mains power