KARRAY / PRODUCT DETAILS

9307 picosecond timing discriminator

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

9307 picosecond timing discriminator image

9307 picosecond timing discriminator

Product model:

Brief description:Suitable for microchannel plate detectors, microchannel plate photomultiplier tubes, channel multipliers, fast silicon photodiodes and fast photomultiplier tubes Accepts input pulses with widths from 400ps to 5ns and amplitudes from -50mV to -5V

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

ORTEC 9307 Pico Timing Discriminator
  • Suitable for microchannel plate detectors, microchannel plate photomultiplier tubes, channel multipliers, fast silicon photodiodes and fast photomultiplier tubes
  • Accepts input pulses with widths from 400 ps to 5 ns and amplitudes from -50 mV to -5 V.
  • From -150 mV to -1.5 V, time shift <±20 ps
  • Optimized internal pulse shaping without cable adjustments
  • One TTL output and two fast negative NIM timing outputs
  • Threshold adjustable from -25 mV to -1 V

The ORTEC Model 9307 Picosecond Timing Discriminator defines simulated pulse arrival times for ultra-fast detectors with picosecond accuracy. Furthermore, this performance is achieved over an extremely wide range of pulse heights, where pulse amplitude has negligible impact on the timing output. No adjustments to the pulse shaping cable are required when using the 9307 model. Internal pulse shaping in the picosecond timing discriminator can be used with microchannel plate detectors, microchannel plate photomultiplier tubes (PMTs), channel multipliers, fast photomultiplier tubes and fast silicon photodiodes to perform single photon or single ion time measurements.
  • information +

    • Download link 9307 Brochure
    • Download link 9307 Brochure (A4)
    • Download link 9307 Manual
  • More information +


    The picosecond timing discriminator accepts analog input pulses with amplitudes ranging from -50 mV to -5 V and pulse widths ranging from 400 ps to 5 ns FWHM. The 10-turn locking dial adjusts the amplitude threshold used to generate the timing output from -25 mV to -1 V.

    Ultra-fast circuitry integrated into the picosecond timing discriminator minimizes time shifts. Therefore, the input amplitude can vary in the range of 100:1 with negligible offset in the timing output. This ensures excellent time resolution even if the signal source produces a wide range of randomly varying signal amplitudes. Front-panel screwdriver adjustment controls allow fine-tuning of shift compensation to match specific detector characteristics. The adjustment process can be easily monitored using a voltmeter via adjacent test points.

    Two fast negative NIM outputs provide the flexibility to trigger time-amplitude converters (TACs) while driving other instruments. The 500 ns wide TTL output can be used in instruments requiring positive logic signals, such as counters and rate meters. The front panel LED flashes with each output pulse to indicate triggering.

    For detectors with rise times less than 1 ns, the ORTEC Model 9306 1 GHz preamplifier is used to amplify the small signal before it reaches the input of the Model 9307 Picosecond Timing Discriminator. For rise times ≥1 ns, the Model VT120 fast timing preamplifier should be used in place of the Model 9306. Model 9307 integrates a compatible 9-pin D-type connector on its rear panel to power the preamplifier.

  • Related equipment +


    The Model 9306 1 GHz Preamplifier is recommended for amplifying ultra-fast analog signals before they reach the input of the Model 9307 Pico Timing Discriminator. These ultra-fast analog signals require the use of 50Ω coaxial cable with SMA connectors. To maintain the 350 ps rise time of the Model 9306, the total cable length from the detector to the preamplifier, plus the preamplifier to the 9307, should be less than 1.7 m. Please see ordering information for appropriate SMA cables and adapters.

    For detectors with rise times >1 ns, type VT120 fast timing preamplifier should be used instead of type 9306. In this case, 50Ω coaxial cable with BNC connectors can be used. See the list below for information on BNC to SMA adapters and the "Cables and Accessories" data sheet for information on required cables.

  • Specifications +


    Performance

    Time transfer (swimming)

    for-150 mVArrive-1.5 Vinput signal amplitude, timing output offset<±20 ps. (for-50 mVArrive-5 Vsignal amplitude, usually<± 50 ps. ) using350 psrise and fall times1 nsWide input pulse measurement.

    Pulse pair resolution

    in rapid negativeNIMoutput terminal,<10 ns。

    input/Output rate

    Accept Gundam100 MHzburst rate.

    Operating temperature range

    0to50°C。

    threshold temperature sensitivity

    <±0.1 mV/°C(0to50°C)。

    Transmission Delay Temperature Sensitivity

    <±10 ps/°C(0to50°C)。


    Controls and lights

    threshold

    Front panel with locking dial10The loop potentiometer is available in-25 mVto-1 VAdjust the input discriminator threshold within the range.

    transfer compensation

    front panel20Turn screwdriver trim control for minimizing time shift as a function of input pulse amplitude. Available at approximately ±30 mVadjusted within the range. Front panel test points located next to the potentiometers help monitor actual settings. Test point output impedance:100 Ω。

    outputLED

    front panelLEDFlashes with each output pulse to indicate valid triggering.

    Input

    Input

    front panelSMAThe acceptable amplitude range of the connector is-50 mVto-5 Vunipolar input signal. Minimum input pulse width:400 ps(FWHM). Input pulse width:5 ns(FWHM). Input impedance:50 Ω. The inputs are protected to ±5 V。


    Output

    Quick negativeNIMOutput

    front panelBNCThe connector provides two independent fast negativeNIMOutput logic pulses. The nominal value of the output amplitude is-800 mVArrive50Ω load. The nominal pulse width is2.5 ns。

    TTLOutput

    front panelBNCThe connector is provided by a quick negativeNIMThe output triggers the positiveTTLpulse.TTLpulsed500 nsThe width is not updated. Output impedance:<1Ω, protected against short circuit.

    Preamp power supply

    rear panel9needleDType connector isORTEC 9306type1 GHzpreamplifier,VT120fast-timing preamplifier or other preamplifier with an industry-standard preamplifier power plug provides ±12 Vand±24 Vpower supply.


    electrical and mechanical

    Required power supply

    9307Type fromNIMPower box/power supply (e.g.ORTEC 4001A/4002Dtype) to obtain power. The required DC voltage and current are:+12 V, 35 mA; +6 V, 70 mA; -6 V, 360 mAand-12 V, 100 mA。

    weight

    Net weight0.9Kilogram (2.0pounds).Shipping weight 1.8Kilogram (4.0pounds).

    Size

    NIMStandard single width module,3.43 x 22.13cm (1.35 x 8.714inches) front panel, conforming toDOE/ER-0457Trequirements.




  • Ordering information +


    Model

    Description

    9307

    Picosecond timing discriminator

    SMA58-0.15

    RG-58A/U(50Ω) coaxial cable withSMAconnector, long0.15meters

    SMA58-0.5

    RG-58A/U(50Ω) coaxial cable withSMAconnector, long0.5meters

    SMA58-1.5

    RG-58A/U(50Ω) coaxial cable withSMAconnector, long1.5meters

    SMA/BNC

    SMAturnBNCAdapter with male connectorSMAand female headBNC

    BNC/SMA

    BNCturnSMAAdapter with male connectorBNVand female headSMA

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7