KARRAY / PRODUCT DETAILS

DSA simulated arterial blood vessel detection phantom KR201

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

DSA simulated arterial blood vessel detection phantom KR201 image

DSA simulated arterial blood vessel detection phantom KR201

Product model:

Brief description:1. Minimum resolution size of simulated arterial blood vessels and motion artifact detection module sculpting agent concentration: one piece each of 150mg/mL and 1300mg/mL, three simulated blood vessels, with width and thickness of 1.0, 2.0 and 4.0mm respectively. Each tube has simulated arterial stenosis and aneurysm. The widths are 1/4, 1/2 and 3/4 of the width of a single artery respectively. The module size is 300*150*25.4mm, as shown in the figure 2. Low-contrast iodine line pair test plug-in

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

1, Minimum resolution size of simulated arteries and motion artifact detection module

Shaping agent concentration:150mg/mL1300mg/mLOne piece each, three simulated blood vessels, the width and thickness are respectively1.0、2.0and4.0mm, with simulated arterial stenosis and aneurysm on each tube,

The width is the width of a single artery1/4、1/2and3/4, the module size is300*150*25.4mm, as shown in the figure2, low contrast iodine line pair test plug-in

There are3A group of test lines filled with iodine contrast agent, each group of lines consists of4It consists of lines with different diameters, and the diameters are respectively0.5、1.0、2.0 4.0mm。3The concentrations of iodine contrast agent in the group line groups are respectively2.5、5.0and10.0mg/cc. The module size is200*150*25.4mm, as shown in the figure

3, Image linear test plug-in

There are six circularly distributed on the test board19mmThe test area has different iodine thickness and triiodine concentration, respectively20.0、10.0、4.0、1.0、0.5mg/cm3, the size is200*150*25.4mm, as shown in the figure.4, skeleton simulation test block

Contains three simulated bonesPTFEBar, width is:25mm, the thicknesses are respectively5、10、15mmThick. Dimensions are200*200*25.4mm, as shown in the figure.5, blank insert

Plexiglas modules of uniform material with dimensions200*150*25.4mm, as shown in the figure6, stepped wedge test block

6ladder blocks (each25,4mmhigh) form a module. above3one and next3a“fold", it can become a200*200*76.5mm size module. As shown in the picture7, high contrast resolution test plug-in

Used with line-to-card, a groove for placing the line-to-card is opened on the test board, which can support line-to-card horizontal, vertical and45Virtual rotation positioning, line-to-card size:50*50mm. The module size is200*150*25.4mm。8, slot block (mold base)

The phantom has an opening that can be used to fix and position other modules to place different modules to achieve different parameter measurements. Module outer dimensions:200*200*76.5mm, slot size:200*150*25.4mm

9、Matching board Made of aluminum, covered3.2mmsize holes, dimensions:200*200*1.5mm

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.