Detective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

Detective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument. image

Detective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.

Product model:

Brief description:ORTEC's new Detective series product DX1 allows you to experience the future of radionuclide identification. As a new generation of high-purity germanium radionuclide identification instrument, the device sets new standards in terms of performance, ergonomic mechanics and network security.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

DX1

ORTECbrand newDetectiveSeriesProductsDX1canLet you experience the future of radionuclide identification——makeAs a new generation of high-purity germanium radionuclide identification instrument, the device sets new standards in terms of performance, ergonomic mechanics and network security.DX1toTraditional, proven, trustedDetective-XA foundation that combines reliability with enhanced functionality to meet the ever-changing needs of today's field professionals.

Measure and identify performance

  • Further improve detector energy resolution
  • Superpassed175comprehensive radionuclidelibrary, containing new radionuclide drugs
  • inAccuracy in identifying nuclear threat areas

useImproved user experience

  • 5inchesCapacitive touch screen greatly improves brightness and screen response sensitivity
  • inspired byRadEAGLET-RofModern, simple and intuitive user interface
  • Improved ergonomics and better counterweights

technologytechnology improvement

  • Built-inWLAN(802.11 b/g/n),Bluetooth5.1and10/100/1000MEthernet
  • supportGPSandGalileonavigation system
  • Modern network security features including secure boot, built-in firewall and deep static code vulnerability analysis
  • ultra high vacuumstructure, allowDX1ExploringRisk-free switching on and off at any stage of the detector's refrigeration cycle
  • information +


    Detective DX1 declarebrochure

    DX1 User Manual

  • nuclide library +


    Detective DX1 Configured with a very comprehensive range of nuclideslibrary. A subset of the nuclide library is the default“powerisotope”, and usered mark. Users with advanced permissions can tag other green non-threatening isotopes to this red threat list. The colors in the table below correspond to the device background screen color and visual alert when a nuclide is detected.

    2235 keV Peak Present
    Am-241
    Am-241 (shielded)
    Am-241 (unshielded)
    Neutrons
    Cf-252/Cf-249
    Enriched Uranium
    Geiger Muller CR
    HEU
    Neutrons
    Neutrons on Al
    Neutrons on Boron
    Neutrons on Fe
    Neutrons on Hydrogen
    Neutrons on Pb
    Neutrons or H.E. Gammas
    Np-237
    Pu-238
    Pu-239
    Radiation Detected
    U-232
    U-233

    U-235
    U-238
    Unknown Peak
    Unknown/Beta Emitter
    1001 keV Peak Present
    186 keV Peak Present
    2614 keV Peak Present
    356 keV Peak Present
    375/414 keV Peak Present
    662/722 keV Peak Present
    Ac-225
    Ac-227
    Ag-110m
    Ar-41
    As-72
    As-74
    At-211
    Au-198
    Ba-133
    Ba-140
    Be-7
    Beta Emitter
    Bi-207
    Bi-212 (Th232/U232 daughter)
    Bi-214 (Ra226 daughter)
    Br-76
    Br-76 (shielded)
    Br-76 (heavily shielded)
    Br-77
    Ca-47
    Cd-109
    Cd-115

    Ce-139
    Ce-141
    Ce-144
    Cm-242
    Cm-243
    Cm-244
    Co-56
    Co-56 (shielded)

    Co-55
    Co-57
    Co-57 (shielded)
    Co-58

    Co-60
    Cr-51
    Cs-131
    Cs-134
    Cs-137
    Cu-64
    Cu-67/Ga-67
    Eu-152
    Eu-154
    Eu-155
    Eu-156
    Fe-18
    Fe-59

    Ga-64
    Ga-64 (shielded)

    Ga-67
    Ga-67 (shielded)
    Ge-68/Ga-68
    Gd-153
    Gd-159
    Hf-181
    Hg-203
    Ho-166m
    Ho-166m (shielded)
    Ho-166
    I-123
    I-123 (shielded)
    I-124
    I-125
    I-126
    I-126 (shielded)
    I-131
    I-131 (shielded)
    I-132
    I-133

    I-134
    I-135
    In-111
    Ir-192
    Ir-192 (shielded)
    Ir-194 (shielded)
    K-40
    Kr-87
    Kr-88
    Kr-88 (shielded)
    La-138
    La-140
    Lu-172
    Lu-176
    Lu-177
    Lu-177m
    Mn-52
    Mn-54
    Mn-56
    Mo-99
    Na-22
    Na-24

    Nb-92
    N
    b-94
    Nb-95
    Nb-96
    Nb-96 (shielded)
    Nd-147 
    Os-194/Ir-194
    Pa-231
    Pb-203
    Pd-103
    Po-210
    Pr-144
    Ra-223
    Ra-226
    Rb-83
    Rb-86
    Rh-105
    Ru-97
    Ru-103
    Ru-106/Rh-106
    Sb-124
    Sb-124 (shielded)
    Sb-125
    Sb-127
    Sc-46
    Se-75
    Sm-153
    Sm-153 (shielded)
    Sn-113
    Sr-82/Rb-82
    Sr-85
    Sr-85/Kr-85
    Sr-89
    Suspect Neutrons
    Ta-182
    Tc-96

    Tc-99m
    Te-132
    Tl-201
    Tl-200
    Tl-202
    Tl-204
    Th-229
    Th-230
    Th-232
    Tm-170
    Tm-171
    V-48
    W-187
    W-188/Re-188
    Xe-127
    Xe-131m
    Xe-133
    Xe-133m
    Xe-135
    Y-88
    Y-91
    Yb-169
    Zn-65
    Zn-62
    Zr-95 
  • Sleuth mode user interface +


    newSleuthinterface andDetective-XofThe corresponding interface has the same functions and is implemented through new operating systems and software platforms.UIMade changesEnter. familiarDetective-XUsers of the corresponding version will easily transition to the new oneDX1ofon the application interface.

    Slueth
    The use of patternsThe user interface is very simple and easy to use. It is designed for non-professional users who do not use the equipment frequently and only need to quickly identify nuclides in the field and transmit the data to the back-end laboratory.

    Sleuth
    Interface features:

    • Applicable to non-Simplified screens for professionals
    • Can be used at any timeThe function of pausing and restarting counting when
    • passUse prompts to guide users to find the item to be measured and locate the appropriate location for measurement.
    • FunctionSimple, user-friendly touchscreen button setup

    SleuthPatterns are very easy to learnIt is easy to learn and use, and is specially designed for users in international departments who do not use the equipment frequently.

    in operationWhen employees have multiple tasks and must quickly and accurately evaluate the items to be tested,SleuthCan reduce people to the maximum extentopportunities for staff to make mistakes.

    Because of its useUser interface operations are limited,SluethCan significantlySimplify operator training process。

    DX1 1
    DX1 2
    DX1 3
  • RAPid application +


    newRAPiDinterface andDetective-XofThe corresponding interface has the same functions and is implemented through new operating systems and software platforms.UIMade changesEnter. familiarDetective-XUsers of the corresponding version will easily transition to the new oneDX1ofOn the application interface。

    RAPiD (Radionuclide Assisted Identification Program) is designed to meet specific customer needs to simplify data collection while minimizing annoying alarm notifications.

    RAPiD features include:

    • Source mode screen provides count rate, status, dead time andGPSThe location is OKaccess view
    •  Detection mode screen provides easy-to-view count rate, dead time readings and GPS coordinates
    • Identification mode screen shows elapsed count time
    • After reaching the preset recognition time, continue data collection
    • Pause data collection
    • If desired, the mode can be exited at the end of the measurement without forcing saving of the results
    • Freely choose local time instead of binding Zulu or CMT time
    • Recall energy spectra stored in the instrument and view details

     Detective-X RAPiD Software Survey Mode Screen
    Detective-X RAPiD Software Monitor Mode Screen
    Detective-X RAPiD Software Interface ID Mode Screen 1
    Detective X RAPiD Software Interface ID Mode Screen 2
  • tick service +


    Certified dose rate calibration services.ORTECprovideNISTTraceable calibrationCertification, measured values are in±10%fanWithin the range, the dose rate range0.01 mR/hrto2000 mR/hr. Includes all departmentsThe total measurement uncertainty of the systematic error sources is less than±20%. provideCertified calibration certificate. Dose rate calibration guarantee period oneyear