KARRAY / PRODUCT DETAILS

Detective X ultra-high resolution HPGe radioisotope identification device

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

Detective X ultra-high resolution HPGe radioisotope identification device image

Detective X ultra-high resolution HPGe radioisotope identification device

Product model:

Brief description:How to improve the gold standard for nuclear threat detection and identification? ORTEC’s new DetectiveX high-purity germanium (HPGe) RIID does just that through a combination of improved identification methods, improved operation, better interconnect capabilities, and longer battery life

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

ORTEC Detective X Ultra High Resolution HPGe Radioisotope Identification Device
How to improve the “gold standard” for nuclear threat detection and identification? ORTEC’s new Detective

Detection and identification functions
  • Larger HPGe crystal, three times more efficient than Micro-Detective-HX.
  • Improved algorithm that increases detection probability.
  • A nuclide library of over 175 radionuclides including new radiopharmaceuticals.
  • Better long-distance detection and identification capabilities.
Operational improvements
  • Durable instrument designed for harsh environments (IP65 compliant).
  • Significant weight reduction (about half that of Detective-EX-100T).
  • Doubled battery life and hot-swappable support.
  • New Li6/ZnS Neutron Detector Module (NDM), 3He-free.
  • Larger display, easy to read in sunlight.
quality improvement
  • The new Stirling cooler has greater cooling capacity and longer averaging time.
  • Lighter and stronger with an extremely tough polycarbonate shell.
Enhanced connectivity options
  • The system includes built-in Ethernet connectivity (RJ45).
  • USB connection to computer is plug and play.
  • USB flash drive can store > 100,000 spectra.
  • Mobile phone interconnection and instrument control support iOS, Android and Windows platforms.
  • WiFi and Bluetooth are standard on the Detective X.

New! TRANS-SPEC The application provides Detective X used asRequired for standard spectrometer systems MCA Simulation function. (See Detective-X-TS Integrated lightspectrometer.)

New! RAPiD The interface is designed toAddress specific customer needs to streamline data collection while minimizing annoying alert notifications.

  • information +

    • Download link Detective X brochure
    • Download link Detective X Brochure (A4)
    • Download link
    • Download link
    • Download link Detective X Manual
  • More information +


    Detective X Features
    • Portable - lightweight, can be operated with "one hand", and has GPS positioning function. The Detective X is approximately 50% lighter than the industry-leading ORTEC Detective-EX-100T.
    • Extremely Rugged - Designed for Military Use. Withstands temperatures ranging from -20°C to +50°C. IP65 protection level (waterproof, dustproof) and anti-fall design.
    • Algorithm - Excellent detection and nuclide identification capabilities and lower false alarm rate compared to other systems. More than 175 radionuclides are stored in the library.
    • Autocalibration - Continuous real-time detector stabilization continuously calibrates the instrument.
    • Enhanced communication capabilities - Equipped with IEEE 802.11a/b/g/e/i/h/j standards and IEEE 802.11n wireless, wired Ethernet, USB, Bluetooth, and remote control via smartphone (Android, iOS and Windows PC). Remote control and monitoring can be easily accomplished from the central control room.
    • Optional Li6ZnS neutron detector (without 3He).
    • Large capacity mobile USB flash drive.
    • Easy to operate: bright, clear, sunlight-readable display touch screen and intuitive menus.
    • Dual batteries (hot-swappable) provide up to 10 hours of operating time.
    • Large HPGe crystal (65 mm x 50 mm).

    Detective X algorithm
    In addition to the inherent selectivity of the HPGe detector type, Detective X's ultimate performance in terms of identification fidelity also depends on software algorithms. ORTEC licensed the original Lawrence Livermore RadScout algorithm in 2003 and made numerous improvements to it over the years. For example, as part of the DHS/DNDO HPRDS program, ORTEC developed the Advanced HPRDS RIID (Micro-HPRDS) from 2008 to 2010. Advances in this algorithm have greatly enhanced nuclide identification capabilities and minimized false alarms. Over the past 10 years, ORTEC has participated in various testing events sponsored by DNDO, DoD/DTRA, IAEA, and the U.S. Department of Energy National Laboratories to continue to improve algorithms and upgrade radionuclide libraries. Detective X uses algorithms and a large 65 mm x 50 mm crystal, making it the most accurate RIID on the market. The probability of false positives and false negatives is further reduced. If decisions need to be made about potential threat sources, backup experts also need HPGe spectrum. It is widely considered the "gold standard".

    Detective X Hardware Overview
    ORTEC has over 12 years of experience in HPGe RIID. Input from users around the world has been incorporated into Detective X. Detective X is compact, lightweight and has rugged hardware. The 40% high-efficiency (65 mm x 50 mm) HPGe crystal in the "ultra-high vacuum" cryostat is cooled by an integrated low-power Stirling refrigerator. The new refrigerator equipped with Detective X can provide greater cooling capacity. The ultra-high vacuum cryostat does not contain traditional molecular sieves, allowing the instrument to be turned on or off at any time during the detector cooling or rewarming cycle without any risk. ORTEC is one manufacturer that offers this feature in its handheld HPGe RIID.

    A built-in digital MCA system and a dedicated data processor will be delivered with the product. Detective X features a bright VGA resolution display and touch-sensitive operation screen that is readable under direct sunlight. The operation of Detective X is very intuitive. Radionuclide gamma-ray spectra can be displayed and manipulated (e.g., vertical scale, zoom) similar to traditional multichannel analyzers. Gamma count rate, neutron flux and gamma dose rate are displayed continuously.

    Using Detective X: Overview

    • The high-resolution, sunlight-readable color touch screen is designed for operating the system and entering data such as passwords and alarm limits.
    • The three physical buttons on the device (Power, Navigate (N) and Select (S)) can also be used for inspection and spectrum collection operations.

    Audiovisual feedback:

    • Bluetooth headsets can be used for audio alarms. The handle provides a vibration alarm.
    • The top of the screen displays the current dose rate in mrem/hr (or μSv or μGy). The corresponding icon shows whether the instrument has GPS activated (green) or inactive (red). The icons also show the status of MFK, Bluetooth, LCX mode stabilizer (when disabled) and WiFi (connected or not connected).
    • When radiation is detected and recognized, the recognition results will be displayed in the real-time recognition area of the screen. This area lists the names of any radioactive isotopes currently detected.

    operating mode

    Detection mode operation
    Detection mode is used to locate and identify sources. In this mode, the instrument continuously "seeks" but does not store data. The Detection Mode screen will display the detector count rate and dose rate. It is also in search mode and monitoring mode.

    The "Detection Mode" screen displays a strip chart of "Signal Index" and "SNM Index" in the middle of the screen. The strip chart updates every half second. They are real-time indicators of the presence of radioactive material. The strip chart sometimes shows an increasing trend before the recognition results are displayed on the screen.

    Inspection always starts with a measurement in inspection mode. Detective X is set to start automatically in detection mode.

    Identify mode operations
    This mode identifies radionuclides by counting a target object or area from a fixed location over an extended period of time. Collect data for a preset time period or before collection is stopped.

    The identification mode can operate in "single" spectrum mode or "multispectral analysis" mode. The mode is selected by the administrator. Single spectrum mode will initiate spectrum collection and perform radionuclide identification as the spectrum is collected. In multispectral mode, background, known and unknown spectra are collected, automatically packaged and sent to the control center.

    The default time is real time. During this time, the radionuclide ID is displayed on the screen as the nuclide name. The operator can view the spectrum in real time or have the screen display the ten gamma ray energies in the spectrum during identification.

    Detective X and background radiation - no more NORM alerts
    Unless the standard material is significantly higher than the stored background, Detective X can identify and suppress NORM identification results from the background measurement saved on the instrument.

    Detective X and Digital Stabilization - Performance
    Although the digital germanium spectrometer is a highly stable instrument under changing temperatures, the Detective X can even be used in conditions. The automatic gain stabilizer system will "lock" on the natural background K-40 peaks (if present) to ensure that calibration is achieved even under harsh processing conditions. The stabilizer is very "smart". If the K-40 is not found in the spectrum, the gain stabilizer will be turned off. Additionally, users can choose to disable the spectrum stabilizer and proceed directly to ID measurements to minimize setup time in mission-critical scenarios.

  • nuclide library +


    Detective X has a very comprehensive list of nuclides. A subset of the entire nuclide library is the default "threat isotopes"; they are marked red. Advanced users are able to add any nuclide marked green to the list of red threat isotopes. The color coding in the table shows the default background screen colors and visual alerts that will be displayed when the instrument encounters these nuclides.

    2235 keVPeak exists
    AM-241
    Am-241
    (shield)
    Am-241
    (unblocked)
    neutron
    Cf-252/Cf-249
    Enriched uranium
    Geiger-MillerCR
    HEU
    neutron
    Al
    neutrons on
    neutrons on boron
    Fe
    neutrons on
    neutrons on hydrogen
    Pb
    neutrons on
    neutron or helium gamma
    NP-237
    Pu-238
    Pu-239
    Radiation detected
    U-232
    U-233
    U-235
    U-238
    unknown peak
    unknown/beta emitter
    1001 keVPeak exists
    186 keV
    Peak exists
    2614 keV
    Peak exists
    356 keV
    Peak exists
    375/414 keV
    Peak exists
    662/722 keV
    Peak exists
    Ac-225
    Ac-227
    Ag-110m
    Ar-41
    As-72
    As-74
    At-211
    Au-198
    Ba-133
    Ba-140
    Be-7
    beta emitter
    Bi-207
    Bi-212 (Th232/U232
    daughter body)
    Bi-214 (Ra226
    daughter body)
    Br-76
    Br-76 (
    shield)
    Br-76 (
    Tightly shielded)
    Br-77
    Ca-47
    Cd-109
    Cd-115

    Ce-139
    Ce-141
    Ce-144
    Cm-242
    Cm-243
    Cm-244
    Co-56
    Co-56 (
    shield)

    Co-55
    Co-57
    Co-57 (
    shield)
    Co-58
    Co-60
    Cr-51
    Cs-131
    Cs-134
    Cs-137
    Cu-64
    Cu-67/Ga-67
    Eu-152
    Eu-154
    Eu-155
    Eu-156
    Fe-18
    Fe-59

    Ga-64
    Ga-64 (
    shield)
    Ga-67
    Ga-67 (
    shield)
    Ge-68/Ga-68
    Gd-153
    Gd-159
    Hf-181
    Hg-203
    Ho-166m
    Ho-166m (
    shield)
    Ho-166
    I-123
    I-123 (
    shield)
    I-124
    I-125
    I-126
    I-126 (
    shield)
    I-131
    I-131 (
    shield)
    I-132
    I-133

    I-134
    I-135
    In-111
    Ir-192
    Ir-192 (
    shield)
    Ir-194 (
    shield)
    K-40
    Kr-87
    Kr-88
    Kr-88 (
    shield)
    La-138
    La-140
    Lu-172
    Lu-176
    Lu-177
    Lu-177m
    Mn-52
    Mn-54
    Mn-56
    Mo-99
    Na-22
    Na-24

    Nb-92
    Nb-94
    Nb-95
    Nb-96
    Nb-96 (
    shield)
    Nd-147
    Os-194/Ir-194
    Pa-231
    Pb-203
    Pd-103
    Po-210
    Pr-144
    Ra-223
    Ra-226
    Rb-83
    Rb-86
    Rh-105
    Ru-97
    Ru-103
    Ru-106/Rh-106
    Sb-124
    Sb-124 (
    shield)
    Sb-125
    Sb-127
    Sc-46
    Se-75
    Sm-153
    Sm-153 (
    shield)
    Sn-113
    Sr-82/Rb-82
    Sr-85
    Sr-85/Kr-85
    Sr-89
    suspicious neutron
    Ta-182
    Tc-96

    Tc-99m
    Te-132
    Tl-201
    Tl-200
    Tl-202
    Tl-204
    Th-229
    Th-230
    Th-232
    Tm-170
    Tm-171
    V-48
    W-187
    W-188/Re-188
    Xe-127
    Xe-131m
    Xe-133
    Xe-133m
    Xe-135
    Y-88
    Y-91
    Yb-169
    Zn-65
    Zn-62
    Zr-95

  • detection mode interface +


    The Detective Mode user interface is a simple and easy-to-use mode for Detective X. It is specially designed for customers who may not use the instrument frequently, need to perform nuclide screening measurements quickly, and need to report data to foreign countries.

    The detection mode in Detective X software integrates the following functions:
    • An extremely simple and easy-to-use user interface, even if you are not an expert in energy spectroscopy, you can easily get started.
    • You can start, pause, and restart a measurement at any time. This function can save accumulated data, and users can perform other operations.
    • Help users determine the measurement distance for the Item of Primary Concern.
    • A warning interface will remind the user to shut down the Stirling refrigerator before shipment.
    • More simplified touch screen buttons for ease of use.

    Detection mode is an extremely easy-to-use and simple-to-operate mode. It is especially suitable for personnel in some government departments who may not use such instruments every day like professional laboratory analysts. .

    Detection mode reduces the chance of errors. Especially when operators perform multiple tasks at the same time, they can quickly and accurately assess the threat level posed by the Item of Primary Concern.

    Due to the extremely simplified user interface, detection mode can greatly simplify the training of relevant operators.
    ORTEC Detective X Sleuth Mode - Distance to Source 
    ORTEC Detective X Sleuth Mode - Main Screen
    ORTEC Detective X Sleuth Mode - End Count
  • RAPiD interface +


    The RAPiD (Radiological Assistance Program iDentification) app is designed to meet specific customer needs, streamlining data collection while minimizing annoying alarm notifications. The RAPiD app offers an enhanced home screen layout inspired by the Detective-EX-100 interface, providing quick access to monitoring mode while improving pause and file save functionality.

    RAPiD features:
    • The Measurement Mode screen provides a more accessible view of count rate, status, dead time, and GPS position.
    • The monitor mode screen provides easy-to-view count rate, dead time readings, and GPS coordinates.
    • The ID mode screen shows the elapsed count time.
    • Data collection continues after the preset recognition time is reached.
    • Pause data collection.
    • Exit ID mode at the end of the measurement without saving the results. (The Detective-X application requires that all ID measurements be saved to exit the ID mode screen.)
    • Choose local time instead of GMT or CMT time.
    • Recall spectra stored in the instrument and view detailed information (including viewing the actual spectrum).
    • Dose rate units can also be displayed in mR/hr.
    • Dose calibration information can be displayed on the screen.

    To add RAPiD to your existing Detective-X, order model number DET-X-SW-UPG. Includes RAPiD user interface and improved dose rate algorithm. The Detective-X will undergo a comprehensive incoming inspection and functionality check, software and firmware versions installed, BIOS upgraded (if required), and the instrument will be dose rate calibrated at an A2LA accredited laboratory. Certified calibration certificate provided. Dose rate calibration is guaranteed for one year.
     Detective-X RAPiD Software Survey Mode Screen
    Detective-X RAPiD Software Monitor Mode Screen
    Detective-X RAPiD Software Interface ID Mode Screen 1
    Detective X RAPiD Software Interface ID Mode Screen 2
  • TRANS-SPEC Application +


    ORTEC Detective-X-TS - Trans-SPEC application on Detective-XThe TRANS-SPEC application providesThe instrument is necessary for use as a standard spectrometer systemBasic MCA emulation functionality.Includes the ability to change hardware settings, establish energy calibrations and acquire spectra.When using the TRANS-SPEC application, hardware settings need to be configured on the remote computer and retained.Field measurements can then be made using the same configuration established in software applications such as MAESTRO, GammaVision, Isotopic.These hardware settings are also independent of the isotope identification applications (DETECTIVE X, Sleuth and RAPiD), so different configurations can be established when using standard spectrometer mode and isotope identification mode.

    Application characteristics
    • Main spectrum display: Log/Lin, Zoom, ROI, Start, End, Clear to collect and save spectra.
    • Peak/ROI data: center, FWHM, start/end track address, gross and net area and count rate.
    • Configurable spectral tag data: energy, track address, count.
    • Configurable status bar: Any two of the following: live time, actual time, remaining live time, remaining actual time, remaining battery, count rate, count rate for ROI.
    • MCA control: ADC conversion gain with upper and lower level discriminator, coarse and fine amplification gain, baseline recovery (auto, fast, slow), gain and pole zero, high voltage switch.
    • Get presets: Live Time, Actual Time, ROI Peak and ROI Integral.     
    • Health: ±12 V, +3.3 V, Detector Temp, Cooler Temp, Cold Junction Temp, High Voltage.
    • Security: Password protected user/admin mode, Lock/hide spectrum display during acquisition.
    • Energy scale: Quadratic fit of energy vs. address.
    • Application Interface: Compatible with all ORTEC CONNECTIONS-based applications such as MAESTRO, MAESTRO-Pro, GammaVision, Isotopic, Renaissance and the wide-ranging A11 toolkit.
    ORTEC Detective-X-TS - Detective-X with Trans-SPEC Application
  • tick service +


    Certified Dose Rate Calibration Service

    ORTEC offers NIST-certified traceable graduation services performed by an independent third-party laboratory. Measurements were within ±10% for ten dose rates from 0.01 mR/hr to 2000 mR/hr. The total measurement error including all systematic errors is less than ±20%. Certified graduation certificate provided. Dose rate scale is guaranteed for one year.
     

    Ordering information: Order model number DET-X-DOSE-CALIB. Requires software v2.4.1 or higher. If your Detective-X does not have v2.4.1 or higher software, you must order the DET-X-SW-UPG (see RAPiD Interface Options).
  • Specifications +


    detector

    Nuclide identification

    Ptype high purity germanium (HPGe) crystal, coaxial structure. Crystal nominal size 65mm diameter ×50mm long.

    Cryostats and Refrigerators

    "Ultra-high vacuum" cryostats, and highly reliable, low-power Stirling refrigerators. The cryostat is designed so that the user can turn it off and on again at any timeDetective X, without having to wait for a complete rewarming cycle (rewarming before cooling). This feature significantly increases system availability during measurement activities.

    Cooling time

    High reliability chillers are designed for continuous operation. Between measurements, the instrument is powered by DC power, a car battery, or other device. The initial cooling time depends on the ambient temperature, but25°Cusually 6hours.

    gamma dose rate detector

    Three detectors can measure gamma dose rates ranging from 0.1 mR/h to 2000 mR/h. The instrument can automatically switch between high-purity germanium detector, low-range GM tube and high-range GM tube. The dose rate is guaranteed to be accurate±10%, excluding propagation of systematic errors,ExampleSuch as the accuracy of calibration standards. For customers using certified dose rate calibration equipment, the Dose Rate Wizard allows the system to perform dose rate calibration. For customers requiring dose rate calibration guaranteed by the manufacturer, ORTEC offers dose rate calibration services.

    Gamma energy range Detective X and Detective X-N = 40 keV to 3 MeV.
    Detective X-8 and Detective X-8-N = 40 keV to 8 MeV.

    Neutron Detector Module

    The optional neutron detector is bulk lithium fluoride-6/Zinc sulfide (Li6F/ZnS) detector, consistent withANSI N42.34 2015standard.

    Hardware

    numbersMCAand data processor

    Display:4.3inchesWQVGA(480 x 272pixels) are sunlight readable, touch sensitive, and can be operated with fingers or a stylus.

    Data processor:FREESCALE I.MX535, the working frequency is1 GHz。

    data storage

    Media: Store to internalRAMandUSBon the flash drive. The instrument is equipped with a16 GBFlash drive to store100,000Multiple spectra.

    File format:ANSI N42.42。

    computer interface

    USBand EthernetTCP/IP v4connection, via standardsRJ45Ethernet connection (10/100Base-T - 10/100Mbps, adaptive). Available at any time withMFK(DoDmobile field toolkit for users),ORTEC GammaVision、iOSequipment andAndroidequipment used in combination.Wi-Fi(IEEE 802.11a/b/g/e/i/h/jStandard andIEEE 802.11n) communication. wireless mobileMCBServer software.

    wireless connection

    IEEE 802.11a/b/g/e/i/h/jStandard andIEEE 802.11nWireless and Bluetooth. Supports all current protected access protocols, includingWPAandWPA2。

    GPS(Positioning system)

    The instrument has built-inGPS(positioning system). Location information associated with measurements is optionally stored inN42in the file.

    RF safety If Detective X needs to be used in an environment without RF signals for security reasons, the RF Secure option can disable WiFi, Bluetooth and GPS signals. If you need this function, add "DETECTIVE-X-OPT-RFSECURE" to the accessories list.

    numbersMCA, internal memory with multiple spectral data

    Digital noise suppression:“LFRfilter".

    Conversion gain:16kchannel.

    Number of stored spectra:No limits on mobile storage.

    Physical specifications

    Dimensions

    Dimensions for each model and configuration (including handle and germanium detector end cap):
    DETECTIVE-X and DETECTIVE-X-8 without straps L 15.5 in x W 5.6 in x H 8.3 in (L 39.5 cm x W 14.3 cm x H 21.0 cm)
    DETECTIVE-X and DETECTIVE-X-8 with shoulder strap L 15.5 in x W 6.4 in x H 8.3 in (L 39.5 cm x W 16.3 cm x H 21.0 cm)
    DETECTIVE-X-N and DETECTIVE-X-8-N with neutron detector (with or without shoulder strap) L 15.5 in x W 6.4 in x H 8.3 in (L 39.5 cm x W 16.3 cm x H 21 cm)

    weight

    15lb(γ).17lb(γ/neutrons).

    internal battery

    2Rechargeable lithium-ion battery. Nominal per block98 Wh. WhenHPGeWhen the detector is cold,25°CThe battery life under the8hours. Charging time<4hours. The internal battery is easily replaced.

    external battery

    Battery life can be extended indefinitely by using an optional external battery pack. External battery (model2590) weighs less than3.25pounds, battery life extended to> 16hours.

    Input power

    from batteries or DC power (including universal mains power)12to17 V DC。

    Power consumption

    During cooling and battery charging:<100Watts. The cold state of the battery when fully charged<35 W。

    Scope of work

    Temperature:-20°Cto50°C。

    Relative humidity:95%, no condensation.

    Instrument housing

    IP65Sealing prevents dust and water from entering. All jacks are sealed with rubber plugs (interfaces, memory cards, etc.)

    Communication software

    Detective X is a member of the ORTEC CONNECTIONS family. Remote MCA control, even over the network, is possible via the MAESTRO-PRO advanced spectrum software included in the configuration.

    Multiple spectra can be passedUSBConnections are grouped from the instrument controller to the externalPC. When connected to a laptop orPCwhen,Detective XDisplayed as a flash drive. The exported file usesN42format, can be used by most expert teams in programs such asCAMBIOandPeakEasy) andORTECsoftware products (such asGammaVision) read.

    Detective X
    Equipped withIEEE 802.11a/b/g/e/i/h/jStandard andIEEE 802.11nWireless and Bluetooth, can be used with mobile phones, laptops and remote computer systems.Detective XCan be easily used withMFKsoftware,ORTEC GammaVisionsoftware,iOSdevice (iPhone®、iPAD) andAndroid®equipment used in combination.

    Mobile MCB Server

    moveMCBServer software applications enableDetective Xable to work withORTECsoftware applications (such asMAESTRO、GammaVisionandDetective-Remote®) for wired or wireless communication.

    The user can use the optionalA11Toolkit to develop your own applications.

  • Learning Center +


    Germanium Advantages

  • Ordering information +


    Model

    Description

    DETECTIVE-X

    3 MeVEnhanced functionality, ultra-light, portable and efficientHPGerecognizer(γ). includeGPS, power adapter, car power cord,16 GBminiUSBFlash drive, shoulder strap, Sleuth interface, RAPiD interface, TRANS-SPEC interface, MAESTRO software, Bluetooth headset and wheeled hard case.

    DETECTIVE-X-N

    3 MeVEnhanced functionality, ultra-light, portable and efficientHPGeIdentifier (gamma and neutron). includeGPS, power adapter, car power cord,16 GBminiUSBFlash drive, shoulder strap, Sleuth interface, RAPiD interface, TRANS-SPEC interface, MAESTRO software, Bluetooth headsets and wheeled hard cases.

    DETECTIVE-X-8

    8 MeVEnhanced functionality, ultra-light, portable and efficientHPGerecognizer(γ). includeGPS, power adapter, car power cord,16 GBminiUSBFlash drive, shoulder strap, Sleuth interface, RAPiD interface, TRANS-SPEC interface, MAESTRO software, Bluetooth headsets and wheeled hard cases.

    DETECTIVE-X-8-N

    8 MeVEnhanced functionality, ultra-light, portable and efficientHPGeIdentifier (gamma and neutron). includeGPS, power adapter, car power cord,16 GBminiUSBFlash drive, shoulder strap, Sleuth interface, RAPiD interface, TRANS-SPEC interface, MAESTRO software, Bluetooth headsets and wheeled hard cases.

    DETECTIVE-X-ACC-BAT

    Lithium-ion battery.

    DETECTIVE-X-ACC-DUAL-CHGR

    Standalone dual battery charger and calibrator.

    DETECTIVE-X-ACC-VEHCHGR

    Car power adapter cable.

    DETECTIVE-X-ACC-PS

    Universal AC power supply.

    DETECTIVE-X-ACC-2590-CABLE

    for connection2590Battery cable for battery.

    DETECTIVE-X-ACC-RCFILTER

    Low energy gamma filter.

    DETECTIVE-X-ACC-COL-W

    tungsten collimator,4mm thick.

    DETECTIVE-X-ACC-COL-ST

    steel collimator,4mm thick.

    DETECTIVE-X-ACC-TRANSPORTCASE

    Wheeled transport box.

    DETECTIVE-X-ACC-BLUETOOTH-HS

    Bluetooth headset.

    DETECTIVE-X-ACC-USBFLASH

    16 GB USBMini flash drive.

    DETECTIVE-X-ACC-WIFI-ADAPTER WiFi 802.11 B/G/N USB adapter
    DETECTIVE-X-ACC-SHOULDER-STRAP
    Shoulder strap
    DETECTIVE-X-ACC-MANUAL
    Manual
    DETECTIVE-X-ACC-STYLUS
    stylus
    DETECTIVE-X-ACC-RETRACTABLE-CORD
    Telescopic cord for stylus

    DETECTIVE-X-NEUTRON-DETECTOR

    Li6/ZnSNeutron detector.

    DETECTIVE-X-OPT-RFSECURE
    Remove WiFi, Bluetooth and GPS from Detective X. 
    EXT-BAT-X

    Super battery expansion pack. used forDetective Xof batteries, chargers and cables.

    M-1-T2-X-VERT

    used forDetective-Xof variable length tripods and mounting hardware.

    M-1-T2

    used forDetectivemodel andtrans-SPECVariable length tripod model

    M-1-T2-BRKT-X-VERT

    inM-1-T2Used on tripodDetective-Xvertical mounting bracket

    DET-X-SW-UPG
    Contains Sleuth interface, RAPiD interface, TRANS-SPEC application and improved dose rate algorithm. The Detective-X will undergo a comprehensive hardware and functional review, the software and hardware will be installed, the BIOS will be upgraded (if required), and the device will be dose rate calibrated in a qualified laboratory (see DET-X-DOSE-CALIB description below). Calibration certificates are available. Dose rate scales are guaranteed for one year.
    DET-X-DOSE-CALIB
    Dose rate scale certification services. ORTEC offers NIST traceable scale certification that measures ten dose rates from .01 mR/hr to 2000 mR/hr to within ±10%. The total measurement error including all systematic error sources is less than ±20%. Scale certification certificate available. Dose rate scales are guaranteed for one year. Requires software v2.4.1 or later

    If Detective-X software is not v2.4.1 or newer, then DET-X-SW-UPG must be ordered.

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.