KARRAY / PRODUCT DETAILS

MPC-900-DP manual single sample counter

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

MPC-900-DP manual single sample counter image

MPC-900-DP manual single sample counter

Product model:

Brief description:Dual scintillator detector with touch screen control, lightweight and portable, 5.1cm (2in.) diameter, radon compensation function

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Detailed introduction

ORTEC MPC-900-DP Manual Single Sample Gross Alpha Beta Counter
  • Dual scintillator detector
  • Touch screen control
  • Light and portable
  • 5.1 cm (2 in.) diameter
  • Radon compensation function for air filters
  • Optional scintillator anti-coincidence detector
  • Optional lead shield to reduce background levels
  • Includes PIC Link cable and two 5/16 inch sample holders
  • information +

    • Download link Alpha/Beta Manual Counting System Brochure
    • Download link α/β Manual Counting System Brochure (A4)
  • More Information +


    The MPC-900-DP is a convenient, versatile "desktop" counter that uses dual scintillator detectors, requires no working gas, and is easy to carry. Optional anti-coincidence guard detectors reduce background levels. DUO Express software allows users to perform data management and quality analysis through easy programming. Multiple devices can be connected for user convenience. This type of counter is ideal for standard health physics applications such as wipe sample measurement, or air filter paper measurement.
  • Specifications +


    Optimized for low-energy Beta rays
    Typical efficiency
    source top 1/8" bottom 1/4" bottom 5/16" bottom
    Pu-239 41% 34% 27% 24%
    SrY-90 53% 46% 39% 37%
    Tc-99  34% 28% 24% 22%
    Background
    Conditions Guaranteed value (CPM) Typical value (CPM)
    Alpha Beta Alpha Beta
    Configuring lead shielding and compliance detectors <0.2 <25 0.05 20
    Configuration conforms to the detector, lead-free shielding <0.2 <30 0.06 27
    Configured with lead shielding, no coincidence detector <0.2 <55 0.09 43
    Lead shielding and compliance detector not configured <0.2 <65 0.08 49

    Optimized for high energy beta rays
    Typical efficiency
    source top 1/8" bottom 1/4" bottom 5/16" bottom
    Pu-239 40% 33% 27% 24%
    SrY-90 50% 43% 37% 35%
    Tc-99 27% 22% 19% 17%
     Background
    Conditions Guaranteed value (CPM) Typical value (CPM)
    Alpha Beta Alpha Beta
    Install lead shielding and compliance detectors <0.2 <25 0.05 15
    Configuration conforms to the detector, lead-free shielding <0.2 <30 0.05 19
    Configured with lead shielding, no coincidence detector <0.2 <55 0.05 34
    Lead shielding and compliance detector not configured <0.2 <65 0.05 39

    Physical parameters
    detector 2 in. (5.1 cm) diameter, ZnS + plastic scintillator
    Sample tray 2 in. (5.1 cm) diameter, 1/8, 1/4, 5/16 in. (3.2, 6.3, 7.9 mm) deep
    Number of measurement channels 1
    Depth 1/8, 1/4, or 5/16 inch
    Data export USB Flash Drive, USB PIC Link
    interface touch screen
    Counting mode Only Alpha is measured, Alpha/Beta are measured simultaneously, Alpha first and then Beta.
    power supply 110–240 V AC, 50–60 Hz Input
    window material Aluminum film, 80 µg/cm2
    working temperature 10°C to 40°C (50°F to 104°F)
    Size 20.25 x 9 x 16 in. (51.4 x 22.9 x 40.6 cm)
    weight 40 lb., optional compliance detector +7 lb., optional shield +50 lb.
  • Ordering information +


    Model Description
    ORT-MPC-900-DP Manual sample change single sample counter
    Optional accessories  
    PIC-700-0007 1/8 inch Planchet
    PIC-700-0008 1/4 inch Planchet
    PIC-700-0009 5/16 inch Planchet
    PIC-140-0278-1/8 2 inch x 1/8 inch Sample Carrier
    PIC-140-0278-1/4 2 inch x 1/4 inch Sample Carrier
    PIC-140-0278-5/16 2 inch x 5/16 inch Sample Carrier
    PIC-140-0045 1 inch retaining ring
    ORT-MPC-900-SHLD shielding ring
    PIC-120-0084 Fits detector assembly (adds ~2.5" height)

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7