
German QUART-biopsy phantom (mammography test phantom)
Product model:
Brief description:Product introduction of German QUART biopsy phantom: German QUART biopsy phantom is specially designed for QA/QC in stereotactic biopsy systems in digital and analog mammography. Its design is optimized for all common image formats and a field of view (FoV) of 4 x 4 cm. Phantom's integrated test objects enable comprehensive QA/QC testing.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- This knowledge of CT dose detection phantom is worth learning
- Solid water phantoms are available in a variety of standard sheet thicknesses
- Application scenarios for low-contrast detail detection phantoms
- What is the specific role of CT performance testing phantom?
- How to use the American CIRS ATL040 ultrasound phantom for ultrasound equipment calibration?
- Low contrast detail detection phantom丨Product Encyclopedia
- Application of low contrast detail detection phantom
- Precautions when using dental phantoms
- Low-contrast detection phantom to protect health
- Basic requirements for maintenance and upkeep of X-ray machine comprehensive tester
Detailed introduction
Overview
german quarterQUART biopsy phantom product introduction:
germanyThe QUART biopsy phantom is designed for QA/QC in stereotactic biopsy systems in digital and analog mammography.
It is designed to target all common image formats andOptimized for 4 x 4 cm field of view (FoV). Phantom's integrated test objects enable comprehensive QA/QC testing.
germanyThe QUART biopsy phantom allows examination of actual low-contrast properties. Low-contrast resolution can be verified against sensitivity limits, providing a solid basis for accurate device calibration. One exposure is sufficient to obtain all test parameters. Phantoms are needed to test equipment used in the national mammography screening program.
german quarterQUART Biopsy Phantom Technical Specifications:
Internal filtering:46 mm PMMA
Spatial resolution:6 Landolt objects in 1 group
Dynamic steps:4 steps
Contrast details: in steps4 object details
Visibility Threshold: Low Contrast Wedge with Predefined Constants
Uniformity:2 pixel value measurement fields
Geometric accuracy: spirit level; 10mm split
Dimensions:80 x 70 x 46 mm (LxWxD)
german quarterQUART biopsy phantom technical parameters:
visual spatial resolution
low contrast
Minimum contrast (sensitivity limit)
horizontal homogeneity
X-ray field collimation
Artifact/image defectdistance
Product consultation
- Previous article:German QUART whole body X-ray training phantom
- Next article:German QUART dental X-ray head phantom



Product consultation
Contact


