KARRAY / PRODUCT DETAILS

American CIRS 700QA CT imaging QA kit ATOM phantom

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

American CIRS 700QA CT imaging QA kit ATOM phantom image

American CIRS 700QA CT imaging QA kit ATOM phantom

Product model:

Brief description:CIRS CT imaging QA kit is suitable for CIRS ATOM dosimetry model and CIRS 007TE tissue equivalent CT dose model, and has been widely used in CT dosimetry. The insert included in the kit is designed to study the correlation between image quality and CT dose. The kit provides various targets for the assessment of two important CT performance parameters: low-contrast detectability and spatial resolution of soft tissue and lung regions.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Related articles

RELATED ARTICLES

Detailed introduction

USACIRS 700QA CT Imaging QA Kit ATOM Phantom

 

Introduction:

CIRS 700QA CT Imaging QA Kit ATOM Phantom

CT quality control uses anthropomorphic phantoms

traditionalCT scanner dosimetry uses standard CTDI models, such as CIRS Model 007 CT Dose Phantom. However, more complex CT protocols and continued equipment improvements require the use of anthropomorphic phantoms of different sizes and/or ages, such as the CIRS ATOM dosimetry phantom family.

CIRS CT imaging QA kit is suitable for CIRS ATOM dosimetry model and CIRS 007TE tissue equivalent CT dose model, and has been widely used in CT dosimetry. The insert included in the kit is designed to study the correlation between image quality and CT dose. The kit provides various targets for the assessment of two important CT performance parameters: low-contrast detectability and spatial resolution of soft tissue and lung regions.

The Model 700-QA is available with four inserts: Lung, Soft Tissue - Cylindrical, Soft Tissue - Spherical, and Soft Tissue - Positive 3D Line Target. The diameters of the spheres and cylinders are chosen to provide a 2:1 volume and cross-sectional area ratio for each pair of adjacent spheres and cylinders, respectively. When ordered with ATOM® inserts can be positioned in the abdomen, liver, mediastinum and lungs.

USACIRS 700QA CT Imaging QA Suite ATOM Phantom Features:

Determining low-contrast detectability

Evaluate spatial resolution

used forATOM or CIRS 007TE Phantom

3 soft tissue inserts

1 lung inserted

 

USACIRS 700QA CT Imaging QA Kit ATOM Phantom Specifications:

lung insertion Overall dimensions: 1.5“Øx2"

Material:

Body: tissue equivalent epoxy lung exhalation

Cylindrical Target: Tissue Equivalent Epoxy

Diameter: 7,5,3.5,2.5,1.8 and 1.2mm

Quantity: diameter three each(3) pieces

Spherical target: Tissue equivalent epoxy resin

Diameter:10, 8, 6.5, 5, 4, 3.2, 2.5 and 2 mm

Quantity: One diameter for each(1)

soft tissue insertion - Cylindrical target

Overall size

1.5“Øx2"

Material:

Body:

Tissue Equivalent Epoxy Soft Tissue

Cylindrical target:

Tissue equivalent epoxy resin - 1% and 2% HU above soft tissue

Diameter:

7,5,3.5,2.5,1.8 and 1.2mm

Quantity:

Each diameter is three (3) pieces

SOFT TISSUE INSERT - *positive 3D line pair target

Overall dimensions:

1.5“Øx2"

Material:

Body:

Tissue Equivalent Epoxy Soft Tissue

*Positive 3D line target:

tissue equivalent epoxy-50 HU higher than soft tissue

Quantity:

Five (5)

Overall dimensions:

5 lines x 5mm wide x 12mm deep

LP / CM:

6,8,10,11 and 12

soft tissue insertion - Spherical target

Overall dimensions:

1.5“Øx2"

Material:

Body:

Tissue Equivalent Epoxy Soft Tissue

Spherical target:

Tissue equivalent epoxy resin - 1% and 2% HU above soft tissue

Diameter:

10, 8, 6.5, 5, 4, 3.2, 2.5 and 2 mm

Quantity:

one for each diameter and contrast (1)

CIRS 700QA CT Imaging QA Kit ATOM Phantom Included

QTY:

Component Description:

1

lung insertion

1

soft tissue insertion - Cylindrical target

1

soft tissue insertion - Spherical target

1

soft tissue insertion - *Positive 3D line-to-target

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.