American CIRS 610 AAPM CT performance phantom
Product model:
Brief description:The AAPM CT Performance Phantom CIRS 610 provides users with a single test object to measure 10 different CT performance parameters. The phantom is designed based on the American Association of Physicists' Medical Task Force guidelines for CT scanner phantom reporting.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
USACIRS 610 AAPM CT Performance Phantom
Product introduction:
The AAPM CT Performance Phantom CIRS 610 provides users with a single test object to measure 10 different CT performance parameters. The phantom is designed based on the American Association of Physicists' Medical Task Force guidelines for CT scanner phantom reporting. The objectives of the report are to (1) define CT scanner performance and (2) describe phantom performance testing methods through the use of specific phantoms.
oneCT value linear inserts, high contrast inserts, and slice thickness inserts are all combined in an 8.5-inch diameter PMMA water tank, equipped with quick-release valves for easy filling and draining. Also included is a 0.25-inch bone equivalent ring that can be used with the insert to evaluate the effectiveness of beam hardening.
Comparative test objects adhered to the bottom, including two rows of diameterCavities from 1 to 0.125 inches, cavity filling is available for a variety of solutions for contrast evaluation.
USACIRS 610 AAPM CT performance phantom test performance:
noise
spatial resolution
Sensitivity(low contrast resolution)
absorbed dose
size dependence
contrast scale
slice thickness
collimation
linearity
Beam width
USASpecific parameters of CIRS 610 AAPM CT performance phantom:
Dimensions: 21.6 cm X 39.4 cm (8.5" OD x 15.5" L)
Weight:7.8 kg (17.25 lb)
Material:PMMA cast - 21.6 OD 20.3 cm ID x 32.4 L
(8.5" OD x 12.75" L)