American CIRS 711-HN head phantom
Product model:
Brief description:The CIRS 711-HN head phantom provides researchers, clinicians and technicians with a consistent tool. It is ideal for determining good system settings, commissioning new equipment, monitoring system performance and training on dental X-ray, panoramic X-ray, CT and cone beam CT procedures.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
USACIRS 711-HN head phantom
Product introduction:
USAThe CIRS 711-HN head phantom is a very realistic maxillofacial model for dental cone beam CT and panoramic X-ray.
Reference standard for radiographic diagnosis of the head. The purpose of this phantom is to assist technical and clinical staff in the selection, monitoring, training and validation of scan parameters commonly used in most radiology procedures requiring fine anatomical detail.
The CIRS 711-HN head phantom provides researchers, clinicians and technicians with a consistent tool. It is ideal for determining good system settings, commissioning new equipment, monitoring system performance and training on dental X-ray, panoramic X-ray, CT and cone beam CT procedures.
The CIRS 711-HN head phantom is constructed of proprietary tissue-equivalent materials. ATOM®max is made of tissue-simulating resin that simulates the X-ray attenuation characteristics of human tissue, CT and treatment energy range (50keV-25MeV).
include detailed3D anthropomorphic anatomy including brain, bones, larynx, trachea, sinuses, nasal cavity and teeth. The bone contains cortical and trabecular separations. Teeth include unique dentin, enamel, and root structures including nerves. The sinus cavity is fully opened. The jaws are slightly open and the front teeth are aligned vertically to replicate the correct positioning of the bite guide. Please note that this product cannot hold an actual bite guide.
Adjustable stand available in cone beamAccurate phantom positioning within CT or panoramic X-ray systems. It can be adjusted on the xyz axes and also rotated around these axes. The head easily screws onto the bracket and locks into place.
USACIRS 711-HN head phantom features:
Includes detailed anatomical features
Frankfurt aircraft identified to ensure proper alignment
Tissue equivalents from 50 keV to 25 MeV
Positioning six degrees of freedom positions
include cases
4 years warranty
Product specifications:
Dimensions of the phantom:9“x 9"x 11.5“
Phantom weight:11 pounds
Bracket weight:7 pounds
USACIRS 711-HN head phantom functions and applications:
entrustX-ray, panoramic X-ray, CT and cone beam CT systems
Learn how to position your head correctly to get a great image
Testing reconstruction techniques and algorithms for implant planning and maxillofacial reconstruction
Train and evaluate personnel during implementation of new equipment and technology
Verify image quality consistency
USACIRS 711-HN head phantom product specifications:
Overall dimensions (approximate only head) | 7.1“x 8.8"x 10.6“ |
phantom weight | 11 pounds |
standing weight | 7 pounds |
Shipping weight | 29 pounds |