LXcan point luminance meter serial number: VD0601400
Product model:
Brief description:LXcan point photometer Serial number: VD0601400 Monochromatic photometer, built-in discrete light tube and screen contact measurement mask, ideal quality control measurement tool that complies with IEC, AAPM and DIN standards Technical specifications: Display: 1.2″TFT (65,000 colors) Sensor consistency: user-defined Distance sensor: ultrasonic distance measurement Target positioning: windowing

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- Radiotherapy three-dimensional water tank is an important equipment in the field of radiotherapy
- Online radiation alarm is the key equipment for modern radiation protection
- Radiation meters protect environmental safety: Popular science on the application of practical equipment for radiation monitoring
- Low contrast detail detection phantom丨Product Encyclopedia
- Surface Contamination Detector Supplier Screening Guide: Key Points to Consider from Qualifications to Services
- Thermoluminescent personal dosimeters can be used in areas such as environmental dose monitoring
- Application of radiotherapy three-dimensional water tank in radiotherapy
- When choosing an explosion-proof radiation measuring instrument suitable for your own use, you need to consider these aspects
- Thermoluminescent dose tablets are a proven dose measurement tool
- How to choose a neutron dose rate meter? Understand the detection principle so that you will not be fooled by the parameter table
Detailed introduction
LXcan point luminance meter serial number: VD0601400
Product introduction
LXcan Point luminance meter serial number:VD0601400
Monochromatic photometer with built-in discrete light tube and screen contact measurement surface
cover, conform toIEC、AAPMandDINThe standard and ideal quality control measurement tool
Technical specifications:
Display:1.2″TFT(6.5Colorful)
Sensor consistency: user-defined
Distance sensor: ultrasonic ranging
Target positioning: windowing
F.O.V.: 1.6º
Measuring range: 0.05 – 10000 cd/m2
Photometry V(λ) uncertainty≤3%
Total uncertainty:≤10%
Data interface:USB; RS 232
Scattered light dissipation: built-in
Weight:450grams