German IBA 38 type line pair card high resolution test card
Product model:
Brief description:The German IBA 38 line pair card is mainly used to test the high resolution of X-ray machines. Measuring range: 0.6-5.0LP/MM, number of groups: 20. The lead foil thickness is 0.1mm and the size is 50X50mm. Resolution range: 0.6-5.0 lp/mm

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- The appropriate light field detection board should be selected according to needs
- How does the German IBA line card evaluate the resolution capability of the X-ray machine?
- Low-contrast detection phantom to protect health
- Analysis of core parameters for purchasing radiation detectors: technical guide from sensitivity to anti-interference ability
- Important equipment for radiation environment monitoring: A brief analysis of the application of KARRAY neutron dose rate meter
- Surface Contamination Detector Supplier Screening Guide: Key Points to Consider from Qualifications to Services
- A thermoluminescence dosimeter is an analytical device used to measure radiation dose
- Nuclear radiation monitoring expert: The technical foundation and market reputation verification of KARRAY Technology’s neutron dose rate meter
- KARRAY Technology: The cutting-edge power of domestic dose area product meters, technical strength and product line analysis
- Radiation detector selection guide: scientific decision-making from needs to application scenarios
Detailed introduction
Applicable toResolution testing and quality control of X-ray imaging and quality assurance of X-ray imaging equipment
germanyIBA 38 type line pair card
Mainly used for testingHigh resolution of X-ray machines.
Measuring range:0.6-5.0LP/MM, 20 groups.
The thickness of lead foil is0.1mm, size is 50X50mm。
Resolution range:0.6-5.0 lp/mm
Type 38 line pair test pattern: selection notes
The original product information describes this model as a line pair test pattern for high-resolution testing of X-ray imaging systems.
- The listed resolution range is 0.6–5.0 lp/mm, with 20 groups.
- The listed lead foil thickness is 0.1 mm and the dimensions are 50 × 50 mm.
- Compare the range, group count, foil thickness and dimensions separately for TYPE39 and Type81. Confirm the required configuration against the relevant model documentation.
Type 38 line-pair pattern: reading the specifications
The existing documentation describes Type 38 as a high-resolution X-ray test pattern. This table organizes the original values for configuration checks.
| Item | Existing site documentation | Check before ordering |
|---|---|---|
| Resolution range | 0.6–5.0 lp/mm | Coverage of the target resolution |
| Pattern groups | 20 | Individual frequencies and markings |
| Lead foil thickness | 0.1 mm | Material, thickness and test conditions |
| Dimensions | 50 × 50 mm | Mounting space and imaging field |
lp/mm means line pairs per millimetre; the number of groups describes the pattern divisions. These values serve different purposes. Also specify the imaging system and intended test method.
Documents to confirm
- A specification sheet for the exact model or order code, including individual frequencies, material and thickness.
- Operating information and available factory or calibration documents, with their applicable model and test scope.
IBA official general library is a manufacturer resource directory. A publicly downloadable Type 38 manufacturer document has not been verified in this review; the table summarizes the existing site documentation.
Documentation checked: 29 October 2026. Confirm the delivered configuration against the quotation and model-specific documents.
Product consultation
- Previous article:American screen adhesion test phantom FFA 4090R
- Next article:German IBA TYPE39 line-to-card



Product consultation
Contact