Product model:
Brief description:CT quality control performance testing phantom: ① The phantom meets the requirements of national standards and can measure: CT linearity, layer thickness, positioning light accuracy, low contrast detectability, high contrast resolution, water CT value, uniformity and noise, inner diameter ≥ 20cm ② CT value linear materials include: air, polyethylene, plexiglass, polytetrafluoroethylene; ③ The angle between the tungsten wire of the layer thickness measurement unit and the straight line at the upper and lower ends of the component is ≥ 26.6°;

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES- This knowledge of CT dose detection phantom is worth learning
- What is the specific role of CT performance testing phantom?
- How effective is the spatial resolution test card in practical applications?
- How does the German IBA line card evaluate the resolution capability of the X-ray machine?
- Safety barriers for working in radiation environments: the practical value of personal dose alarms
- 2026 Radiation Detector Purchase and Avoidance Guide: How does KARRAY Technology solve the industry’s pain points with “technology + service”?
- Online radiation alarm is the key equipment for modern radiation protection
- Thermoluminescent personal dosimeters can be used in areas such as environmental dose monitoring
- Radiotherapy three-dimensional water tank is an important equipment in the field of radiotherapy
- Do you really know about thermoluminescent personal dosimeters?
Detailed introduction
ctQuality control performance testing phantom:
①The phantom meets the requirements of national standards and can measure:CTLinearity, layer thickness, positioning light accuracy, low contrast detectability, high contrast resolution, waterCTvalue, uniformity and noise, inner diameter ≥20cm
②CTValue linear materials include: air, polyethylene, plexiglass, PTFE;
③The angle between the tungsten wire of the layer thickness measuring unit and the straight lines at the upper and lower ends of the component ≥26.6°;
④The high contrast resolution module includes the following line pairs:2.50LP/cm,3.33LP/cm,4.00LP/cm,5.25LP/cm,6.25LP/c-m,7.14LP/cm,8.33LP/cm,10.0LP/cm,11.25LP/cm,16.7LP/cm;
⑤The contrast range of the low contrast resolution module includes:2.0%,1.0%,0.5%,0.25%;
⑥ Low contrast module measurement aperture includes:10mm,7mm,5mm,4mm,3mm,2.5mm,2mm,1.5mm;
⑦The inside of the phantom is pure filled, with a separate layer used to measure uniformity, noise and water.CTvalue;
⑧The phantom should be hung on the head of the bed, and the level can be adjusted with a special spirit level;
⑨CTThe water phantom needs to be built intoCTPerformance inside the phantom