KARRAY / PRODUCT DETAILS

RAD7 radon detector

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

RAD7 radon detector image

RAD7 radon detector

Product model:

Brief description:According to the "Measurement Law of the People's Republic of China" and relevant regulations and technical requirements, the RAD7 electronic radon meter of the American company DURRIDGE has been certified and obtained the meter type approval certificate of the People's Republic of China.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Related articles

RELATED ARTICLES

Detailed introduction

RAD7 radon detector

According to the "Measurement Law of the People's Republic of China" and related regulations and technical requirements, the United StatesDURRIDGE's electronic radon meter RAD7 has been certified and obtained the meter type approval certificate of the People's Republic of China.

Features:

l Radon radiation source finder/Radon gas continuous detector

l Measured radon and thorium can be displayed in the form of spectral curves

l It is the electronic radon detector with the fastest response and the shortest recovery time on the market. It is a portable detector that integrates continuous monitoring of radon gas and detection of radon radiation sources.

l The operation is simple, just follow the prompts of the microcomputer, the measured radon and thorium will be displayed as a spectrum curve, and the data can be output with an infrared printer.

l Meet the U.S.EPA operating standard of 4 pCi/L for 1 hour

l Displays and prints continuously updated radon level values from start to test

l Test results can be displayed on the computer, printed out, and data downloaded

l The spectrum curve shows the accuracy of the instrument in field operation.

l Spectrum Reader:The alpha distribution histogram verifies the radon/thorium content and also verifies the correct operation of Rad7. Correct measurement of alpha particle energy can be used as an energy signature to distinguish the alpha particles of radon and thorium from other alpha particles of the same number.

l Data confidentiality:The "Test Lock" command ensures that your data is not tampered with on the machine

 

                 RAD7 alpha spectrum

 

l Automatic mode: This setting starts using detection mode,Automatically switches to normal mode after 3 hours

l Fast low value detection: in continuous measurement mode,The RAD-7 measures radon at an EPA operating level of 4 pCi/L over 1 hour with a standard error of 2%. Since RAD-7 actually has nobackground design, so it is more sensitive than other electronic radon detectors and can easily measure as low asRadon at 0.1pCi/L level

 

          RAD7 standard installation diagram

Various measurements

Measure air, soil and water (withRADRadon gas in water fittings)

fan surround

0.1-20000pCi/L

Operating principle

Spectral analysis of radon caused by electrostatic accumulation222or radon220The alpha particles emitted are used to calculate the measurement results.

data storage

save1000group/Sub-radon detection data can be found atLCDDisplay data on the screen and print measurement results in infraredor download toPC

spirit sensitive degree

Detector:0.4 counts/min/pCi/L Radon radiation source finder: 0.2 counts/min/pCi/L

Fast low value detection:

In continuous measurement mode,The RAD-7 measures radon at an EPA operating level of 4pCi/L over 1 hour with a standard error of 2%! The background-free design of the RAD-7 instrument gives it excellent sensitivity, up to 0.1 pCi/l.

Recovery time one minute

From half-life toHigh radon exposure value of 3.05 minutesrestore:within 12 minutesrestoreto less than the peak10% within 30 minutesrestoreto the peak1%, from 200 in 1 hour00down to1pCi/L

LCD display

2 lines × 16 letters, simple and easy to read

electricity  source

AC/Battery Power - 5AH 6V battery, auto-charging. Battery continuous working time: 24 hours sampling, 72 hours continuous monitoring

operating environment

temperature: 5°- 40℃ Humidity: 0 - 100%, non-condensing

RS-232 interface

Connect to computer

printer

HP 82240A

weight/size

11 pounds - 9.5" × 7.5"×10.5"

Built-in pump

 Average1 L/minFlow, built-in air filter; inlet and outlet air connectors

Preset measurement

Inhale,1days,2Day, week, user settings, crawl,Wat-40、Wat-250, thoron gas.

Carrying case

high density polyethylene

Technical parameters:

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7