American CAPINTEC CRC-Ultra multifunctional activity meter
Product model:
Brief description:CRC-Ultra can be combined with standard 12 atmosphere pressure and 5 atmosphere pressure PET ionization chambers, using the latest special sealing and pressurized Capintec ionization chamber. Epson printer is an excellent partner of CRC-Ultra. Requires small and compact space, easy to install red or black ribbon CRC-Ultra can also be equipped with Okidata, HP Deskjet and Epaon Stylus printers through USB printer interface

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
USACAPINTEC CRC-Ultra multifunctional activity meter
Product introduction:
l CRC-Ultra can be combined with standard 12 atmospheres and 5 atmospheres PET ionization chambers, using the latest dedicated sealed and pressurized Capintec ionization chambers
l Epson printers are an excellent partner for CRC-Ultra. Requires small and compact space, easy to install red or black ribbon
l CRC-Ultra can also be equipped with Okidata, HP Deskjet and Epaon Stylus printers via USB printer interface
l Enhanced features include connecting remote monitors and printers
l CRC-Ultra activity meter has intelligent remote display function
l Remote control can be installed at a distance from the main application unit100 feet away
l It switches eight independent nuclide buttons for each ionization chamber
l Measures bias voltage, auto-zeroes, auto-backgrounds, and performs accuracy tests
l
![]() |
Interface:RS-232 or UCS bidirectional interface with software-controlled switching function
Product features:
l QC module:
l Automatic zero, automatic background, bias voltage, accuracy, stability, linearity, geometry;
l Two or three test strip test models; molybdenum and molybdenum analysis; self-test and reference source data recording
l Nuclide:
l exceed200 types of nuclides detected;
l Can be stored80 nuclides and their half-lives are used for decay calculations;
l Up to8 preset keys and 9 user-defined keys
l Practicality:
l provideTwo units: Ci and Bq;
l Decay calculation function;
l Ci and Bq conversion function; future time calculation
Introduction to well counter:
l Automatic calibration, including energy calibration and stability calibration
l Displays the net count after background subtraction
l Fixation of Six PathsMAC analysis
l User-defined wipe test method
l Counting error display
l Mark high value trigger limit
l Vial Blood Volume and Red Blood Cell Count Laboratory Tests
Beta Counter Introduction:
l Automatic calibration, including energy calibration and stability calibration
l Displays the net count after background subtraction
l Fixation of Six PathsMAC analysis
l Store calibration factors for bottle and syringe reference sources for each nuclide
l storageDetection efficiency at 10cm and 20cm positions
l Count rate correction
Technical parameters:
Product specifications: | |
CRC-Ultra: readout unit | Automated quality control procedures include linearity, geometry, and strip testing, as well as total volume and single or multi-bottle dosing modules |
Design includes tilt-table display, user-adjustable backlighting, easy-to-read keypad and key tone | |
Height: | 15.2cm |
Width: | 27.6cm |
Length: | 25.4cm |
Weight: | 1.9Kg |
Input voltage: | 110-240V,0.5A,50/60Hz |
CRC-Ultra: expansion unit | Extension modules are available to accommodate more than two ionization chambers (forA combination of 6 additional ionization chambers with reserved ports is required. |
Height: | 9.4cm |
Width: | 27.6cm |
Length: | 27.0cm |
Weight: | 1.2Kg |
Ionization chamber assembly: | CRC-Ultra can be combined with a 12 atmosphere pressure standard ionization chamber and a 5 atmosphere pressure PET ionization chamber. |
Additional ionization chambers are firmware upgradeable | |
Height: | 45.7cm |
Diameter: | 15.2cm |
Weight: | 12.8Kg |
Well Counter: | CRC-Ultra well counter options include wipe testing and laboratory testing capabilities. |
Height: | 23.8cm |
Diameter: | 17.2cm |
Weight: | 6.9Kg |
Beta Detector: | CRC-Ultra’s Beta Detector is the first choice for high-energy Beta ray measurements |
Height: | 14.1cm |
Width: | 8.4cm |
Length: | 45.7cm |
Weight: | 8.4Kg |
Hardware features: | |
activity meter | |
Standard12 atmosphere pressure ionization chamber: | maximum value 300GBq (8.0Ci molybdenum analysis tank), |
maximum resolution0.001MBq(0.01μCi), | |
PET ionization chamber: | maximum500GBq(12Ci) |
0.01MBq(0.1μCi) | |
Measurement repeatability: | <+/-0.5% |
Electrometer accuracy: | <2% |
Linearity: | +/-2% |
Response time: | 2s |
Cable length: | 12 feet standard cable length, optional extension cable up to 200 feet |
well counter | |
Type: | 1.5-inch NaI crystal well type scintillation detector |
Energy screening: | fixed rangeMCA energy window 15-100,100-200,200-400,400-660,660-800,800keV |
Coaxial cable length: | 2.7m |
Lead Shield: | 1.3cm including top shielded lead coating, 0.5" secondary lead shield optional |
Beta counter | |
Type: | Thin layers optimized for bremsstrahlung sensitivityNaI scintillation counter |
Sample distance: | 10cm and 20cm |
Count rate: | Reachable50,000cps (25 to 100mCi pure Beta radiation) |
Shield: | 1.3cm lead collimator |
Coaxial cable length: | 2.9m |
Lead Shield: | 0.5-inch auxiliary lead shield optional |
Multiple ionization chambers: | a well detector and aThe Beta detector is directly connected to the readout unit. |
Additional ionization chambers require an expansion unit | |
Product consultation
- Previous article:American CAPINTEC CRC-PC SMART smart activity meter
- Next article:RAD7 radon detector



Product consultation
Contact