AT1316 Whole Body Radiation Counter
Product model:
Brief description:300Bq for 3 minutes, measuring up to 15 people per hour Quick and flexible measurement of radionuclides in the body, internal exposure dose assessment The whole body counter is based on a combination of total γ radionuclide detection and energy spectrum data processing software analysis Provides a counting evaluation of the human body characteristics of personal internal exposure pollution

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
AT1316 Whole Body Radiation Counter
Product introduction
l 300Bq 3 minutes, up to 15 people can be measured per hour
l Quickly and flexibly measure radionuclides in the body and evaluate internal radiation dose
l Whole body counters are based on totalCombination of gamma radionuclide detection and energy spectrum data processing software analysis
l Provides a count evaluation of the human body characteristics of personal internal exposure pollution
Application areas
l Monitoring of the public and workers during and after a radiation incident
l Dose Burden Control of Internal Radionuclide Exposure
l Monitoring of nuclear industry and open source workers
Product features
l Stable spectrum path
l Energy Spectroscopy and Radiation Measurement Modes
l Maximum likelihood method effectively processes energy spectrum data
l Monitor radionuclides in radiation measurement mode
l Radionuclide identification
l Calculation of expected internal radiation effective dose
l Flexible program control/Whole Body Counting Functions/Database Management and Results Reporting
l Compact chair design
l Generate functional mode of operating energy spectrum to quickly detect background energy spectrum
Technical parameters
Detect radiation energy range | 0.05 - 3 MeV |
inside the bodyMinimum measured activity of 137Cs (3 minutes) | 300 Bq |
Radionuclide measurement in standard mode | 137Cs, 40K |
Measurement geometry(sitting on the sofa) | angle of light 100° |
overall measurement error | ±15% |
MCA | 1024 channels |
internal nonlinearity | no more than ±1% |
Operating mode setting time | 10 min |
continuous operation time | 24 h |
Reading instability | no more than ±3% |
Quick control check | 15 people/hour |
Operating temperature range | 10 - 35°C |
relative humidity | 80 % |
alternating current | 220 (+22;-33) V, 50 Hz |
power demand | no greater than200 VA |
Current damage protection level | 1, type B |
Radiated interference standards | CEI/IEC CISPR 22:1997 |
EMC compatibility | CEI/IEC 61000-4-2:1995 |
weight | 250 kg |
Minimum installation area | 2000 X1500 mm |
Product consultation
- Previous article:AT1315 laboratory gamma, beta energy spectrometer
- Next article:AT1320 Y activity meter



Product consultation
Contact