KARRAY / PRODUCT DETAILS

AT1316 Whole Body Radiation Counter

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

AT1316 Whole Body Radiation Counter image

AT1316 Whole Body Radiation Counter

Product model:

Brief description:300Bq for 3 minutes, measuring up to 15 people per hour Quick and flexible measurement of radionuclides in the body, internal exposure dose assessment The whole body counter is based on a combination of total γ radionuclide detection and energy spectrum data processing software analysis Provides a counting evaluation of the human body characteristics of personal internal exposure pollution

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Related articles

RELATED ARTICLES

Detailed introduction

AT1316 Whole Body Radiation Counter

Product introduction

l 300Bq 3 minutes, up to 15 people can be measured per hour

l Quickly and flexibly measure radionuclides in the body and evaluate internal radiation dose

l Whole body counters are based on totalCombination of gamma radionuclide detection and energy spectrum data processing software analysis

l Provides a count evaluation of the human body characteristics of personal internal exposure pollution

Application areas

l Monitoring of the public and workers during and after a radiation incident

l Dose Burden Control of Internal Radionuclide Exposure

l Monitoring of nuclear industry and open source workers

Product features

l Stable spectrum path

l Energy Spectroscopy and Radiation Measurement Modes

l Maximum likelihood method effectively processes energy spectrum data

l Monitor radionuclides in radiation measurement mode

l Radionuclide identification

l Calculation of expected internal radiation effective dose

l Flexible program control/Whole Body Counting Functions/Database Management and Results Reporting

l Compact chair design

l Generate functional mode of operating energy spectrum to quickly detect background energy spectrum

Technical parameters

Detect radiation energy range

0.05 - 3 MeV 

inside the bodyMinimum measured activity of 137Cs (3 minutes)

300 Bq

Radionuclide measurement in standard mode

137Cs, 40K 

Measurement geometry(sitting on the sofa)

angle of light 100° 

overall measurement error

±15% 

MCA

1024 channels

internal nonlinearity

no more than ±1%

Operating mode setting time

10 min 

continuous operation time

24 h 

Reading instability

no more than ±3% 

Quick control check

15 people/hour

Operating temperature range

10 - 35°C 

relative humidity

80 %

alternating current

220 (+22;-33) V, 50 Hz

power demand

no greater than200 VA 

Current damage protection level

1, type B

Radiated interference standards

CEI/IEC CISPR 22:1997

EMC compatibility

CEI/IEC 61000-4-2:1995 
IEC 61000-4-4:1995
IEC 61000-4-11:1994

weight

250 kg

Minimum installation area

2000 X1500 mm

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7