American CIRS 069 Doppler ultrasound blood flow simulator
Product model:
Brief description:The CIRS 069 Doppler ultrasound blood flow simulator is designed to simulate blood flow in tissue simulation phantoms and can be used to perform quality assurance testing of Doppler ultrasound equipment. Two tests that are very common are sensitivity and speed accuracy, but many other useful tests are described in the literature (see References).

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
USACIRS 069Doppler ultrasound blood flow simulator
Product introduction:
The CIRS 069 Doppler ultrasound blood flow simulator is designed to simulate blood flow in tissue simulation phantoms and can be used to perform quality assurance testing of Doppler ultrasound equipment. Two tests that are very common are sensitivity and speed accuracy, but many other useful tests are described in the literature (see References).
The CIRS 069 Doppler Ultrasound Blood Flow Simulator includes a blood vessel simulation ultrasound-compatible tube that mimics a human blood flow model and enters the model at an angle. The phantom has both top and bottom scanning surfaces, allowing testing at different depth and orientation angles. This makes the phantom suitable for testing peripheral blood flow and deeper abdominal vessels. The phantom was filled with Zerdine® tissue-mimetic gel with an attenuation of 1540 m/s, 0.7 dB/cm/MHz and a backscatter contrast designed to match the acoustic velocity of the liver. It is housed in sturdy ABS plastic for added durability. Customers wishing to combine B-mode quality assurance capabilities with Doppler testing may request custom phantoms to include wire, grayscale and anechoic targets.
USACIRS 069 Doppler ultrasound blood flow simulator product features:
Peristaltic pumps can provideFlow rate of 0.5 to 12.5ml/s, which means the average flow rate is 2-70cm/s. (Due to the influence of laminar flow and pulsating flow, the peak flow rate will be 2-4 times greater than the average flow rate).
pre-filledReservoir for CIRS blood simulant fluid. Replacement fluid can be ordered separately.
Pulsation dampers convert pulsating flow from a peristaltic pump into a constant flow rate.
Convenient color-coded tube quick disconnect fittings
The convenient hard-shell carrying case design keeps the entire system pre-configured inside the case.
USACIRS 069 Doppler ultrasound blood flow simulator technical parameters:
CIRS 069 Doppler Ultrasound Blood Flow Simulator Product Specifications | ||
Doppler flow pump | ||
Motor type | stepper motor | |
Motor steps per revolution | 200 | |
Micro | 1/8 to 1/1 depending on motor speed | |
DC connector | 2.1mm, *center positiove | |
DC connector voltage | 24V DC full load | |
Ampere | When fully loaded, it is900mA | |
Power supply type | Unregulated Linear External Wall Adapter, Home and Power Supply Specific | |
Power output rating | 24V DC @ 1A | |
Overall dimensions | 7 3/4" x 5 1/4" x 5 3/4" high | |
weight | 4.51 lbs (2.05 kg) | |
great speed | 372 RPM | |
very low speed | 0.0168 RPM | |
Very high draw rate | use3/16 ID tubing 775.2 mL/min | |
Very small margin | use3/16 ID tubing 0.035mL/minute | |
blood simulated fluid | ||
Properties | human blood (37°C) | Blood simulated fluid (22°C) |
viscosity (mPa) | 3 | 4±0.5 |
speed (m / s) | 1583 | 1570±30 |
decay (dB / cm / MHz) | 0.15 | <0.1 |
Backscatter (f 4 m -1 sr 1) | 4x10 -31 | Not measured |
fluid properties | non-Newtonian | newton |
"Validation of a Novel Blood Simulating Fluid for Doppler Flow Test Subjects", | ||
tissue equivalent phantom | ||
Overall dimensions | 20×12.5×27.5cm | |
pipe | Internal dimensions:3/16“ | |
Scan surface | Saran laminate film: 12.5 x 17.5 cm | |
background material | Zerdine ® | |