CIRS 731-HN head phantom
Product model:
Brief description:The CIRS 731-HN head phantom is an anthropomorphic head phantom designed for commissioning and treatment planning system (TPS) validation with any conformal or IMRT proton therapy system1. The phantom is constructed of materials equivalent to CIRS tissue that mimic reference tissue within 1.5% for protons and 1% for photons from 1.5 KeV to 15 MeV.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
CIRS 731-HN head phantom
Product details
—Tissue equivalence of proton and photon therapy
The CIRS 731-HN head phantom is an anthropomorphic head phantom designed for commissioning and treatment planning system (TPS) validation with any conformal or IMRT proton therapy system1.
The motif is equivalent toCIRS tissue is composed of materials that mimic reference tissue within 1.5% for protons from 1.5 KeV to 15 MeV and 1% for photons. The proton therapy head can be used in all standard IMRT procedures from CT image acquisition to verification of proton beam delivery1,3.
The detailed tissue equivalence of the internal structures makes this phantom ideal for evaluating treatment plans in locations with high density gradients, which is particularly important in proton therapy, such as stoma and bone structures. Internal structures include the brain, bones with cortical and trabecular distinctions, larynx, trachea, fully open sinus cavities, nasal cavity, and oral cavity, and teeth with distinct dentine, enamel, and root structures.
The Model 731-HN approximates the average male head in size and structure, allowing for intuitive setup using any patient positioning or immobilization device.
Starting from the approximate center of the sagittal plane, place half of the phantom at three film positions in the craniocaudal direction.Section in 2 cm increments. Because the slices are orthogonal to the CT axial plane, artifacts caused by residual air gaps are significantly reduced compared to standard axial slices.
By adding tungstenThe BB was placed in the molar and the titanium prosthesis was fixed to the C3 and C5 vertebrae with two screws to enhance the commissioning of the proton system.
CIRS 731-HN head mold features
Detailed internal anatomy, including bones and air
Three film positions in the sagittal direction
Organizational equivalence of protons and photons
Dental fillings and spinal prostheses
Product consultation
- Previous article:CIRS 071B image-guided abdominal puncture phantom product
- Next article:CIRS 801-P male simulated pelvis phantom



Product consultation