Interceptor gamma spectrometer
Product model:
Brief description:Interceptor is a new generation of high-performance personal radiation detector (SPRD) with spectrometer Combines personal radiation detection instrument (PRD) and isotope identification capability (RIID) Has good on-site measurement sensitivity

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
Interceptor gamma spectrometer
Product introduction:
l The Interceptor is a new generation of high-performance personal radiation detectors (SPRDs) with spectrometers
l Incorporated personal radiation detection instrument(PRD) and isotope identification capability (RIID)
l Has good on-site measurement sensitivity
l Accurate on-site isotope identification capabilities and excellent cost performance
l The instrument uses large-volume and high-efficiency cadmium zinc telluride (CZT) detector
l withCompared with NaI (Tl) detectors, the energy resolution is several times better, which greatly improves the measurement accuracy and reduces false and missed measurements.
l The electronics part is based onMCA with 2048-channel digital signal processing (DSP) and energy-compensated dose algorithm
l Configured with3He neutron detector with high sensitivity to neutrons without Gamma crosstalk
l with other personal radiation detectors (PRD), Interceptor has excellent Gamma and neutron measurement sensitivity, and can identify nuclides quickly and accurately.
l The sturdy and reliable 2-in-1 design makes the cost of use very low.
l Interceptor provides users with the ability to detect, identify suspected radioactive sources, and transmit information. It can be equipped with digital cameras and Bluetooth communication components to transmit on-site information to third parties
l Interceptor uses low-power technology to greatly increase battery life
Product features:
l SPRD and RIID capabilities
l Integrated design with great versatility and versatility
l Simple and convenient operation, three-button operation
l There is a high density on topLED, the front end is a large-area high-brightness full-color VGA TFT display that can be rotated 180 degrees, making it easy to browse measurement data at any angle
l Equipped with speakers that can guide and alarm by sound. Alarm tone is proportional to alarm level
l Optional built-inVGA digital cameras, microphones and audio recorders record results, which can provide rich information on the suspected measurement object
l No computer required
l Fast and efficient communication and recording of results
l 128Mb SD memory card (expandable) ensures storage of thousands of measurements
l HaveUSB interface
l Bluetooth wireless components can be configured to connect to third parties such as expert systems through mobile phones or satellite phones to achieve instant analysis.
l conform toANSI42.32 and CE standards
Product application:
l Nuclear radiation measurement
l Nuclear safeguards and nuclear material control
l Measurement and verification of spent fuel
l Inspections against illegal smuggling of nuclear materials (airports, borders, etc.)
l process control
Technical parameters:
energy range | 25Kev~3Mev |
Sensitivity | 1.5cps/uR/h, 1.2cps/nv |
Protection level | IP 65 dustproof and waterproof design |
Operating temperature range | -20 oC~50oC |
relative humidity | Available95% |
Impact protection | ProtectiveDropped from a height of 1.5 meters to the concrete floor |
power supply | Lithium rechargeable battery or3 AAA ordinary batteries |
detector | High efficiency Large sizeCZT detector |
He3 neutron detector | 8 atm., ½" dia. x 2.6" at 1.2 cps/nv |
Interceptor G | gamma detector |
Interceptor GN | |Seed Detector |
Interceptor Gid | Advancedγ detector (discrimination function) |
Interceptor GNid | Gamma neutron detector (discrimination function) |
Size | 112X61X25mm |
weight | less than250g |
Product consultation
- Previous article:Harshaw acral dosing element
- Next article:MDS vehicle-mounted and airborne mobile radiation search system



Product consultation
Contact