
ISO-CARTTM-85 Mobile Radioactive Waste Detection System
Product model:
Brief description:Turnkey product, the system has been calibrated before leaving the factory, and the IDM integrated electro-cooling spectrometer can be used right out of the box. The new modular collimator analysis is traceable to internationally recognized laboratories.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
ISO-CARTTM-85 Mobile Radioactive Waste Detection System
Overall system characteristics
Turnkey product, the system has been calibrated and started before leaving the factory.Ready to use
IDM Integrated electrorefrigeration spectrometer, new modular collimatorAnalyzes traceable to internationally recognized laboratories
Flexible orientation adjustment,light weight
Various measurement objects:trash can/cabinet/Plane/pipe/bottle
ISO-CAT-II
Detector height:0.38m~1.2m AdjustableDetector angle:0~1800 Adjustable
The distance between front and rear wheels is adjustable(782~889mm)Adjustable rear wheel spacing(686~889mm)
Detector is easy to remove and install
Maximum size : 1324mmL × 889mmW × 1300mmH:weight:63.5kg
l Can match DETECTIVE/Trans-SPEC and traditional liquid nitrogen refrigeration high-purity germanium spectrometer
IDM-200-V
l Highly integrated integrated spectrometer,Includes detectors, electric coolers and digitalMCA
l The crystal size isΦ 85mm×L30mm(The relative detection efficiency is greater than50%),Large effective detection area,In low and medium energysegment has very good actual detection efficiency
l Electronics usesORTECAll new technologies on today's digital spectrometers have performance equivalent toORTECofDSPEC-jr2.0
l AC power supply,Low power consumption,The system power at operating temperature is approximately50W
l
Built-in battery,Can keep the instrument working for three hours,External battery pack works18hours. Connect to alternating current and work continuously
l Refrigeration can be started at any time during any stage of crystal recovery
l USB2.0Communication interface,All functions are controlled by computer
l solid,Earthquake and compression resistance
l Can be configured as an on-site laboratory
ISO-Plus Software
l Based on tens of thousands of actual sample test data
l under a software interface,Input the measurement object template type, content matrix, central axis offset, detection distance, packaging material/Density/Thickness, the system will automatically give the correction factor and compare the measured spectrum When calculating the peak area of a graph, the corrected results are automatically given.
l The system only requires a mixyBasic calibration of nuclide point source,by ORTEC Completed before shipment
l Flexible reporting
![]() |
minimum detection limit(MDA) depends on many factors:The energy of the nuclide of interest, the density and uniformity of the sample matrix, the volumeThe material of the device,(Measurement of waste bins and other sites)field of view and the background of the environment. relatively speaking,ISO-CART-85 systemThe measurement conditions for bottled samples are relatively fixed.
AboutISO-CART-85 The minimum detection limit of the system, the following is a rough reference: for bottled density0.3-0.4g/cc lightweight sample, Measurement time 2000 seconds,Yes Cs-137,MDA approx. 3.5bq/kg,Yes Co-60,MDA approx. 4.4 bq/kg: density in barrel 0.3-0.4g/cc lightweight sample,Measurement time2000 seconds,YesCs-137,MDA approx.2-4bq/kg,YesCo-60,MDA approx.2.5-5.5bq/kg:
![]() |
Configuration and ordering information:
ISO-CART-85-PC(departmentsystem): ISO-CART-II Tipcar,IDM-200-V onebodyizationelectricitysystemcoldhighpuregermaniumLordmachine(IDM-200-V),
Host, collimator and trolley fixing device(IDM-200-V-ISO-2-DCC) , Complete set of shielded collimators(ISO-2-IDM-SHD),version
ISOTOPIC Field Measurement Software Package(ISOTOPIC),Factory point source efficiency curve characterization(ISO-CAL),Laptop.
ISO-2-IDM-SHD: Complete set of collimator,Contains 1 a 2 inches(Copper-tin lining)Stainless steel field of view collimator(ISO-2-IDM-FOV-2), 1a 4 inch field of view collimator(ISO-2-IDM-FOV-4),1 a 6 inch field of view collimator(ISO-2-IDM-FOV-6),and 3 a 2 inches long x1 inch thick lead shielding tube(ISO-2-IDM-SHD-2)。

ISO-2-IDM-SHD-EXT:Bottled sample measurement supporting device,Contains 6 a 1 Liter vial.
3 a ISO-2-IDM-SHD-2 Shielding tube set | ||
at 1 a ISO-2-IDM-FOV-6 collimator | ||
ISO-CART-II Assembly DETECTIVE or Trans-SPEC
ISO-ADAPT100:Installation accessories(screw hole/Bolts etc.),Yes-100 sequence:
ISO-ADAPT-MICRO:Installation accessories(screw hole/Bolts etc.),Yes Micro-sequence:
TSP-ISO-DCC:Host and trolley connection/fixtures
TSP-ISO-SHD-3: Lead shielded collimator(3 inches long x 2 inches thick):
TSP-ISO-SHD-2: Lead shielded collimator( 2 inches long x 2 inches thick), Can be superimposed on
TSP-ISO-SHD-3
ISO-CART-II Assembly of high-purity germanium for liquid nitrogen refrigeration
ISO-DCC:Host and trolley connection/fixtures:
ISO-LASERMETER & ISO-LSRMTR-ADAPT: Laser range finder and fixtures:
ISO-WIRELESS:Wireless control and transmission options,Laptop included:
SHD-1:5/8 inch lead shielded collimator:SHD-2:Tungsten shielded collimator:SHD-3:1.8 Englishinch lead shielded collimator
ISO-DEWAR:Liquid nitrogen filling device(including 50 Liter storage and transportation dewar, liquid nitrogen extraction device and hose)
ISO-TURNTABLE-240 & ISO-TURNTABLE-OPT2:Waste barrel rotating device and remote
controller
![]() |
![]() |
![]() |
Product consultation
- Previous article:GEM30-76 High Purity Germanium Gamma Spectrometer
- Next article:NAI-SS mobile patrol system



Product consultation
Contact







