Product model:

Brief description:Turnkey product, the system has been calibrated before leaving the factory, and the IDM integrated electro-cooling spectrometer can be used right out of the box. The new modular collimator analysis is traceable to internationally recognized laboratories.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Related articles

RELATED ARTICLES

Detailed introduction

ISO-CARTTM-85 Mobile Radioactive Waste Detection System

Overall system characteristics

Turnkey product, the system has been calibrated and started before leaving the factory.Ready to use

IDM Integrated electrorefrigeration spectrometer, new modular collimatorAnalyzes traceable to internationally recognized laboratories

Flexible orientation adjustment,light weight

Various measurement objects:trash can/cabinet/Plane/pipe/bottle

ISO-CAT-II

Detector height:0.38m~1.2m AdjustableDetector angle:0~1800 Adjustable

The distance between front and rear wheels is adjustable(782~889mm)Adjustable rear wheel spacing(686~889mm)

Detector is easy to remove and install

Maximum size : 1324mmL × 889mmW × 1300mmH:weight:63.5kg

l Can match DETECTIVE/Trans-SPEC and traditional liquid nitrogen refrigeration high-purity germanium spectrometer

IDM-200-V

l Highly integrated integrated spectrometer,Includes detectors, electric coolers and digitalMCA

l The crystal size isΦ 85mm×L30mm(The relative detection efficiency is greater than50%),Large effective detection area,In low and medium energysegment has very good actual detection efficiency

l Electronics usesORTECAll new technologies on today's digital spectrometers have performance equivalent toORTECofDSPEC-jr2.0

l AC power supply,Low power consumption,The system power at operating temperature is approximately50W

l Built-in battery,Can keep the instrument working for three hours,External battery pack works18hours. Connect to alternating current and work continuously

l Refrigeration can be started at any time during any stage of crystal recovery

l USB2.0Communication interface,All functions are controlled by computer

l solid,Earthquake and compression resistance

l Can be configured as an on-site laboratory

ISO-Plus Software

l Based on tens of thousands of actual sample test data

l under a software interface,Input the measurement object template type, content matrix, central axis offset, detection distance, packaging material/Density/Thickness, the system will automatically give the correction factor and compare the measured spectrum When calculating the peak area of a graph, the corrected results are automatically given.

l The system only requires a mixyBasic calibration of nuclide point source,by ORTEC Completed before shipment

l Flexible reporting




minimum detection limit(MDA) depends on many factors:The energy of the nuclide of interest, the density and uniformity of the sample matrix, the volumeThe material of the device,(Measurement of waste bins and other sites)field of view and the background of the environment. relatively speaking,ISO-CART-85  systemThe measurement conditions for bottled samples are relatively fixed.

AboutISO-CART-85 The minimum detection limit of the system, the following is a rough reference: for bottled density0.3-0.4g/cc lightweight sample, Measurement time 2000  seconds,Yes Cs-137,MDA  approx. 3.5bq/kg,Yes Co-60,MDA  approx. 4.4  bq/kg: density in barrel 0.3-0.4g/cc lightweight sample,Measurement time2000 seconds,YesCs-137,MDA approx.2-4bq/kg,YesCo-60,MDA approx.2.5-5.5bq/kg:




Configuration and ordering information:

ISO-CART-85-PC(departmentsystem): ISO-CART-II Tipcar,IDM-200-V onebodyizationelectricitysystemcoldhighpuregermaniumLordmachine(IDM-200-V),

Host, collimator and trolley fixing device(IDM-200-V-ISO-2-DCC)  , Complete set of shielded collimators(ISO-2-IDM-SHD),version

ISOTOPIC Field Measurement Software Package(ISOTOPIC),Factory point source efficiency curve characterization(ISO-CAL),Laptop.

ISO-2-IDM-SHD:  Complete set of collimator,Contains 1 a 2 inches(Copper-tin lining)Stainless steel field of view collimator(ISO-2-IDM-FOV-2), 1a 4 inch field of view collimator(ISO-2-IDM-FOV-4),1 a 6 inch field of view collimator(ISO-2-IDM-FOV-6),and 3 a 2 inches long x1 inch thick lead shielding tube(ISO-2-IDM-SHD-2)。

ISO-2-IDM-SHD-EXT:Bottled sample measurement supporting device,Contains 6 a 1 Liter vial.

3 a ISO-2-IDM-SHD-2 Shielding tube set


at 1 a ISO-2-IDM-FOV-6 collimator


ISO-CART-II Assembly DETECTIVE or Trans-SPEC

ISO-ADAPT100:Installation accessories(screw hole/Bolts etc.),Yes-100 sequence:

ISO-ADAPT-MICRO:Installation accessories(screw hole/Bolts etc.),Yes Micro-sequence:

TSP-ISO-DCC:Host and trolley connection/fixtures

TSP-ISO-SHD-3:  Lead shielded collimator(3 inches long x 2 inches thick):

TSP-ISO-SHD-2:   Lead shielded collimator( 2   inches long x   2   inches thick), Can be superimposed on

TSP-ISO-SHD-3

ISO-CART-II Assembly of high-purity germanium for liquid nitrogen refrigeration

ISO-DCC:Host and trolley connection/fixtures:

ISO-LASERMETER & ISO-LSRMTR-ADAPT: Laser range finder and fixtures:

ISO-WIRELESS:Wireless control and transmission options,Laptop included:

SHD-1:5/8 inch lead shielded collimator:SHD-2:Tungsten shielded collimator:SHD-3:1.8 Englishinch lead shielded collimator

ISO-DEWAR:Liquid nitrogen filling device(including 50 Liter storage and transportation dewar, liquid nitrogen extraction device and hose)

ISO-TURNTABLE-240 & ISO-TURNTABLE-OPT2:Waste barrel rotating device and remote

controller










Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.