German AUTOMESS 6150AD5/6150AD6 dose rate meter
Product model:
Brief description:6150AD5 portable environmental

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
germanyAUTOMESS 6150AD5/6150AD6/6150ad-t/6150ad-19 dose rate meter
Product introduction:
l 6150AD5 portable environmental
l The 6150AD5 portable environmental automess supplies special cables in standard lengths from 1.25 meters, 3 meters, 10 meters, 20 meters, 75 meters and 100 meters from stock
Product radiation amount:
l Unless otherwise stated,6150AD and probes are designed for photon dose equivalent (rate) Hx; H*(10) series models with suffix "/H" or "/E" are designed for detection of environmental dose equivalent (rate); "/H" The only difference between "/E" and "/E" is their compatibility with the probe; the "/E" model probe can only be used with the 6150AD host with the "/E" type suffix, and the "/H" model probe can only be used with the "/E" type host
l Note:The difference between Hx and H*(10) is not only the level of photon energy energy response, but also the difference in display units; the following table shows the 6150AD meter and probe compatibility
Probe6150ADn, 6150ADn/H table 6150ADn/E table:
l Sievert probes are neither /H nor /E models (i.e., Hx).
l Sievert probe/H type (i.e. H*(10)) available
l Sievert Probe/Type E (i.e. H*(10)) No Yes
l pulse probe(s-1) Yes Yes
Product model differences:
l the6150ADn series refers to the series models from 6150AD1-6150AD6 (where n represents 1-6)
l 6150AD1/3/5 has the same range from up to 1Sv/h, and their difference lies in the reading method and function; 6150AD3 is an upgraded version of 6150AD1, supporting the application of software (EPROM); 6150AD5 is an upgraded version of 6150AD3, which can be matched with the 6150AD-B scintillator detector for the detection of leakage pollution; similarly, 6150AD2/4/6 has the function from up to 10mSv/h has the same range, among which 6150AD4 is an upgraded version of 6150AD2, and 6150AD6 is an upgraded version of 6150AD3, which can be matched with 6150AD-B scintillator detector; the models from 6150AD1-6150AD4 are obsolete (but are still in use, especially the models 6150AD1 and 6150AD2 with simple functions and easy operation, are affected by user favorite); the table below summarizes the basic features of all models from 6150AD1-6
6150AD5 dose rate meter (high):
l is the detection of photon radiation(gamma and
l Simulation range 1µSv/h-1000mSv/h
l Number range 0.1µSv/h-999mSv/h
l energy range 45keV-3MeV(6150AD5)
l 45keV-2.6MeV(6150AD5/H,6150AD5/ E)
l - Hx type (compatible with all probes except /E type): 6150AD5
l - H*(10) type (compatible with all probes except /E type): 6150AD5/H
l - Type H*(10) (compatible with pulse probes and /E probes): 6150AD5/E
6150AD-15 GAMMA detection probe:
l High dose rate photon radiation probes for detectionGamma and X-rays, powered by 6150AD
l Simulation range 0.1mSv/h-10Sv/h
l Number range 0.01mSv/h-9.99Sv/h
l energy range 65keV-3MeV
l - Type Hx (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-15
l - Type H*(10) (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-15/H
l - H*(10) type (only compatible with 6150ADn/E table): 6150AD-15/E
6150AD6 dose rate meter (low):
l is the detection of photon radiation(gamma and
l Simulation range 0.1µSv/h-10mSv/h
l Number range 0.01µSv/h-9.99mSv/h
l energy range 60keV-1.3MeV
l - Hx type (compatible with all probes except /E type): 6150AD6
l - H*(10) type (compatible with all probes except /E type): 6150AD6/H
l - Type H*(10) (compatible with pulse probes and /E probes): 6150AD6/E
6150AD-18 GAMMA detection probe:
l Low dose rate photon radiation probes for detectionGamma and X-rays, powered by 6150AD
l Simulation range 0.1µSv/h-10mSv/h
l Number range 0.01µSv/h-9.99mSv/h
l energy range 65keV-1.3MeV
l - Type Hx (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-18
l - Type H*(10) (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-18/H
l - H*(10) type (only compatible with 6150ADn/E table): 6150AD-18/E
6150AD-17α-β-γ detection probe:
l Wipe test probe, compatible with anyModel 6150AD dose rate meter, powered by 6150AD
l Simulation range 0.1s-1-10ks-1
l Number range 0.01s-1-9.99ks-1
6150AD-b ionization chamber scintillator probe:
l It detects photon radiation3" x 3" plastic scintillator probe; for detecting gamma and X-rays, powered by 6150AD, includes spiral probe cable
l Simulation range 10nSv/h-100µSv/h
l Number range 1nSv/h-99.99µSv/h
l energy range 23keV-7MeV(6150AD-b)
l 20keV-7MeV(6150AD-b/H, 6150AD-b/E)
l - Hx type (compatible with 6150AD5(/H) and 6150AD6(/H) tables): 6150AD-b
l - H*(10) type (compatible with 6150AD5(/H) and 6150AD6(/H) tables): 6150AD-b/H
l - H*(10) type (compatible with 6150AD5(/E) and 6150AD6(/E) tables): 6150AD-b/E
6150AD-19 BETA-GAMMA Liquid Sample Probe:
l Liquid radiation detection probe, compatible with all dose rate meters, manufactured by6150AD power supply. (discontinued)
6150AD-K Surface Contamination Detection Probe:
l It's a large areaα, β, and γ ray counter tubes, compatible with all 6150AD dose rate meters, powered by 6150AD, including probe connection cables
l Simulation range approx.0.1s-1-40ks-1
l Number range approx.0.01s-1-40ks-1
6150AD-t Probe with telescopic rod:
l To detect photon radiationBeta ray probe, optional γ and
l Simulation range 0.1µSv/h-10Sv/h
l Number range 0.01µSv/h-9.99Sv/h
l energy range 65keV-1.3MeV (low dose rate counting tube)
l 65keV-3MeV (high dose rate counting tube)
l - Type Hx (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-t
l - Type H*(10) (compatible with all 6150ADn and 6150ADn/H tables): 6150AD-t/H
l - H*(10) type (only compatible with 6150ADn/E table): 6150AD-t/E
l 859.1 Wall-mounted GAMMA alarm
l for a storage typeThe device supporting the 6150AD dose rate meter has eye-catching sound and light alarm prompts, and the dose rate can be adjusted to exceed the alarm threshold.
l Installable6150AD dose rate meter and probe are attached to it (excluding 6150AD and probe), wall-mounted installation, lead-acid battery or powered by 87-250V.AC/50Hz power supply
Product consultation
- Previous article:German AUTOMESS company 6150AD-t long rod dose rate meter
- Next article:German BERTHOLD LB 111 fixed dose rate detector



Product consultation
Contact