American CIRS 062M electron density phantom
Product model:
Brief description:In the CT scanning process, to deal with the inhomogeneity of organs, it is very necessary to understand a precise relationship between CT number and electron density. The CIRS 062M electron beam phantom is such a sophisticated instrument for pre-coordination of various organ diversity and CT values.

Manufacturer strength
Manufacturer Strength
Valid warranty
Valid Warranty
Quality assurance
Quality Assurance
Products
PRODUCT CATEGORYRadiological imaging quality control equipment
American RSD phantomCRDR machine detection toolCT detection toolsDental machine testing toolsBreast testing kitDSA performance testing toolRadiotherapy and Nuclear Medicine TestingX-ray machine multifunctional quality detectorConventional X-ray photography inspection phantomUltrasound diagnostic quality control testing phantomMultifunctional dose area product meterMagnetic Resonance Machine Testing Toolsbone density phantomSimulation phantomsolid waterSensitometers and Densitometersluminance meterPortable Radioisotope Identification Device (RIID)
Detective-200 rugged, ultra-high sensitivity, portable HPGe radionuclide identification systemRADEAGLE-Cx high sensitivity, high adaptability detection unit, suitable for diversified radiation detection and nuclide identification applicationsRADEAGLET-R Rugged, lightweight, handheld radionuclide identification deviceRADEAGLE, the handheld radioisotope identification instrumentDetective-100T HPGe-based handheld radioisotope identifierMicro-Detective Ultralight Portable Handheld Radioisotope IdentifierDetective X ultra-high resolution HPGe radioisotope identification deviceDetective DX1 is a new generation, ultra-high-resolution and high-purity germanium nuclide identification instrument.Micro-Detective-HX Advanced Handheld Radiation Detection and Identification RIID- Counters, timers, rate meters and multi-channel scalers (MCS)Digital current integratoramplifierCables and accessoriespreamplifierpulse generatormulti-channel analyzerSingle channel analyzerDelays, Gates and Delay Generators, Logic Blocks and Linear GatesFast timing discriminatorTime-to-amplitude converters and calibratorsHV Bias/NIM Power Supplies and Power EnclosuresPhotomultiplier tube (PMT) base
- timing systemGammaScreen-8 Total Gamma Screen Counterα/β counterStandFAST II Standing Full Body CounterOnline monitoring systemOS1700 Tritium AdopterCompton suppression counting systemPINS3-CF Chemicals and Explosives Identification SystemCustomized systemwaste analysis systemchemical identificationnuclear safeguardshealth physics systemfood monitoring system
- FRAM plutonium and uranium isotope analysisMGA++ γ-ray isotope ratio actinide analysisNuclide Navigation-Pro, interactive nuclide map, reference softwareRenaissance whole body counter softwareANGLE advanced gamma spectrum measurement efficiency calibration softwareAlphaVision alpha spectrum measurement softwareDataMaster spectrum file format converterGammaVision gamma spectrum analysis softwareGammaVision Report GeneratorGlobal Value Productivity Suite by GammaVisionISOTOPIC gamma spectroscopy waste determinationMAESTRO Multichannel Analyzer SimulationMAESTRO-Pro Advanced Spectrum SoftwareCONNECTIONS Programmer's Toolkit
Related articles
RELATED ARTICLES
Detailed introduction
USACIRS 062M electron density phantom
Product introduction:
inIn the CT scanning process, to deal with the inhomogeneity of organs, it is very necessary to understand a precise relationship between CT number and electron density. The CIRS 062M electron beam phantom is such a sophisticated instrument for pre-coordination of various organ diversity and CT values.
062M is a disc composed of a variety of plastic water materials, including the head and abdomen. There are 8 different equivalent organ functions at 17 different positions in the scan area.
AssessmentCT value
Correct unevenness
CreateThe relationship between CT number and tissue electron content
Diagnostic energy range within tissue
USACIRS 062M electron density phantom product specifications:
Overall Dimensions Electronic Density Head Insert:180mm x 50mm (Ohms x D)
Headless insertion into electron density body:330mm x 270mm x 50mm (WxHxD)
Gravimetric electron density head insert:≈0.950 kg (2 lbs)
Headless insertion into electron density body:≈2.1kg (4.7 lbs)
Materials, Water and Tissue Equivalent Epoxies
Type 062M includes
Quantity part number description*Physical density,
G/cc electron density
X 10 square kilometers electronic/cc red
(relative to H2O)
1062 MA-01 electron density head insertion 1.029 3.333 0.998
1062 MA-02 Headless Electron Density Body Insertion 1.029 3.333 0.998
2 062A-04 lung (inhalation) equivalent
electron density plug0.20 0.634 0.190
2 062A-05 lung (expiratory) equivalent
electron density plug0.50 1.632 0.489
2062A-06 Breast (50% gland/50% fat)
Equivalent electron density plug0.99 3.261 0.976
2 062A-08 Solid Trabecular Bone (200 mg/cc HA)
Equivalent electron density plug1.16 3.730 1.117
2 062A-09 liver equivalent electron density plug 1.07 3.516 1.052
2 062A-10 muscle equivalent electron density plug 1.06 3.483 1.043
2062A-11 Fat equivalent electron density plug 0.96 3.171 0.949
2 062A-15 Solid Dense Bone (800 mg/cc HA)
Equivalent electron density plug1.53 4.862 1.456
1062A-27 Solid Dense Bone (1250 mg/cc HA)
Equivalent electron density plug1.82 5.663 1.695
1062 MA-39 water equivalent material
True water electron density plug1.00 3.340 1.000 1" caliber
1 062M-30 set of 2 feet for 062 M type
1062 M-40 type 062 M soft carrying case
1User Guide
-48 months guarantee
Optional accessories
Quantity part number description*Physical density,
G/cc electron density
X 10 square kilometers electronic/cc red
(relative to H2O)
1 062MA-07*800 mg/cc HA in water equivalent-core insert 1.53 4.862 1.456
1062 MA-12* titanium rod core insert 4.51 12.475 3.735
1062 MA-13 distance mark insertion 1.029 3.333 0.998
2 062MA-16 water equivalent insert 1.029 3.333 0.998
1062 MA-17*1000 mg/cc HA in water equivalent-core insert 1.66 5.243 1.570
1 062MA-18*1250 mg/cc HA in water equivalent-core insert 1.82 5.663 1.695
1062 MA-19*ICRU cortical bone equivalent chip*1.93 5.956 1.780
1062 MA-20*1500 mg/cc HA in water equivalent-core insert 1.99 6.134 1.837
1 062MA-21*1750 mg/ml water equivalent-chip 2.15 6.600 1.976
1062A-26 solid dense bone (1000 mg/cc HA) equivalent
electron density plug1.66 5.243 1.570
1062A-28 solid dense bone (1500 mg/cc HA) equivalent
electron density plug1.99 6.134 1.837
1062A-29 solid dense bone (1750 mg/cc HA) equivalent
electron density plug2.15 6.600 1.976