Product model:PINS3-CF

Brief description:The Portable Isotope Neutron Spectroscopy (PINS) Chemical Identification System combines chemical analysis and identification technology with the industry-leading ORTEC trans-SPEC-N high-purity germanium platform. Featuring a rugged design, PINS3-CF delivers unprecedented value through the elimination of liquid nitrogen, reduced operating costs, lightweight field-deployable equipment and built-in automatic chemical recognition capabilities.

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Related articles

RELATED ARTICLES

Detailed introduction

     PINS3-CF Chemicals and Explosives Identification System

    The Portable Isotope Neutron Spectroscopy (PINS) Chemical Identification System combines chemical analysis and identification technology with the industry-leading ORTECtrans-SPEC-N high-purity germanium platform. Featuring a rugged design, PINS3-CF delivers unprecedented value through the elimination of liquid nitrogen, reduced operating costs, lightweight field-deployable equipment and built-in automatic chemical recognition capabilities.

    In contrast to other chemical analysis and identification systems that require sampling, opening and even transportation to a controlled facility for measurement, the PINS3-CF system can perform precise measurements in containers and sealed containers in the field. Potential chemicals and explosives can now be detected in any environmental condition, even at high temperatures.

    The PINS3-CF portable chemical analysis and identification system is flexible and provides CBRNe security personnel with the information they need every day.

    The PINS3-CF system was once considered a savior in the military field. Security personnel need high security when checking the content of bombs, storage tanks, shielded containers, barrels or any unknown chemical mixture. The system provides these security personnel with the best solution through non-destructive chemical identification technology.

    The PINS3 portable chemical analysis and identification system does not require liquid nitrogen.
 

PINS3-CF Chemicals and Explosives Identification System

    ORTECPINS3-CF is a portable isotope neutron spectroscopy (PINS) non-destructive evaluation system that analyzes and provides on-site identification information on the composition of unidentified or suspicious chemicals inside unopened thick steel containers. Designed to identify chemicals within a container without the need to disassemble, touch, physically sample or open the container, the system is widely deployed in various locations as part of the nation's counter-terrorism apparatus, providing a secure method of identifying "suspicious" packaging contents.

    PINS3-CF is easy to use with the ORTECtrans-SPEC-N mechanically cooled high-purity germanium spectrometer. trans-SPEC-N has been specifically designed and tested to replace liquid nitrogen-cooled detectors currently used in neutron chemical analysis systems and provide the necessary in-situ spectral data for non-invasive chemical identification.

    PINS3-CF provides significant advantages over previous liquid nitrogen systems by eliminating the logistical and safety issues associated with liquid nitrogen storage and transportation, equipment handling, maintenance and training.

    PINS application

    · Ammunition - artillery, rockets, explosives, landmines.

    ·Containers - cylinders, tanks, bags, briefcases, parcels.

    ·Chemicals - chemical warheads, explosives, gases, smoke.

    PINS overview

    The Portable Isotope Spectroscopy (PINS) Chemical Identification System non-destructively identifies hazardous compounds and mixtures. There is no need to open or touch the test object, greatly increasing safety. As shown in the figure, PINS tests objects with neutrons, which excite the interior of atomic nuclei, causing the excited nuclei to produce gamma rays. Each chemical element's gamma rays have a unique energy intensity pattern, or spectrum, so by analyzing the gamma ray spectrum, PINS software can identify chemical elements within a test object and determine whether the object contains chemical warfare agents, fillers (such as sand), or smoke-producing chemicals.

    Working principle

    PINS3-CF uses neutrons produced by the fission of the radioactive isotope californium-252 (Cf-252). The standard PINS3-CF5 microgram Cf-252 source produces 10 million neutrons per second. The source emits neutrons in all directions, with approximately 1,000 neutrons striking each square centimeter of the test object's surface per second. Because neutrons are a highly penetrating form of radiation, most neutrons will pass through the test object's outer shell and interact with the chemicals inside.

    Neutrons from a source excite the nuclei they encounter through inelastic scattering or neutron capture. In either case, excited nuclei decay to their ground state by emitting gamma rays, which are characteristic of emitting nuclei. That is, gamma ray energy and intensity often vary greatly from one type of nucleus to another. For example, hydrogen nuclei emit 2.2-MeV gamma rays when bombarded by neutrons, while phosphorus nuclei emit 1.3-MeV gamma rays.

    Neutron-induced gamma rays are measured by a high-purity germanium (HPGe) spectrometer and classified into spectra by the spectrometer electronics. By analyzing the spectrum, the chemical elements excited by the neutrons can be determined and the chemicals within the test object can be identified.

    Run PINS

    Developed specifically for field deployment, PINS3-CF is portable and rugged. Its components include a mechanically cooled spectrometer with an integrated multi-channel analyzer, a small radioactive californium neutron source, a detector stand and shield, and a laptop computer to provide the user interface. Custom software displays data in real time as it is collected and provides comprehensive monitoring and analysis options.

    Laptop used as PINS3-CF control panel. The computer allows the user to initialize the instrument, start and stop data acquisition by the gamma-ray spectrometer, display and analyze the resulting gamma-ray spectrum. The connecting cable, 82 feet (25 meters) long, keeps the computer at a safe distance from the radiation isolation zone and provides communication between the computer and the gamma-ray spectrometer.

    trans-SPEC-N mechanically cooled high-purity germanium spectrometer

    Unlike the liquid nitrogen-cooled HPGe spectrometer used in previous PINS systems, PINS3-CF uses trans-SPEC-N to mechanically cool the HPGe spectrometer, which does not require liquid nitrogen. The electrical energy required to cool the spectrometer detector is approximately 30 watts. The trans-SPEC-N lithium-ion battery keeps the detector cool for 10 to 12 hours, and the external battery supports "hot swapping" for extended use of the instrument in the field. trans-SPEC-N provides a flexible, modular solution to support on-site detection of chemicals and explosive threats with the following features:

    ·LN2-free - Miniature, high-reliability, "always-on" Stirling cycle refrigerator does not require liquid nitrogen; the detector element is packaged in a high-reliability, low-loss, all-metal sealed cryostat.

    · High sensitivity - large (>50% relative efficiency) HPGe detector.

    ·High Stability - Digital electronics provide solutions for troublesome analysis under harsh conditions.

    ·Bright and clear - VGA resolution display and touch-sensitive operation screen.

    ·Integrated integrated design - sturdy and compact, no interconnection required - easy to install and use.

    ·Intelligent - nuclide identification and activity calculation for nine regions of interest (ROI).

    ·Reliable connection - USB2.0 and wireless.

    · 802.11 communications, built-in GPS and secure digital input/output (SDIO) storage of collected spectra.

    Flexible - Works with a variety of power sources including internal battery, auxiliary external battery, car battery (any 12VDC) and line power; switches automatically.

    Automated analysis of chemicals

    The PINS data acquisition program records and displays spectral measurements from trans-SPEC-N. It also analyzes spectra recorded every 10 seconds, fits peaks of interest, recalibrates the energy scale and performs chemical analysis. The new chemical analysis method is based on the decision tree logic shown and identifies chemicals within the object being measured. The new probabilistic method traces each path in the decision tree and assigns a score to each chemical it may contain. Chemicals with a score are selected as included chemicals.

    New chemical analysis methods are faster, more accurate, and more easily expand the list of chemicals that PINS can automatically identify. Currently, PINS automatic analysis software can identify the following chemicals.
 

chemical warfare agents experience filler
BR-2 Bleach
CG POP
CK sand
GB water antifreeze
HD smoke chemicals
HN FM
VX FS
WL HC
riot control agent WP
CA fried yao
CNB CNS

    Gamma-ray HPGe spectrometer

Model ORTEC trans-SPEC-N
relative efficiency >50% typical (ANSI/IEEE 325-1996)
energy resolution <1600 eV @ 122 keV and ≤2.5 keV @ 1332 keV (FWHM guaranteed with optimal settings and detector type)
Multichannel Analyzer (MCA) Built-in digital signal processing MCA
MCA channel Up to 16k
Size 15.5"L x 6.55"W x 13.75"H (39.4cmL x 16.3cmW x 34.9cmH)
weight 24.4 lbs (11.1 kg)
Input power 10–17 V DC @ 30 Watts
Internal battery life For cold detectors, >3 hours at 77°F (25°C)
external battery For cold detectors, extended operating time to 12 hours at 77°F (25°C)
Initial cool down time <10 hours at 77°F (25°C)

    laptop

Model Panasonic Toughbook CF-31
operating system Microsoft Windows 7
Hard drive capacity 320 GB
Battery working time 12.5 hours
Charging time 4.5 hours
Size 11.9" x 11.5" x 2.9" (30.2cm x 29.2cm x 7.3cm)
weight 8.2 lbs. (3.7 kg)
Operating temperature range 14–22

    Cf-252 neutron source
Model Frontier Technology Corporation Company Model 100
radioactive isotopes Calf-252
Source quality 5 micrograms
source activity 2.5 millicuries, 92.5 megabecquerels
Neutron Maxwell, temperature spectrum Parameter = 1.42 MeV
average neutron energy 2.1 MeV
structure Solid Metal - Cermet Source, Dual Stainless Steel Package
special form certification U.S. Department of Transportation (US DOT)
shipping container Frontier Technology Corporation Model 50240 (5-gallon bucket)
Shipping container certification US DOT type A, specification 7A

PINS3-CF Chemicals and Explosives Identification System


Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7