Detective X Portable High Purity Germanium Gamma Spectrometer

Survive in development, continuously optimize, and promote rapid development of enterprises with good reputation and scientific management

Detective X Portable High Purity Germanium Gamma Spectrometer image

Detective X Portable High Purity Germanium Gamma Spectrometer

Product model:

Brief description:How to improve the “gold standard” for nuclear threat detection and identification? ORTEC’s new Detective

  • Manufacturer strength

    Manufacturer Strength
  • Valid warranty

    Valid Warranty
  • Quality assurance

    Quality Assurance

Products

PRODUCT CATEGORY

Related articles

RELATED ARTICLES

Detailed introduction

Detective XPortable high-purity germanium gamma spectrometer

 

How to improve nuclear threat detection and identificationThe "gold standard"? ORTEC’s new Detective

Detection and identification functions

· biggerHPGe crystal, efficiency ratioMicro-Detective-HXThree times higher.

· Improved algorithm that increases detection probability.

· including new radiopharmaceuticalsA nuclide library of 175 radionuclides.

· Better long-distance detection and identification capabilities.

Operational improvements

· Designed for harsh environments (compliant withDurable instrument designed for IP65 standard).

· Significant weight reduction (approx.Detective-EX-100Thalf).

· Doubled battery life and hot-swappable support.

· new typeLi6/ZnS Neutron Detector Module (NDM) without 3He.

· Larger display, easy to read in sunlight.

quality improvement

· The new Stirling refrigerator has greater cooling capacity and longer mean time to failure.

· Lighter and stronger with an extremely tough polycarbonate shell.

Enhanced connectivity options

· System includes built-in Ethernet connectivity (RJ45)。

· with computerUSB connection is plug and play.

· USB flash drive can store > 100,000 spectra.

· Cell phone interconnection and instrument control supportiOS, Android and Windows platforms.

· WiFi and Bluetooth are standard on the Detective X.

Detective X Features

· Portable - Lightweight, can be operated with "one hand", and has GPS positioning function. Detective X is approximately 50% lighter than the industry-leading ORTEC Detective-EX-100T.

· Extremely strong - Designed for military use. Withstands temperatures ranging from -20°C to +50°C. IP65 protection level (waterproof, dustproof) and anti-fall design.

· Zhuo Yue’s algorithm - Excellent detection and nuclide identification capabilities and lower false alarm rate compared to other systems. More than 175 radionuclides are stored in the library.

· automatic calibration - Continuous real-time detector stabilization continuously calibrates the instrument.

· Enhanced communication capabilities - Equipped with IEEE 802.11a/b/g/e/i/h/j standards and IEEE 802.11n wireless, wired Ethernet, USB, Bluetooth, and can be remotely controlled through smartphones (Android, iOS and Windows PC). Remote control and monitoring can be easily accomplished from the central control room.

· OptionalLi6ZnS neutron detector (without 3He).

· Large capacity mobileUSB flash drive.

· Easy to operate: bright, clear, sunlight-readable display touch screen and intuitive menus.

· Dual batteries (hot-swappable) provide up to10 hours.

· LargeHPGe crystal (65 mm x 50 mm).

Detective X algorithm
ExceptIn addition to the inherent selectivity of the HPGe detector type, the ultimate performance of Detective X in terms of identification fidelity also depends on the software algorithm. ORTEC licensed the original Lawrence Livermore RadScout algorithm in 2003 and made numerous improvements to it over the years. For example, as part of the DHS/DNDO HPRDS program, ORTEC developed the Advanced HPRDS RIID (Micro-HPRDS) from 2008 to 2010. Advances in this algorithm greatly enhance nuclide identification and minimize false alarms. Over the past 10 years, ORTEC has participated in various testing events sponsored by DNDO, DoD/DTRA, IAEA, and the U.S. Department of Energy National Laboratories to continue to improve algorithms and upgrade radionuclide libraries. Detective X uses algorithms and a large 65 mm x 50 mm crystal, making it the most sensitive and accurate RIID on the market. The probability of false positives and false negatives is further reduced. If decisions need to be made about potential threat sources, backup experts also need HPGe spectrum. It is widely considered the "gold standard".

Detective X Hardware Overview
ORTEC has over 12 years of experience in HPGe RIID. Input from users around the world has been incorporated into Detective X. Detective X is compact, lightweight and has rugged hardware. The 40% high-efficiency (65 mm x 50 mm) HPGe crystal in the "Ultra High Vacuum" cryostat is cooled by an integrated low-power Stirling refrigerator. The new refrigerator equipped with Detective X can provide greater cooling capacity. The ultra-high vacuum cryostat contains no conventional molecular sieves, allowing the instrument to be turned on or off at any time during the detector cooling or rewarming cycle without any risk. ORTEC is the only manufacturer to offer this feature in a handheld HPGe RIID.

Built-in numbersThe MCA system and a dedicated data processor will be delivered with the product. Detective X features a bright VGA resolution display and touch-sensitive operation screen that is readable under direct sunlight. The operation of Detective X is very intuitive. Radionuclide gamma-ray spectra can be displayed and manipulated (e.g., vertical scale, zoom) similar to traditional multichannel analyzers. Gamma count rate, neutron flux and gamma dose rate are displayed continuously.

UseDetective X: Overview

· The high-resolution, sunlight-readable color touch screen is designed for operating the system and entering data such as passwords and alarm limits.

· The three physical buttons on the device (Power, Navigate (N) and Select (S)) can also be used for inspection and spectrum collection operations.

Audiovisual feedback:

· Bluetooth headsets can be used for audio alarms. The handle provides a vibration alarm.

· The top of the screen starts withmrem/hr (or μSv or μGy) displays the current dose rate. The corresponding icon shows whether the instrument has GPS activated (green) or inactive (red). The icons also show the status of MFK, Bluetooth, LCX mode stabilizer (when disabled) and WiFi (connected or not connected).

· When radiation is detected and recognized, the recognition results will be displayed in the real-time recognition area of the screen. This area lists the names of any radioactive isotopes currently detected.

operating mode

Detection mode operation
Detection mode is used to locate and identify sources. In this mode, the instrument continuously"Search" but no data is stored. The "Detection Mode" screen will display the detector count rate and dose rate. It is also in search mode and monitoring mode.

The "Detection Mode" screen displays a strip chart of "Signal Index" and "SNM Index" in the middle of the screen. The strip chart updates every half second. They are real-time indicators of the presence of radioactive material. The strip chart sometimes shows an increasing trend before the recognition results are displayed on the screen.

Inspection always starts with a measurement in inspection mode.Detective X is set to start automatically in detection mode.

Identify mode operations
This mode identifies radionuclides by counting a target object or area from a fixed location over an extended period of time. Collect data for a preset time period or before collection is stopped.

The recognition pattern can be found inOperate in "Single" spectrum mode or "Multi-spectrum analysis" mode. The mode is selected by the administrator. Single spectrum mode will initiate spectrum collection and perform radionuclide identification as the spectrum is collected. In multispectral mode, background, known and unknown spectra are collected, automatically packaged and sent to the control center.

The default time is real time. During this period, radionuclidesThe ID is displayed on the screen as the nuclide name. The operator can view the spectrum in real time or have the screen display the ten strongest gamma ray energies in the spectrum during identification.

Detective X and background radiation - no more NORM alerts
Unless the standard material is significantly higher than the stored background, otherwiseDetective X can identify and suppress NORM identification results from background measurements saved on the instrument.

Detective X and Digital Stabilization - Best Performance
Although the digital germanium spectrometer is a highly stable instrument under changing temperatures,Detective X can even be used in extreme conditions. The automatic gain stabilizer system will "lock on" the natural background K-40 peaks (if present) to ensure "perfect" calibration even under harsh processing conditions. The stabilizer is very "smart". If the K-40 is not found in the spectrum, the gain stabilizer will be turned off. Additionally, users can choose to disable the spectrum stabilizer and proceed directly to ID measurements to minimize setup time in mission-critical scenarios.

Detective X has a very comprehensive list of nuclides. A subset of the entire nuclide library is the default "threat isotopes"; they are marked red. Advanced users are able to add any nuclide marked green to the list of red threat isotopes. The color coding in the table shows the default background screen colors and visual alerts that will be displayed when the instrument encounters these nuclides.

2235 keV peak exists
AM-241
Am-241 (shielded)
Am-241 (unshielded)
neutron
Cf-252/Cf-249
Enriched uranium
Geiger-Miller CR
HEU
neutron
Neutrons on Al
neutrons on boron
Neutrons on Fe
neutrons on hydrogen
Neutrons on Pb
neutron or heliumγ
NP-237
Pu-238
Pu-239
Radiation detected
U-232
U-233
U-235
U-238
unknown peak
unknown/β emitter
1001 keV peak exists
186 keV peak exists
2614 keV peak exists
356 keV peak exists
375/414 keV peak exists
662/722 keV peak exists
Ac-225
Ac-227
Ag-110m
Ar-41
As-72
As-74
At-211
Au-198
Ba-133
Ba-140
Be-7
beta emitter
Bi-207
Bi-212 (Th232/U232 daughter)
Bi-214 (Ra226 daughter)
Br-76
Br-76 (shielded)
Br-76 (tightly shielded)
Br-77
Ca-47
Cd-109
Cd-115
Ce-139
Ce-141
Ce-144
Cm-242
Cm-243
Cm-244
Co-56
Co-56 (shielded)

Co-55
Co-57
Co-57 (shielded)
Co-58
Co-60
Cr-51
Cs-131
Cs-134
Cs-137
Cu-64
Cu-67/Ga-67
Eu-152
Eu-154
Eu-155
Eu-156
Fe-18
Fe-59
Ga-64
Ga-64 (shielded)
Ga-67
Ga-67 (shielded)
Ge-68/Ga-68
Gd-153
Gd-159
Hf-181
Hg-203
Ho-166m
Ho-166m (shielded)
Ho-166
I-123
I-123 (shielded)
I-124
I-125
I-126
I-126 (shielded)
I-131
I-131 (shielded)
I-132
I-133
I-134
I-135
In-111
Ir-192
Ir-192 (shielded)
Ir-194 (shielded)
K-40
Kr-87
Kr-88
Kr-88 (shielded)
La-138
La-140
Lu-172
Lu-176
Lu-177
Lu-177m
Mn-52
Mn-54
Mn-56
Mo-99
Na-22
Na-24

Nb-92
Nb-94
Nb-95
Nb-96
Nb-96 (shielded)
Nd-147
Os-194/Ir-194
Pa-231
Pb-203
Pd-103
Po-210
Pr-144
Ra-223
Ra-226
Rb-83
Rb-86
Rh-105
Ru-97
Ru-103
Ru-106/Rh-106
Sb-124
Sb-124 (shielded)
Sb-125
Sb-127
Sc-46
Se-75
Sm-153
Sm-153 (shielded)
Sn-113
Sr-82/Rb-82
Sr-85
Sr-85/Kr-85
Sr-89
suspicious neutron
Ta-182
Tc-96
Tc-99m
Te-132
Tl-201
Tl-200
Tl-202
Tl-204
Th-229
Th-230
Th-232
Tm-170
Tm-171
V-48
W-187
W-188/Re-188
Xe-127
Xe-131m
Xe-133
Xe-133m
Xe-135
Y-88
Y-91
Yb-169
Zn-65
Zn-62
Zr-95

The detection mode user interface isA simple and easy to use mode for Detective X. It is specially designed for customers who may not use the instrument frequently, need to perform nuclide screening measurements quickly, and need to report data to foreign countries.

The detection mode in Detective X software integrates the following functions:

· An extremely simple and easy-to-use user interface, even if you are not an expert in energy spectroscopy, you can easily get started.

· You can start, pause, and restart a measurement at any time. This function can save accumulated data, and users can perform other operations.

· Help users target their main concerns (Item of Primary Concern) determines the optimal measurement distance.

· A warning interface will remind the user to shut down the Stirling refrigerator before shipment.

· More simplified touch screen buttons for ease of use.


Detection mode is an extremely easy-to-use and simple-to-operate mode. It is especially suitable for law enforcement officers in some government law enforcement departments who may not use such instruments every day like professional laboratory analysts..

Detection mode minimizes the chance of errors. Especially when operators are performing multiple tasks simultaneously, primary concerns can be quickly and accurately assessed (Item of Primary Concern).

Due to the extremely simplified user interface, detection mode can greatly simplify the training of relevant operators.

detector

Nuclide identification

P-type high-purity germanium (HPGe) crystal, coaxial structure. Nominal crystal size: 65 mm diameter x 50 mm long.

Cryostats and Refrigerators

"Ultra-high vacuum" cryostat, and highly reliable low-power Stirling refrigerator. The cryostat is designed so that the user can turn Detective This feature significantly increases system availability during measurement activities.

Cooling time

High reliability chillers are designed for continuous operation. Between measurements, the instrument is powered by DC power, a car battery, or other device. The initial cooling time depends on the ambient temperature, butTypically 6 hours at 25°C.

gamma dose rate detector

Three detectors can measure gamma dose rates ranging from 0.1 mR/h to 2000 mR/h. The instrument can automatically switch between high-purity germanium detector, low-range GM tube and high-range GM tube. The dose rate is guaranteed to be accurate±10%, excluding propagation of systematic errors,ExampleSuch as the accuracy of calibration standards. For customers using certified dose rate calibration equipment, the Dose Rate Wizard allows the system to perform dose rate calibration. For customers requiring dose rate calibration guaranteed by the manufacturer,ORTEC provides dose rate calibration services.

Gamma energy range

Detective X and Detective X-N = 40 keV to 3 MeV.
Detective X-8 and Detective X-8-N = 40 keV to 8 MeV.

Neutron Detector Module

The optional neutron detector is bulk lithium fluoride-6/Zinc Sulfide (Li6F/ZnS) detector, compliant with ANSI N42.34 2015 standard.

Hardware

numbersMCA and data processor

Display:4.3-inch WQVGA (480 x 272 pixels) Sunlight-readable, touch-sensitive, can be operated with fingers or stylus.

Data processor:FREESCALE I.MX535, operating frequency 1 GHz.

data storage

Media: Store to internalRAM and USB flash drive. The instrument comes with a 16 GB flash drive capable of storing over 100,000 spectra.

File format:ANSI N42.42。

computer interface

USB and Ethernet TCP/IP v4 connections via standard RJ45 Ethernet connection (10/100Base-T - 10/100Mbps, adaptive). Ready to use with MFK (Mobile Field Kit for DoD users), ORTEC GammaVision、Used with iOS devices and Android devices. Wi-Fi (IEEE 802.11a/b/g/e/i/h/j standards and IEEE 802.11n) communications. Wireless mobile MCB server software.

wireless connection

IEEE 802.11a/b/g/e/i/h/j standards and IEEE 802.11n wireless and Bluetooth. All current protected access protocols are supported, including WPA and WPA2.

GPS (Global Positioning System)

The instrument has built-inGPS (Global Positioning System). Location information associated with measurements is optionally stored in N42 files.

RF safety

if For security reasons, Detective X needs to be used in an environment without radio frequency signals. The RF Secure option can disable WiFi, Bluetooth and GPS signals. If you need this function, add "DETECTIVE-X-OPT-RFSECURE" to the accessories list.

numbersMCA, internal memory with multiple spectral data

Digital noise suppression:"LFR filter".

Conversion gain:16k channels.

Maximum number of stored scores: No limit on mobile storage.

Physical specifications

Maximum dimensions

Maximum overall dimensions for each model and configuration (includes handle and germanium detector end cap):
DETECTIVE-X and DETECTIVE-X-8 without straps L 15.5 in x W 5.6 in x H 8.3 in (L 39.5 cm x W 14.3 cm x H 21.0 cm)
DETECTIVE-X and DETECTIVE-X-8 with shoulder strap L 15.5 in x W 6.4 in x H 8.3 in (L 39.5 cm x W 16.3 cm x H 21.0 cm)
DETECTIVE-X-N and DETECTIVE-X-8-N with neutron detector (with or without shoulder strap) L 15.5 in x W 6.4 in x H 8.3 in (L 39.5 cm x W 16.3 cm x H 21 cm)

weight

15 lbs (gamma only). 17 pounds (gamma/neutron).

internal battery

2 rechargeable lithium-ion batteries. Nominal 98 Wh per block. When the HPGe detector is cold, the battery life is over 8 hours at 25°C. Charging time <4 hours. The internal battery is easily replaced.

external battery

Battery life can be extended indefinitely by using an optional external battery pack. External jun battery (model2590) weighs less than 3.25 pounds and has extended battery life to >16 hours.

Input power

from batteries or DC power (including universal mains power)12 to 17 V DC.

Power consumption

During cooling and battery charging:<100 watts. The battery is <35 W cold when fully charged.

Scope of work

Temperature:-20°C to 50°C.

Relative humidity:95%, no condensation.

Instrument housing

IP65 sealing prevents dust and water ingress. All jacks are sealed with rubber plugs (interfaces, memory cards, etc.)

Communication software

Detective X is a member of the ORTEC CONNECTIONS family. Remote MCA control, even over the network, via the MAESTRO-PRO Advanced Spectrum SoftwareRealize.

Multiple spectra can be passedThe USB connection is bundled from the instrument controller to the external PC. When connected to a laptop or PC, Detective X appears as a flash drive. Exported files are in N42 format and can be used by most expert team programs such as CAMBIO and PeakEasy as well as ORTEC software products such asGammaVision) read.

Detective Detective X can be easily used with MFK software, ORTEC GammaVision software, iOS devices (iPhone®, iPAD) and Android® devices.

moveMCB server

moveThe MCB server software application enables Detective X to interface with ORTEC software applications such as MAESTRO, GammaVision andDetective-Remote®) for wired or wireless communications.

The user can use the optionalA11Toolkit to develop your own applications.

Product consultation

Message box

Please enter the calculation result, such as: three plus four = 7

After submission, we will receive your requirements. You can also download the requirement file or call 021-20989890 directly.